background image

© 2013 Monte Carlo Fan Company

11/15/2013

4

Make wire connections to power source using wire nuts
provided.  Make sure that no filiments are outside of
the wirenut. After making the wire connections, the
wires should be spread apart with the grounded con-
ductor and the equipment-grounding conductor on one
side of the outlet box and ungrounded conductor on the
other side of the outlet box.  

11

Pass leadwires  and safety cable through

the canopy.

Remove side covers from canopy exposing

4 holes.  2 closed holes and 2 open “L”

shape holes.

17

16

Lift Conopy allowing the 2 studs to

protrude through the canopy.  

12

Next lift the cover ring and install knurled

nuts as shown.  Tighten the knurled nuts

securely.  The canopy should adjust for

any irregularity in the ceiling or Outlet

box.

13

Connect black and blue wire from fan to Black or (Hot)
wire from house.  Connect White wire from Fan to White
(Neutral) wire from house.  Connect Ground leads from
mounting bracket and downrod to Ground lead from
house.  

Refer to Safety Tips section of manual.

10

Cover Ring

House

Fan

Blue 

Black

White

Green

Black

White

Ground

Go to step

25 to finish

installation.

Remove the 2 yoke set screws as shown

above.

Flush Mount Installation

14

Remove the 3 yoke screws with the

keyslot holes and save.

15

Содержание 5HM52XXN Series

Страница 1: ... to this card and retain as your proof of purchase DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS To register your fixture please visit our website www montecarlofans com 5HM52XXN Series Fan Total fan weight UL Model No AC 552 6 52 kgs 14 34 lbs ...

Страница 2: ...nd Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Re move Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury ...

Страница 3: ...he other side Install the Keeper Pin Tighten the 2 Set screws on the Yoke once the downrod is in place Check motor for shipping stabilizers and re move if present Tread leadwires and safety cable first through the canopy disk Canopy and lastly downrod 3 2 1 5 6 4 Canopy disk Downrod Canopy Yoke Cross Pin Keeper Pin Hang assembled fan from the mounting bracket in stalled to ceiling in previous step...

Страница 4: ... 17 16 Lift Conopy allowing the 2 studs to protrude through the canopy 12 Next lift the cover ring and install knurled nuts as shown Tighten the knurled nuts securely The canopy should adjust for any irregularity in the ceiling or Outlet box 13 Connect black and blue wire from fan to Black or Hot wire from house Connect White wire from Fan to White Neutral wire from house Connect Ground leads from...

Страница 5: ...using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded con ductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 23 Connect black and blue wire from fan to Black or Hot wire from house Connect White wire from...

Страница 6: ...oblems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is posi tioned for measurement Repeat for each blade If all blade levels are not equal you can ad just blade levels by the following procedure To adjust a...

Страница 7: ...Jul 2013 Update CUL regulation Aug 2013 Update Fan weight Nov 2013 5HM52XXN ...

Отзывы: