Loosen the 2 set screws in yoke
for downrod to slip into yoke.
12
For Canadian installation and for USA fan and
light kit combinations over 35 lbs, in both flush
and downrod mode the safety cable must be
installed into the house structure beams using
the 3” lag screws,washers, and lock washers.
provided. Make sure that when the safety cable
is fully extended the leadwires are longer than
the cable and no stress is placed on the lead-
wires.
18
Safety cable installation
Safety Cable
Lag Screw
safety
cable
3” lag
screw
lock
washer
washer
Place the blade ring holder over
the leadwires and safety cable.
Place the blade ring holder onto
the blades aligning the screw
holes from the blades and ring
holder.
7
Install the motor screws by tighten-
ing securely.
8
Place the rubber gasket on the yoke
by threading the leadwires and safe-
ty cable through the rubber gasket
aligning the holes from the gasket
and yoke.
9
Re-place the upper motor housing
onto the fan motor. Be sure the
holes are all aligned.
10
Tighten the screws removed from
step 5. Tighten securely.
11
Place the canopy over the downrod
as shown above.
13
Thread the leadwires and safety
cable through the downrod.
14
Place the downrod into the yoke
aligning the keeper pin holes from
the yoke and downrod. Slide the
keeper pin through the holes and
install the cotter pin in the keeper
pin’s hole.
15
Tighten the set screws securely.
16
Hang the assembled fan from the
mounting bracket. Be sure to turn
the fan to lock the ridges from the
fan and mounting bracket in place.
17