background image

MTLB-V1-051506

 

Page 

1 of 5

 

 

Copyright 2002-2006, Monster Tower, Inc

 

 

 

 

Monster Tower Light Bar 

Installation Instructions 

and Owners Manual

 

 

 

 

 

 

 

 

 

 

 
 
 

 

 

 

NOTES ON INSTALLING AND USING YOUR NEW TOWER LIGHTS 

 

 

Tower lights will reach a high temperature when operating.  Do not touch or wash the 

 

lights for 10 minutes after use. 

 Only use “H3 55W 12V” Halogen light bulb and fuse for replacement.  These are available 

 at most auto parts stores.  Anything exceeding 55W/15Amp could

 result in damage to

 

 your boat wiring. 

 

Use appropriate gauge wire for all connections. Consult wiring diagrams & wire sizing 
chart for details. 

 

Use of a relay is highly recommended unless you confirm your switch can support a 20 

amp load.  An inline fuse is required (see wiring diagram) 

 

Tower lights are not for wakeboarding at night, which is illegal in every state. 

 

There are countless methods of wiring lights.  Please contact a marine wiring specialist if 
you need assistance.  We have provided the most complete information we have found 
within this document.   

 

It is highly recommended that you use a relay and a fuse with each set of lights.

 

 

Содержание Light Bar

Страница 1: ...mp could result in damage to your boat wiring Use appropriate gauge wire for all connections Consult wiring diagrams wire sizing chart for details Use of a relay is highly recommended unless you confirm your switch can support a 20 amp load An inline fuse is required see wiring diagram Tower lights are not for wakeboarding at night which is illegal in every state There are countless methods of wir...

Страница 2: ...ollar Bracket 2 4 Delrin Collar Inserts 3 1 Tower Light Bar with Four Lights 4 4 M8x25 Socket Head Cap Screws Standard Two plus two light bar with two facing forward and two facing rear Light bar with four lights facing the same direction by turning around the end lights Lead wires with common ground Black and Red and Blue Power leads ...

Страница 3: ... provided for other towers Turning the lights to all face the same direction You can easily turn the outside lights so all four lights face in the same direction 1 Remove Light Bolts on each end of the light 2 Remove End Cap 3 Remove Bracket Bolts to remove the bracket 4 Remove threaded bar and insert into the opposite railing 5 Re assemble and align the center hole of the bracket where the wire e...

Страница 4: ...ocument for options details Running Wires Through The Tower The following is specific to running wires on a Monster Tower otherwise consult your tower installation manual or provider for instructions on running wire inside your tower When you add speakers or lights to your Monster Tower you can hide the wires inside of the rear legs of the tower as well as in the straight cross member of the top s...

Страница 5: ...MTLB V1 051506 Page 5 of 5 Copyright 2002 2006 Monster Tower Inc Wiring Option Diagrams and Wire Sizing Chart Follows ...

Страница 6: ...gative Ground Buss Bar See Note A Option 1 Single Switch w Relay NOTE In this configuration use 20 Amp Fuse for Relay 4 Amp Fuse for Switch NOTE See Wire Sizing Chart to determine proper gauge wire for each connection Each PAIR of lights draws 10 Amps 20 Amps total for single relay Each switch used in conjunction with a relay will draw less than 4 Amps Wire sizes apply to both Power Ground wires ...

Страница 7: ...ve Ground Buss Bar Switch Not Used See Note A Option 2 Dual Switches w Relays NOTE In this configuration use 10 Amp Fuse for Relays 4 Amp Fuse for Switches NOTE See Wire Sizing Chart to determine proper gauge wire for each connection Each PAIR of lights draws 10 Amps per relay Each switch used in conjunction with a relay will draw less than 4 Amps Wire sizes apply to both Power Ground wires ...

Страница 8: ... NOTE See Wire Sizing Chart to determine proper gauge wire for each connection Each PAIR of lights draws 10 Amps therefore each single switch used without a relay will draw up to 20 Amps Wire sizes apply to both Power Ground wires NOTE In this configuration use 20 Amp Fuse for Switch Option 3 Single Switch w o Relay ...

Страница 9: ...r 10 Amps NOTE In this configuration use 10 Amp Fuse for each Switch NOTE See Wire Sizing Chart to determine proper gauge wire for each connection Each PAIR of lights draws 10 Amps therefore each switch used without a relay will draw up to 10 Amps Wire sizes apply to both Power Ground wires Option 4 Dual Switches w o Relays ...

Страница 10: ......

Отзывы: