7 - Timer Models   

 

 
 
 
 
 
 
 

6 - Basic Models 

 

 

Timer adjuster 

 
 

 

 

B. 

WIRING.

 

 

WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM 
THE POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE. 

 

 

THE UMD FANS ARE DOUBLE INSULATED AND CARRY A        MARK. THERE ARE NO EARTH TERMINALS 
AND THESE FANS MUST NOT BE EARTHED. 

 

1.  Remove terminal box cover & screws and put to one side Fig. 5. 
2.  Select and follow the appropriate wiring diagram (Fig. 6-7). 
3.  Check all connections have been made correctly and ensure all terminal connections and cable clamps are 

securely fastened. 

4.  The cable entry must be made using the cable grommet provided. 
5.  Replace terminal box cover & screws Fig.9. 
6.  Ensure the impeller rotates and is free from obstructions. 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 
 
 
 
 
 
 
 
 
 
 
 

 

     

 
    

(Timer models cannot be used with a speed controller) 

 
 
 

 

 

 

Timer Adjustment. 
 

The fan must be wired to a remote switch (e.g. light switch). 
When switched ‘ON’, the fan will operate at the selected 
speed, and will continue to run for a pre-set time after the fan 
is switched ‘OFF’. The timer is factory set at 15 minutes 
approx. The overrun time period can be adjusted from 3-25 
minutes by altering the adjuster on the control PCB with the 
use of a small flat bladed screwdriver. Fig 9 

 

Before adjusting the timer, switch off the Mains Supply. 

 

Remove the fan terminal box cover and retain screws 
To INCREASE the operating time, turn the adjuster 

CLOCKWISE

To REDUCE the operating time, turn the adjuster

 ANTI-CLOCKWISE

.  

Replace the fan terminal box cover.

 

 
 

 

 