background image

PRODUCT OVERVIEW 

 

1.

 

Transport/MMC Buttons: Six MIDI Machine Control (MMC) buttons for controlling a 
sequencer. The buttons can be reassigned to transmit Control Change messages. 
The default functions, from top left to bottom right, are Loop, Rewind, Fast 
Forward, Record, Stop, and Play. 

2.

 

BANK Button: Press the BANK button to cycle through the four banks of settings. 
One of the LEDs to the right of the button illuminates to indicate the selected bank 
of settings. 

3.

 

BANK LEDs: Four LEDs, one of which illuminates to indicate the selected bank of 
settings. 

4.

 

Assignable Buttons: These two buttons can be configured to send Control Change 
messages. 

5.

 

Slider: This slider is a General Controller that cannot be reassigned. When connected 
to a hardware module, it serves as the Master Volume Controller. When connected 
to a DAW, it controls the volume of the SRP12 only. 

6.

 

Pads: Twelve velocity sensitive trigger pads that can be configured to send Note or 
Control Change messages. 

 

 

Содержание 625893

Страница 1: ...SRP12 USB Pad Controller P N 625893 User s Manual ...

Страница 2: ...ICE 4 PACKAGE CONTENTS 4 SYSTEM REQUIREMENTS 5 Windows 5 Mac OS X 5 PRODUCT OVERVIEW 6 DETAILED SETTINGS 7 Global 7 Trigger Pads 8 Assignable Buttons 9 Transport MMC Buttons 10 TECHNICAL SUPPORT 11 REGULATORY COMPLIANCE 11 Notice for FCC 11 Notice for Industry Canada 12 ...

Страница 3: ...llow it to fully dry before reapplying power Do not touch the device the power cord or any other connected cables with wet hands Do not expose this device to excessive vibration Do not subject the product to extreme force shock or fluctuations in temperature or humidity Do not expose this device to excessively high temperatures Do not place it in on or near a heat source such as a fireplace stove ...

Страница 4: ...er Service department is dedicated to ensuring that your ordering purchasing and delivery experience is second to none If you have any problem with your order please give us an opportunity to make it right You can contact a Monoprice Customer Service representative through the Live Chat link on our website www monoprice com or via email at support monoprice com Check the website for support times ...

Страница 5: ...es Note that USB hubs are not supported Windows Pentium 800 MHz or higher CPU requirement may be higher for laptops 256MB RAM DirectX 9 0b or later Windows XP SP2 or later Mac OS X Mac G3 800 MHz or G4 733 MHz or higher G3 G4 accelerator cards not supported OS X 10 3 9 with 256MB RAM or OS X 10 4 2 or later with 512MB RAM ...

Страница 6: ...he right of the button illuminates to indicate the selected bank of settings 3 BANK LEDs Four LEDs one of which illuminates to indicate the selected bank of settings 4 Assignable Buttons These two buttons can be configured to send Control Change messages 5 Slider This slider is a General Controller that cannot be reassigned When connected to a hardware module it serves as the Master Volume Control...

Страница 7: ...sages that are sent when a button is pressed This should be set to match the MIDI channel of the application that you are controlling The range of values is 1 16 Transport MIDI Channel This specifies the MIDI channel that the controller will use to send MIDI messages when the MMC buttons are pressed This should be set to the MIDI channel of the application that you are controlling The possible val...

Страница 8: ...ted on the Global MIDI channel The possible values are 1 16 and Global MIDI Channel Assign Type This specifies the type of message that will be assigned to the Trigger Pad You can disable the pad No Assign or assign a Note message or a Control Change message The possible values are No Assign Note or Control Change Pad Behavior You can choose one of two types of behavior for each Trigger Pad Moment...

Страница 9: ...hange Button Behavior You can choose one of two types of behavior for the Button Momentary or Toggle If set to Momentary the Note On or On Value will be transmitted when you press the Button and the Note Off or Off Value will be transmitted when it is released If set to Toggle the Note On or On Value will be transmitted the first time you press the Button and the Note Off or Off Value will be tran...

Страница 10: ...ll be transmitted when you press the Button and a Control Change message with a value of 0 will be transmitted when it is released If set to Toggle a Control Change message with a value of 127 will be transmitted the first time you press the Button and a Control Change message with a value of 0 will be transmitted the next time it is pressed This can only be changed if the Assign Type is set to MM...

Страница 11: ...ed operation Modifying the equipment without Monoprice s authorization may result in the equipment no longer complying with FCC requirements for Class B digital devices In that event your right to use the equipment may be limited by FCC regulations and you may be required to correct any interference to radio or television communications at your own expense This equipment has been tested and found ...

Страница 12: ...ry Canada This Class B digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe B est conforme à la norme NMB 003 du Canada Monoprice Stage Right the Stage Right logo and all Monoprice logos are trademarks of Monoprice Inc Apple Mac and OS X are trademarks of Apple Inc registered in the U S and other countries Microsoft Windows Vista and DirectX are either registered t...