***SPECIAL CAUTION***
DO NOT PLACE HIGH-HEAT PRODUCING EQUIPMENT ADAJACENT TO THE RIGHT SIDE
OF AN "SEK" VECTAIRE CONVECTION OVEN. EXCEEDING 185 DEGREES (F) (85 C)
SURFACE TEMPERATURES CAN CAUSE PREMATURE COMPONENT FAILURE NOT COVERED
UNDER THE MANUFACTURERS WARRANTY.
OPERATION
CONTROLS
STANDARD MODELS (SEK15A AND SEK2=15A-FIGURE 1)
1. "LIGHT-OFF" SWITCH CONTROLS THE OVEN INTERIOR LIGHTS.
2. "FAN-OFF" SWITCH CONTROLS THE FAN OPERATION. IT MUST BE ON FOR
POWER TO BE SUPPLIED TO THE ELEMENTS. WHEN THE DOORS ARE
OPENED, THE FAN WILL STOP.
3. THE "0-1" SWITCH TURNS ON POWER TO THE TEMPERATURE CONTROLLER
AND ENERGIZES THE DIGITAL DISPLAY.
4. THE CYCLE INDICATOR LIGHT BECOMES ILLUMINATED WHENEVER THE
CONTROL CALLS FOR MORE HEAT AND EXTINGUISHES WHEN THE CONTROL
IS SATISFIED.
5. THE TIME-SET KNOB IS USED TO SET THE AMOUNT OF COOKING TIME
DESIRED.
6. THE TEMPERATURE SET KNOB IS USED TO SET THE DESIRED COOK
TEMPERATURE.
*7. THE COOKING LOAD SWITCH REGULATES THE COOKING SENSETIVITY OF
THE OVEN. IN THE "NORMAL" POSITION THE HEATING ELEMENTS ARE AT
FULL CAPACITY, IN THE "LIGHT" SETTING THE HEATING ELEMENTS ARE
AT REDUCED CAPACITY. USE THE "LIGHT" SETTING FOR LESS DENSE
PRODUCTS, PARTIAL LOADS OR LONG LOW-TEMPERATURE COOK CYCLES.
8. KEY PAD CONTROLS . STANDARD MODELS CONTAIN ONLY TWO KEY-PADS. A
START-CANCEL-TIMER KEY IS USED FOR STARTING THE TIMER AND
CANCELLING THE BEEP ALARM, AND A TEMP-KEY WHICH WILL CAUSE
MEASURED OVEN TEMPERATURE TO APPEAR IN THE DISPLAY WINDOW WHEN
DEPRESSED.
* 480 VOLT UNITS HAVE NO "COOKING LOAD" SWITCH, AND OPERATE WITH
THE HEATING ELEMENTS AT FULL CAPACITY AT ALL TIMES.
PROGRAMMABLE MODELS (IE; SEK15AH AND SEK2-15AH--FIG. 2)
1. KEY-PAD-CONTROLS . PROGRAMMABLE MODELS CONTAIN NINE KEY-PADS.
THE START/TIMER AND TEMP KEYS ARE USED AS DESCRIBED WITH THE
STANDARD MODELS. THE SIX PROGRAM KEYS ARE NUMBERED AND ALLOW
THE USER TO PROGRAM AND STORE SIX INDIVIDUAL COOKING TIMES AND
TEMPERATURES. THE CANCEL KEY IS USED TO CLEAR A PRE-PROGRAMMED
COMMAND ONCE STARTED AND TO CANCEL THE END OF CYCLE BEEP
.