background image

Important! The installation operations must be carried out by suitably trained personnel taking into account the 
information given by this manual. 

 
TECHNICAL INFORMATION:  
 

POWER 

LITHIUM BATTERY AA 4x1,5V 

MIN/MAX PRESSURE OF USE 

0,5÷8 bar (recommended 3 bar) 

MAXIMUM TEMPERATURE OF USE  

60°C 

SENSOR DISTANCE  

10 cm ± 2 cm 

WATER FLOW 

6 L/min con 3 bar of pressure  

FLEXIBLE CONNEXION 

G 1/2" Female 

FLEXIBLE LENGTH  

40 cm 

NON RETURN VALVE  

Included  

LOW BATTERY SIGNAL 

yes 

ANTI VANDALIC SYSTEM   

yes 

 

MAIN DATA SYSTEM 

 

Field sesitivity  

100mm ± 20mm (Non-adjustable)

 

Auto-closing valve 

 

The ignition, avoiding water escaping.

 

Maximum opening delay

 

400msec (depending on the pressure)

 

Closure delay (Comfort time)

 

Standard: ~6 sec ± 1 sec 

Auto-closure for blinding sensor (Antivaldalic)

 

Standard: ~1min 

Anti-legionella distribution

 

Automatic Operation after 24 hours of Unuse

 

Tensione delle batterie sotto 5,2Vdc

 

The system not allows the valve’s opening 

 

RED Led for low battery status signal. For each action on user request, if the battery is no longer able to activate the valve, the LED flashes.

 

LED  on fixed at  start  to  show  the  correct  connection.  At  each opening  and closing  control  valve  a  short  flashing  of  the  LED.  In  case  of 
almost discharged batteries, indication with 3 flashes. In case of exhausted batteries indication with 6 flashes.

 

Reverse polarity Protection.

 

Algorithmic Correction of sensor response to the sudden variation of ambient temperature.

 

The sensor is equipped with a system of minimization of electromagnetic disturbances. 

4,5

50

18

51

64

84

~3

20

O

 40,5

 

WARNINGS: 
 

-For use with water only 
-Only for indoor use 
-Do not use toxic or abrasive products to clean the faucet 

 
MAINTENANCE:  

 

Important! Any maintenance operation must be carried out by suitably trained personnel taking into account the 
information given by this manual. 

Periodically Wipe the sensor with a mild damp cloth. 
Periodically Clean the filter of the shut-off tap in the supply line. 

 
DISPOSAL OF POLLUTING MATERIAL: 

 

In  case  of  maintenance  or  demolition  of  the  product,  the  parts  of  which  it  is  composed  must  be  entrusted  to 
companies specialized in the disposal and recycling of industrial waste, in transposition of the European Directive 
2012/19/EU (WEEE) concerning the disposal Electrical and electronic equipment and, in particular: 
-DISPOSAL OF THE PACKAGING: 
The packaging consists of biodegradable cardboard that can be delivered to companies for the normal recovery of 
cellulose. 
-DISPOSAL OF METAL PARTS: 
The metallic parts are recoverable from the companies specialized in the metal scrapping sector. 
 
 

 

MAIN DATA BATTERY HOLDER 

 

 
 

Supported batteries

 

4 lithium primary batteries type AA 1,5V

 

Protection class

 

IPX5 

 

 

Содержание ZEUS001/PM

Страница 1: ...FAUCETS FOR LARGE INSTALLATIONS USER AND MAINTENANCE MANUAL ZEUS001 PM ELECTRONIC SINK TAP PREMIUM LINE POWERED BY BATTERY 4x1 5V AA WITH MECHANICAL PRE MIXER ...

Страница 2: ...e operations Use only LITHIUM batteries for greater durability and efficiency of the product INSTALLATION INSTRUCTIONS Always bleed the piping before installation and at every temporary closure of the system 1 Close the water supply 2 Pierce the sink ø33 3 Manually Tighten the tie rod 2 to the base of the already assembled tap 1 Insert The sealing base 3 and O Ring 4 into the already assembled tap...

Страница 3: ...cation with 3 flashes In case of exhausted batteries indication with 6 flashes Reverse polarity Protection Algorithmic Correction of sensor response to the sudden variation of ambient temperature The sensor is equipped with a system of minimization of electromagnetic disturbances 4 5 50 18 51 64 84 320 O 40 5 WARNINGS For use with water only Only for indoor use Do not use toxic or abrasive product...

Страница 4: ...lines all responsibility for any damage that may directly or indirectly result in persons and or things as a result of failure to comply with all the prescriptions indicated in the following Instruction Manual and concerning Especially the warnings regarding installation use and maintenance FAILURE TO COMPLY WITH THE INSTRUCTIONS CONTAINED IN THIS BOOKLET IMPLIES THE FORFEITURE OF THE GUARANTEE CE...

Отзывы: