Monogram ZWL1126SJ Скачать руководство пользователя страница 3

3

Installation Instructions

CLEARANCES AND DIMENSIONS

•  

Dimensions that are shown in Figure 1 (for 

24”) must be used. Given dimensions provide 

minimum clearance. Locate electrical outlet in 

the shaded area in the upper left-hand corner 

of the cutout. See Figure 4.

•  

Contact surface must be solid and level. Pay 

special attention to the floor on which the 

Drawer Microwave will sit. The floor of the 

opening should be constructed of plywood 

strong enough to support the weight of the 

oven (about 100 pounds).

•  

Check location where the Drawer Microwave 

will be installed for proper electrical supply.

•  

Your oven can be built into a cabinet or wall 

by itself or under a gas, under an electric wall 

oven, or under selected cook top models.  See 

use and care manual for list of models.

•  

Be sure that the clearance of the floor between 

the wall oven and the drawer microwave is a 

minimum of 2-inches.

•  

The microwave interior will easily accommodate 

a 9” x 13” oblong dish or a bag of microwave 

popcorn.

•  

The oven can also be mounted flush. Please 

see instructions for flush mounting included 

with the Flush Mount Deflector vent.

24” DRAWER MICROWAVE 

MEASUREMENTS

Figures 1 and 2 contain many drawer microwave 

measurements for reference when planning the 

drawer location.
This drawer microwave can be installed below 

any electric or gas wall oven or under selected 

cook top models.  See use and care manual for 

list of models.
Can also be installed using an electrical outlet in 

an adjacent cabinet within the areas where the 

provided electrical cord can reach. Power cord 

access hole in cabinet should be a minimum of 

1 1/2” diameter hole and deburred of all sharp 

edges.

Always allow sufficient power cord length to the 

electrical outlet to prevent tension.
Always check electrical codes for requirements.

24” DRAWER MICROWAVE 

MEASUREMENTS (Continues)

.

 

 

 

 

   

 

 

 

 

Anti-Tip

Block

1

/

2

14 

13

/

16

to bottom

of Anti-Tip

Block

Floor must 

support 

100 lbs.

Figure 1

Figure 2

IMPORTANT

(6”)

5”

4”

Allow 1 

1

/

16

” 

overlap

14 

13

/

16

”  

opening

Allow 

1

/

16

” 

overlap

18 

1

/

2

” to top  

of floor

24”  

cabinet min.

36”  

countertop 

height

Allow  

7

/

8

” 

overlap

23 

1

/

2

”  

min depth

Allow  

7

/

8

” 

overlap

22 

1

/

8

”  

opening

Suggested electrical 

outlet location*

11

/

16

3

/

4

4”

21 

5

/

8

15 

15

/

16

14 

19

/

32

15”  

auto drawer 

opening

21 

7

/

8

1

/

4

”  

door thick-

ness

23 

7

/

8

1” = 2.5 cm; 1’ = 0.3 m

Содержание ZWL1126SJ

Страница 1: ...49 40754 2 01 18 GEA Installation Instructions Monogram Drawer Microwave For Models ZWL1126SJ...

Страница 2: ...Microwave must be secured by a properly installed Anti Tip block This Drawer Microwave must be electrically grounded in accordance with local codes Make sure the wall coverings and the cabinets aroun...

Страница 3: ...r flush mounting included with the Flush Mount Deflector vent 24 DRAWER MICROWAVE MEASUREMENTS Figures 1 and 2 contain many drawer microwave measurements for reference when planning the drawer locatio...

Страница 4: ...ed using an electrical outlet in an adjacent cabinet within the area where the provided electrical cord can reach Always check electrical codes for requirements T GROUNDING INSTRUCTIONS This appliance...

Страница 5: ...his installation with the consumer PARTS INCLUDED Qty Description 1 Flush Mount Deflector Vent 2 Mounting Screws 1 Prepare cabinet opening as shown in Figures 6 7 8 and 9 Figure 6 Suggested Electrical...

Страница 6: ...the face of the cabinet pushing the face of the drawer out 1 8 Mounting Cleat Drawer Face 1 8 1 3 16 Cabinet Face Suggested Electrical Outlet Location Anti Tip Block 24 3 16 min 24 1 2 max 22 No Oven...

Страница 7: ...t Plug the power supply cord into the electrical outlet 4 Carefully guide the drawer into the prepared opening Avoid contact with the sides of the cutout opening and also pinching the cord between the...

Страница 8: ...8 Notes TINSLB048MRR0l...

Страница 9: ...49 40754 2 01 18 GEA Instructions d installation Four micro ondes tiroir Monogram Pour les mod les ZWL1126SJ...

Страница 10: ...tre fix correctement au moyen d un bloc antibasculement Ce four micro ondes tiroir doit tre mis la terre conform ment aux codes en vigueur dans votre r gion Assurez vous que les rev tements muraux et...

Страница 11: ...euses mesures pour le four micro ondes tiroir qui peuvent vous servir de r f rence lors de la planification de l emplacement du four Ce micro ondes tiroir peut tre install en dessous de tout four enca...

Страница 12: ...cien qualifi ou un technicien du service apr s vente Il peut galement tre install dans une armoire adjacente dans les zones o le cordon lectrique fourni avec l appareil peut atteindre une prise lectri...

Страница 13: ...on 1 D flecteur de ventilation encastr 2 Vis de montage 1 Pr parez l ouverture de l armoire comme illustr dans les figures 6 7 8 et 9 Figure 6 Emplacement sugg r de la prise lectrique 5 po 6 po Bloc a...

Страница 14: ...oir de 1 8 po Cale de fixation Face avant du tiroir 1 8 po 13 16 po Face avant de l armoire Emplacement sugg r de la prise lectrique Bloc anti basculement 243 16 po min 241 2 po max 22 po Sans four La...

Страница 15: ...stall 3 Placez le four tiroir proximit de l ouverture du mur ou de l armoire Branchez le cordon d alimentation dans la prise lectrique 4 Guidez soigneusement le four tiroir dans l ouverture vitez de t...

Страница 16: ...8 Notes TINSLB048MRR0l...

Отзывы: