background image

19

18

Remove every other screw as 

circled  and  save  screws  for 

later use. 

Pass  leadwires  and  safety 

cable through canopy.

Re m ove   c a n o py   b o t t o m   c ove r 

f r o m   c a n o p y   b y   t w i s t i n g 

counterclockwise.

Remove  set  screws  and  pins  from 

yoke as inset shown.  

 

20

Place  the  canopy  over  the  yoke 

screws,  aligning  the  large  holes 

from  the  canopy  over  the  screws 

on the yoke. Re-install the 3 screws 

removed  in  step  19  to  secure  the 

canopy. 

22

Hang  fan  from  mounting 

bracket  by  the  hands  free 

hook  into  a  closed  hole  on 

the edge of the Canopy.

26

Lift  fan  to  mounting  bracket, 

aligning the “L” shape holes with 

the  scresws  on  the  mounting 

bracket.  Turn the fan  clockwise 

to  lock  in  position.  Re-nstall 

the  2  canopy  mounting  bracket 

screws removed in step 21. 

24

Make  wiring  connections  as  indicated 

above.Connect black and blue wire from 

fan  to  Black  or  (Hot)  wire  from  house.  

Connect  White  wire  from  Fan  to  White 

(Neutral)  wire  from  house.    Connect 

Ground  leads  from  mounting  bracket 

to  Ground  lead  from  house.    Refer  to 

Safety Tips section of manual.

25

Make  wire  connections  to  power  source  using 

wire  nuts  provided.    Make  sure  that  no  filiments 

are outside of the wirenut. After making the wire 

connections,  the  wires  should  be  spread  apart 

with the grounded conductor and the equipment-

grounding  conductor  on  one  side  of  the  outlet 

box and ungrounded conductor on the other side 

of  the  outlet  box.  The  splices  after  being  made 

should be turned upward and pushed carefully up 

into the outlet box. 

21

L o o s e n   t w o   p r e a s s e m b l e d 

screws  across  from  each  other 

corresponding  to  the  open  slotted 

holes on the canopy upper rim and 

remove  the  other  two  screws  from 

mounting  bracket.  Keep  screws  for 

later use.

For  Canadian  installation  and  for  USA  fan  and  light 

kit  combinations  over  35  lbs,  in  both  flush  and 

downrod  mode  the  safety  cable  must  be  installed 

into  the  house  structure  beams  using  the  3”  lag 

screws,washers,  and  lock  washers.  provided.    Make 

sure that when the safety cable is fully extended the 

leadwires are longer than the cable and no stress is 

placed on the leadwires.

23

Lag screw

Washer

Lock washer

Safety cable

Lag screw

Safety cable

Safety cable installation

Flushmount Installation

27

Place  blade  bracket  onto  blade 

by aligning the 3 holes on blade 

as shown. 

28

Install  blade  bracket  with  blade  by 

3  blade  screws  provided.  Tighten 

securely.  Repeat  this  process  for 

remaining blades. 

29

Check  motor  for  shipping  stabilizers 

and remove if present. Install the blade 

assembly  to  motor  using  the  screws 

pre-installed.  Tighten  screws  securely. 

Repeat this process for remaining blade 

assemblies.

Hand free

hook

Shipping 

stabilizer

Supply

circuit

Отзывы: