Installation and Wiring Instructions for the UMDTK Shower Extract Kit. 

 

IMPORTANT: READ THESE INSTRUCTIONS  

BEFORE COMMENCING THE INSTALLATION 

 
DO NOT install this product in areas where the following may 
be present or occur: 

  Excessive oil or a grease laden atmosphere. 

  Corrosive or flammable gases, liquids or vapours. 

• 

Ambient temperatures higher than 40°C or less than –5°C. 

• 

Possible obstructions which would hinder the access or 
removal of the Fan. 

  Sudden ductwork bends or transformations close to the Fan. 

 

SAFETY AND GUIDANCE NOTES 
A. 

All wiring to be in accordance with the current I.E.E.       
Regulations, or the appropriate standards of your country 
and 

MUST 

be installed by a suitably qualified person. 

B.

The Fan should be provided with a local double pole isolator 
switch having a contact separation of at least 3mm. 

C.

Ensure that the mains supply (Voltage, Frequency, and 
Phase) complies with the rating label. 

D.

The Fan should only be used in conjunction with the 
appropriate products. 

E. 

It is recommended that the connection to the fan connecter 
terminals is made with flexible cable. 

F. 

When the Fan is used to remove air from a room containing a 
fuel-burning appliance, precautions must be taken to avoid 
back-flow of gases into the room from the open flue of gas or 
other appliance.  Ensure that the air replacement is adequate 
for both the fan and the fuel-burning appliance. 

G. 

The Fan should not be used where it is liable to be subject to 

direct water spray for prolonged periods of time. 

H.

Where ducted Fans are used to handle moisture-laden air, a 
condensation trap should be fitted. Horizontal ducts should 
be arranged to slope slightly downwards away from the Fan. 