Thread leadwires and safety cable
through the downrod
7
Set dip switches on the Remote Transmitter and Remote
Receiver to the same settings. This must be done so the
units will communcate properly. If you have other fans you
can set to control from one transmitter by setting both
receivers the same as the transmitter. If you have more
than one fan with remote. You can set the dip switches to
different positiosns to have seperate control.
Remote Transmitter Dip swtiches
Remote Receiver Dip switches
15
Install remote receiver into the
mounting bracket.
16
Ready for wiring.
17
Make sure the studs protruding from the
bottom of the Mounting bracket are
installed with threads all the way through
the bracket.
12
Loosen the 2 screws on the yoke to
allow down rod to slip into yoke.
8
Insert down rod into yoke on top of
the fan body. Align the hole in the
down rod with the hole in the yoke.
Insert the Pin through the yoke and
down rod until the point appears on
the other side.
9
Install keeper pin.
10
Tighten the 2 set screws on the
yoke, once the down rod is in place.
11
Hang assembled fan from the mounting bracket
installed to ceiling in previous step. Make sure the
fan is hanging straight. Rotate fan until the tab on
the Mounting bracket engages the slot on the
Downrod Ball. This must be done to prevent the fan
body from rotating when the blades are in motion.
13
Fan and light kit combinations over 35 lbs,
in both flush and downrod mode the safety
cable must be installed into the house struc-
ture beams using the 3” lag screws,washers,
and lock washers. provided. Make sure that
when the safety cable is fully extended the
lead wires are longer than the cable and no
stress is placed on the lead wires.
14
Safety cable installation
safety cable
lag screw
safety
cable
3” lag
screw
lock
washer
washer
Make wiring connections as indicated above.
White from fan to white from remote marked
N. Blue from fan to blue from remote marked
light. Black from fan to Black from remote
marked L. White from house to white from
remote marked AC N . Black from house to
Black from remote marked AC L. Connect all
green ground wires to Grounded wire from
House.
18