Cautions and Warnings

Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses, Stepladder and Wire Strippers

WARNING:

 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

 READ AND SAVE THESE INSTRUCTIONS

Customer Service

800-969-3347

Customer Service Center

7400 Linder Ave.

Skokie, IL 60077

www.montecarlofans.com

2

© 2022 Monte Carlo Fan Collections

3/2022

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 

70) including fire-rated construction.
Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.
After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor 

on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be 

turned upward and pushed carefully up into the outlet box.

WARNING:

 Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting 

means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a 

prominent warning device, such as a tag, to the service panel.
Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet 

from the floor to the trailing edge of the blade.

WARNING:

 To Reduce The Risk Of Fire, Electric Shock, or Personal Injury, Mount To Outlet Box Marked “Acceptable for Fan Support of 

15.9 kg (35 lbs) or less” And Use Mounting Screws Provided With The Outlet Box.

CAUTION

: For Compliance with Local Codes and Regulations, If Installing The Secondary Support Safety Cable in the U.S., Do Not Remove 

Knockouts In The Outlet Box. Mount the secondary support safety cable through the reserved nail/screw hole on the outlet box to the 

building structure (or the ceiling joist).

WARNING:

 To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning.  Do 

not insert foreign object between rotating blades.
Attach the mounting bracket using only the hardware supplied with the outlet box.

WARNING:

 To reduce the risk of fire or electric shock, do not use this fan with any unverified solid state fan speed control device, or 

variable speed control.
If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
Never place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating 

equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the 

American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

CAUTION:

 To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit. 

All set screws must be checked and tightened where necessary before installation.

 

Содержание 5LD52 D Series

Страница 1: ...ER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 5LD52XXXD Series Fan CUL Model NO 5LD52XXD 7 5 kg 16 5 lbs Owner s Guide and Installation Manual ...

Страница 2: ... choose allows the fan blades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade WARNING To Reduce The Risk Of Fire Electric Shock or Personal Injury Mount To Outlet Box Marked Acceptable for Fan Support of 15 9 kg 35 lbs or less And Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regu...

Страница 3: ...ox will cause the fan to wobble Install the mounting bracket onto the outlet box Partially loosen the two screws on the outlet box attach the mounting bracket onto the outlet box by sliding it over the two screws as shown in the illustration Have the mounting bracket in position and tighten the set screws Partially loosen downrod set screws from yoke at top of motor assembly Remove preassembled cr...

Страница 4: ...ided as indicated above White from fan to White Neutral from house Black and Blue from fan to Black Live from house Connect all green grounded wires to Grounded wire from House Make sure that no filaments are outside of the wire connectors After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet b...

Страница 5: ...e Knockouts In The Outlet Box Make wiring connections using wire connectors provided as indicated above White from fan to White Neutral from house Black and Blue from fan to Black Live from house Connect all green grounded wires to Grounded wire from House Make sure that no filaments are outside of the wire connectors After making the wire connections the wires should be spread apart with the grou...

Страница 6: ... by 3 blade screws and washers provided Tighten screws securely Repeat this process for remaining blades Remove shipping stabilizers from motor assembly Install the blade assembly to motor using the preinstalled screws Tighten screws securely Repeat this process for remaining blade assemblies Remove switch housing cap by removing the set screws Keep screws Remove the tap from bottom of the switch ...

Страница 7: ...n does not rub against bulb during operation Install the rubber washer and hex nut to hold the glass DO NOT OVER TIGHTEN IT Align hole in center of final cap with thread rod allowing pull chains to come through appropriate holes in the final cap and push up Thread center pull chain through hole in finial and secure glass to light fixture by tightening the finial DO NOT OVER TIGHTEN the finial as g...

Страница 8: ...ounting bracket or mounting plate are tightened securely to 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceiling Keeping measure within 1 8 rotate the fan until the next blade is positio...

Страница 9: ...Mar 2022 ...

Отзывы: