bi-amped, active loudspeaker systems
2 A
8
2 A
4
-
2 A
2
-
W
iring of the power cable for the PowerCon
®
connector
(supplied with the unit).
Strip the cable for 20 mm of length and strip each wire for 8 mm of
length. We suggest to use a power cable with 1,5 ÷ 2 mm
2
section
wires (the insert terminals can however support a cable with wires up
to a section of 4 mm
2
/12AWG).
Insert the power cable into the bushing and into the chuck (white
chuck for a cable diameter of 5 ÷ 11 mm; black chuck for a cable
diameter of 9.50 ÷ 15 mm). Insert the wires into the terminals and
fasten the clamping device by a flat screw driver.
The wire ends can be clamped in or soldered to the terminal, always
paying attention to the symbols shown on the connector:
L (Live - corresponding to the brown wire),
N (Neutral - corresponding to the light blue wire) and
(Ground - corresponding to the yellow and green wire).
After connecting the wires to the insert, lead the cable through the
housing and screw down the bushing.
Important !
power
con
®
connector
housing
bushing
chuck
cable
setscrews
inside
view
insert
wires
cable
wires
20 mm
8 mm
14