Before you begin installing the fan, Switch
power off at Service panel and lock
service disconnecting means to prevent
power from being switched on
accidentally. When the service
disconnecting means cannot be locked,
securely fasten a warning device, such
as a tag, to the service panel.
Use AC 120V/60HZ power supply
only.
Before installing this fan makes sure the
outlet box is properly installed to the
house structure. Ensure the outlet box is
securely fastened by at least two points
to a structural ceiling member (a loose
box will cause the fan to wobble).
To reduce the risk of fire, electric shock,
or personal injury, mount to outlet box or
supporting system acceptable for fan
support.
(Mounting must support at least 35 lbs.)
Partially loosen 2 of the set screws on mount-
ing bracket corresponding to the slotted holes
on the canopy upper ring. Remove the other 2
set screws. Save screws.
Use metal outlet box suitable for fan
support and use only the screws provided
with the outlet box (must support 35 lbs).
Remove the two outlet box screws
provided with the box, aligning the holes
of the mounting bracket with the holes of
the outlet box. Reinstall the 2 outlet box
screws securely.
For Canadian installation and for USA fan
and light kit combinations over 35 lbs, in
both flush and downrod modes the safety
cable must be installed into the house
structure beams using 3” lag screws,
washers and lock washers provided.
Note
: If Installing The Secondary Support
Safety Cable in the U.S., Do Not Remove
Knockouts In The Outlet Box.
Place motor assembly on bottom
Styrofoam for blades installation.
Aligning the holes on blade, blade
supporting plate and the screw holes on
motor as shown in illustration, and then
partially install the set screws. Screws
provided. Repeat this process for
remaining blades.
Tighten all set screws securely after all
the blades are installed to motor.
Install decorative cap onto motor shaft by
turning clockwise until tight.
Flip the motor assembly with blades over.
Partially loosen downrod set screws from
yoke at top of motor assembly.
Remove preassembled cross pin and
keeper pin from downrod.
Ceiling
2˝ x 4˝
Ceiling
Joists
Outlet
Box
Safety cable
Junction
Box
Mounting
Bracket
Lag screw
Safety cable
Washer
Lock washer
Screw/ Washers
/Spring Washers
Ceiling joist
Outlet Box
Mounting
Bracket
SAFETY CABLE INSTALLATION
Blade
Blade supporting
plate
Decorative cap
Bottom Styrofoam
Cross
pin
Keeper
pin
Downrod
Yoke