Place yoke cover and canopy over lead 

wires, safety cable and downrod, and then 

replace the hanger ball.

Replace the hanger ball with pin 

and set screw. Tighten it securely.

 

Warning

: Make sure the 

pin

 is 

installed well on hanger ball with 

downrod. 

Install ball end of downrod into mounting 

bracket opening. Align (engage) slot on 

ball with tab on mounting bracket.

Warning:

 Failure to align slot on ball with 

tab may result in serious injury.

For Canadian installation and for USA fan 

and light kit combinations over 35 lbs, in 

both flush and downrod modes the safety 

cable must be installed into the house 

structure beams using 3” lag screws, 

washers and lock washers provided. 

Make sure that when the safety cable is 

fully extended the lead wires are longer 

than the cable and no stress is placed on 

the lead wires.

Note

: If Installing The Secondary Support 

Safety Cable in the U.S., Do Not Remove 
Knockouts In The Outlet Box.

  

SAFETY CABLE INSTALLATION

Lag screw

Safety cable

Washer

Lock washer

Tab

Slot

Make wiring connections as indicates 

above, using wire connectors provided.    

Connect Black wire from fan to Black 

(Live) wire from house. Connect White 

wire from Fan to White (Neutral) wire from 

house. Connect all green grounded wires 

to Grounded wire from House. Make sure 

that no filaments are outside of the wire 

connectors.

After making the wire connections, the wires 

should be spread apart with the grounded 

conductor and the equipment-grounding 

conductor on one side of the outlet box and 

ungrounded conductor on the other side of 

the outlet box. The splices after being made 

should be turned upward and pushed carefully 

up into the outlet box.              

Lift canopy and fix it on downrod with the 

preinstalled set screw, tighten the screw 

securely. The canopy should adjust for 

any irregularity in the ceiling or outlet 

box.

Power 

supply

Wall switch

Black

Black

White

White

Grounding/Green

Grounded

wires

Ungrounded

wires

Pin

Canopy

Yoke cover

Содержание 3AOR60 Series

Страница 1: ...sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 3AOR60XXX Series Fan cETL Model NO 3AOR60XXX 7 05 kg 15 51 lbs...

Страница 2: ...e building structure or the ceiling joist WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object...

Страница 3: ...a loose box will cause the fan to wobble Remove the two outlet box screws provided with the box aligning the holes of the mounting bracket with the holes of the outlet box Reinstall the 2 outlet box...

Страница 4: ...ondary Support Safety Cable in the U S Do Not Remove Knockouts In The Outlet Box SAFETY CABLE INSTALLATION Lag screw Safety cable Washer Lock washer Tab Slot Make wiring connections as indicates above...

Страница 5: ...pward Install the adapter onto fan housing with set screws provided Install the final cap and finial Install blade assembly Align the holes on blade bracket with the screw holes on the coupler of flyw...

Страница 6: ...Transmitter and receiver You must press the SET button with in 60 seconds of restoring power to the fan Note Fan will operate at minimum speed after the setting Note If the power is on already you mus...

Страница 7: ...If your fan is operated automatically after installation and power on it is because your fan is still memorize the previous setting at factory Make Remote control setting learn function and your fan w...

Страница 8: ...plate are tightened securely to 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a poin...

Страница 9: ...Jan 2020...

Отзывы: