background image

1.Check main and branch circuit fuses or circuit breakers.

2.Check line wire connections to fan and switch wire connections in switch housing.

CAUTION:  Make sure main power is turned off

1.Check to make sure all screws in motor housing are snug (not over tightened).

2.Check to make sure the screws which attach the fan blade holder to the motor are tight.

3.Check to make sure wire nut connectors in switch housing are not rattling against each

other or against the interior wall of the switch housing.

CAUTION:  Make sure main power is turned off before entering switch housing.

4.Some fan motors are sensitive to signals from Solid State variable speed controls.  

DO NOT USE a Solid State variable speed control.

5.Allow "break-in" period of 24 hours.  Most noises associated with a new fan will disappear

after this period.

1.Make sure that the ridge of the canopy engages the notch in the downrod ball. 

2.Check that all blades are screwed firmly into blade holders.

3.Check that all blade holders are tightened securely to motor.

4.Make sure that canopy and mounting bracket are tightened securely to ceiling junction box

and junction box is mounted firmly to ceiling joist.

5.Most fan wobble problems are caused when blade levels are unequal. Check this level by

selecting a point on the ceiling above the tip of one of the blades. Measure this distance

from blade tip to ceilng. Keeping measure within 1/8", rotate the fan until the next blade is

positioned for measurement. Repeat for each blade. If all blade levels are not equal, you can

adjust blade levels by the following procedure. To adjust a blade tip down, insert a washer

(not supplied) between the blade and blade holder at the screw closest to the motor. To

adjust a blade tip up, insert washer (not supplied) between the blade and blade holder at

the two screws farthest from the motor.  Reverse the position of the washer if blades mount

from top of blade.

6.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can

redistribute the weight and possibly result in smoother operation.

1.Check wire from fan to make sure it is connected to hot wire from house.

2.Check for loose or disconnected wires in fan switch housing.

3.Check for loose or disconnected wires in light kit.

4.Check for faulty light bulbs.

CAUTION:  Make sure main power is turned off before entering switch housing. 

2. If fan sounds noisy:

1. If fan does not start:

3. If fan wobbles:

4. If light does not work:

Trouble Shooting

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation,

or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults,

please check this Trouble Shooting Chart. If a problem cannot be remedied, or you are experiencing difficulty

in installation, please call our Customer Service Center at the number printed on your parts list insert sheet. 

Warning: Before servicing or cleaning unit, Switch power off at Service panel and lock service dis-

connecting means to prevent power from being switched on accidentally.  When the service dis-

connecting means cannot be locked, securely fasten a prominent warning device, such  as a tag,

to the service panel.

Customer Service Center:

740 S.W. Loop 820, Suite 110

Fort Worth, Texas 76115

1-800-519-4092

Содержание 5CE52 Series

Страница 1: ...Quality Ceiling fans Owner s Manual Ceiling Fan Installation Instructions For 5CE52 Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weight ...

Страница 2: ...b or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equip ment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before ...

Страница 3: ...o ceiling in previous step Make sure the fan is hanging straight Rotate fan until the tab on the Mounting bracket engages the slot on the Downrod Ball This must be done to prevent the fan body from rotating when the blades are in motion Re install safety bar removed in step 3 by placing safety bar on screws sliding into place and tightening the 2 screws 17 14 Thread wires and safety cable through ...

Страница 4: ...ox and ungrounded conductor on the other side of the outlet box 19 For pullchain controls follow diagram above Make sure that all exposed wiring is secured inside wire nuts Note Wires from house may vary in color and may not include ground wire After wiring is complete gently push wires into junction box with wire nuts pointing upward Refer to point 3 of safety tips 20 House Fan Black White Green ...

Страница 5: ...evels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interc...

Отзывы: