background image

Design Guide - Flush Installation

These units are equipped with a 3-position door stop. 
The factory set 115° door swing can be adjusted to 90° if 
clearance to adjacent cabinets or walls is restricted. 

When Installed into a corner:

Allow 15” for a full 115° door swing and pan removal. 
Allow 4” min. clearance when door swing is adjusted 
to a 90° opening for pan access, but pan removal is 
restricted.

Clearances for Multiple Single Door Installations 

 

In a side-by-side installation of a left and right door swing 
product, a 1” clearance between the units is required. 
Order ZUG2 Unified Grille Panel Kit for one continuous 
grille panel.

CLEARANCES

ZUG2 Unified Grille Panel Kit

• If you are installing two units, side by side, the installation 

space must be 75” wide.

Note: 

Additional cutout width may be required when side panels 

are used. Add side panel thickness to the finished cutout to 
calculate rough-in width.

 •  The water and electrical locations for each product must be 

located as shown.

•  A separate 115V, 60Hz., 15 or 20 amp power supply is 

recommended for each product.

Note:

 When implementing a dual installation, the factory 

installed standard case trim should be used on the handle side 
of each unit and the supplied flush case trim should be used on 
the hinge side of each unit.

75" Finished Width

4-5/16"

24-3/16"

9"

7"

7-1/2" 7-1/2"

7"

5-1/2"

9"

5-1/2"

Electrical

Electrical

Area

Cold Water

Suppl

y

Wall View

Cold Water

Suppl

y

26-3/16" Minimum

Cutout Depth

85"

Finished
Opening

3-1/2"

3-1/2"

3-1/2"

3-1/2"

3-1/2"

3-1/2" 3-1/2"

3-1/2"

3-1/2"

3-1/2"

15"

Min. to

Wall

15"

Min. to

Wall

115° Door

Swing

1"

115° Door

Swing

38-3/4"

4" Min. to Wall

90° Door Swing

INSTALLATION

24

CUSTOM HANDLE DESIGN GUIDE

Custom handles must be used for flush installation. For 
custom handle installation, counterbore holes in rear of 
decorative panels must ensure 1/2” material thickness 
remains for handle support.

  

NOTE: 

The counterbore must not exceed 1” in 

diameter.

Minimum distance from handle 
side edge to handle center should 
be 3-1/2” as shown.

1/4”

1/2”

3/4”

7/8"

0.85"

1/2"

3-1/2”

Содержание ZIRP360NHLH

Страница 1: ...Installation Instructions 36 Built In All Refrigerators and All Freezers monogram com...

Страница 2: ...ck Hazard Plug into a grounded 3 prong outlet Do not remove the ground prong Do not use an adapter Immediately replace electric cords that become frayed or damaged Do not use an extension cord with th...

Страница 3: ...es pi ces la port e des enfants g s de moins de 3 ans ATTENTION Risque associ la manutention d une charge lourde Ce r frig rateur est tr s lourd Pour r duire le risque de blessure lors de la manutenti...

Страница 4: ...nel Routing 27 3 4 Raised Grille Panel Routing 28 3 4 Raised Door Panel Routing for Unified Installation 29 Side Panels 30 Side Cleats 30 ZUG2 Grille Panel Dimensions 30 Unified Door Panel Dimensions...

Страница 5: ...Instructions for Standard Installation 5...

Страница 6: ...hould be 1 4 O D copper tubing or QuickConnect kit between the cold water line and water connection location long enough to extend to the front of the unit Installation of an easily accessible shut of...

Страница 7: ...r supply is recommended for each product Clearances for Multiple Single Door Installations In a side by side installation of a left and right door swing product a 1 clearance between the units is requ...

Страница 8: ...panels ZUG2 For side by side installation of two trimmed models This kit provides for the installation of a unified custom grille panel to span the width of two units using a framed or overlay panel...

Страница 9: ...thick must be placed between the overlay and backer panel IMPORTANT NOTE Maximum total weight for assembled door panel is 67 pounds Maximum total weight for assembled grille panel is 11 pounds Assembl...

Страница 10: ...rim ZUG2 GRILLE PANEL DIMENSIONS The ZUG2 unified grille panel kit provides for the installation of a framed or overlay grille panel Depending on installation height Assemble the overlay panels in the...

Страница 11: ...ew 130 DOOR SWING Scale 1 1 Frameless Cabinets The case trim overlaps cabinets at the top and sides Therefore frameless cabinets may require filler strips to prevent interference with cabinet door swi...

Страница 12: ...which mates with a standard 3 prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance Have the wall outlet and circuit checked by a qualified electric...

Страница 13: ...or rupture with age and cause water damage to your home SmartConnect Refrigerator Tubing Kits are available in the following lengths 2 6 m WX08X10002 8 2 4 m WX08X10006 15 4 6 m WX08X10015 25 7 6 m WX...

Страница 14: ...nd must be secured to prevent the possibility of tipping forward AVERTISSEMENT Risque de basculement L appareil m nager est beaucoup plus lourd en haut et il faut le maintenir en place pour viter la p...

Страница 15: ...etal studs for stability Install the wall tog gles as follows Drill 1 2 holes at the wall markings made in the holes at the ends of the wall bracket Hold the metal channel flat against the plastic str...

Страница 16: ...e the power cord inside the left cavity If it has not been adjusted so the plug is easily accessible do so now Move Unit into Final Position Move appliance toward its final installed location Align th...

Страница 17: ...ay for a snug fit against the unit add the washers one at a time until the pin will fit tightly into the hole Align the straight section of the pin with the hole from the underside of the rod Push the...

Страница 18: ...factory installed in the 115 position Close the door Use pliers to unscrew the door stop and reinstall in the 90 degree or 130 degree position Pin Location for 90 Door Swing Pin Location for 130 Door...

Страница 19: ...Secure Handle Use Front Holes to Secure Trim Right hand models shown Use the same instruc tions for left hand models IF YOU ARE INSTALLING OVERLAY PANELS GO TO STEP 10A Install Door Panel Open the do...

Страница 20: ...et manufacturer will supply the custom han dle and hardware Secure the door trim using new handle side trim Discard the supplied handle Right hand models shown Use the same instruc tions for left hand...

Страница 21: ...ghten one additional turn with a wrench Overtightening can cause leaks Turn on the water to check for leaks NOTE Make sure excess tubing length does not interfere with the toekick installation Freezer...

Страница 22: ...Instructions for Flush Installation 22...

Страница 23: ...back wall The water line should be 1 4 O D copper tubing or QuickConnect kit between the cold water line and water connection location long enough to extend to the front of the unit Installation of a...

Страница 24: ...r and electrical locations for each product must be located as shown A separate 115V 60Hz 15 or 20 amp power supply is recommended for each product Note When implementing a dual installation the facto...

Страница 25: ...cker panel to the overlay panel Secure the overlay panel to the backer panel with glue and screws Screws must be countersunk into the backer panel Fresh Food Door Grille 1 4 Backer Panel 69 5 16 x 33...

Страница 26: ...d by cabinet maker to avoid sharp edges on the panels Edges to be treated should include the top bottom and hinge side edges IMPORTANT NOTE Maximum total weight for the assembled panels Door panel 67...

Страница 27: ...ched door trim 1 4 11 32 1 4 3 4 PANEL SIDE VIEW AFTER ROUTING Front TOP DETAIL TOP CORNER VIEW SHOWING PICTURE FRAME ROUTING DETAIL BOTTOM BOTTOM Back Front Back 7 16 3 4 1 4 NOTE Routed areas should...

Страница 28: ...ched grille trim 3 4 PANEL SIDE VIEW AFTER ROUTING 3 4 PANEL BOTTOM VIEW AFTER ROUTING Front TOP DETAIL TOP CORNER VIEW SHOWING PICTURE FRAME ROUTING DETAIL BOTTOM BOTTOM LEFT SIDE RIGHT SIDE DETAIL L...

Страница 29: ...ROUTING 3 4 PANEL BOTTOM VIEW AFTER ROUTING Front TOP DETAIL TOP CORNER VIEW SHOWING PICTURE FRAME ROUTING DETAIL BOTTOM BOTTOM HINGE SIDE HANDLE SIDE DETAIL HINGE SIDE DETAIL HANDLE SIDE Back Front B...

Страница 30: ...erlay Panel Dimensions A Width B Height 1 4 Backer Panel 69 7 8 8 7 8 0 10 Spacer Panel 68 1 2 7 5 8 1 2 Smooth Panel 74 10 7 16 IMPORTANT NOTE The maximum weight for the unified grill is 25 pounds De...

Страница 31: ...unding plug which mates with a standard 3 prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance Have the wall outlet and circuit checked by a qualifi...

Страница 32: ...s approved plastic tubing is supplied in the SmartConnect Refrigerator Tubing kits Do not use any other plastic water supply line because the line is under pressure at all times Other types of plastic...

Страница 33: ...ints on the horizontal line Place the bottom of the wall bracket with tabs on the horizontal line Align the center notch on the bracket with the center line on the wall The anti tip wall bracket has a...

Страница 34: ...Tighten with a wrench Insert the bolts into the toggle by hand until snug Tighten with a wrench Install Wall Toggles The wall toggles and bolts can be ordered as Service Kit WR49X10193 Wall toggles ar...

Страница 35: ...ed above the front wheels Turn clockwise to raise or counterclockwise to lower the unit For front leveling use a 1 1 4 open end wrench Adjust height of unit to match installation cutout opening 84 1 2...

Страница 36: ...36 Pin Location for 90 Door Swing Pin Location as Shipped for 115 Door Swing STEP 8 INSTALL GRILLE PANEL Raise the access panel to the stop position Loosen the screws on the side trim behind the fram...

Страница 37: ...our refrigerator in place of the trim piece you just removed Place trim against the side of the refrigerator door aligned top to bottom The holes in the trim should align to the holes in the door Disc...

Страница 38: ...nection Tighten the compression nut until it is just hand tight Tighten one additional turn with a wrench Overtightening can cause leaks Turn on the water to check for leaks NOTE Make sure excess tubi...

Страница 39: ...Instructions for Stainless Steel Installation 39...

Страница 40: ...oor or back wall The water line should be 1 4 O D copper tubing or QuickConnect kit between the cold water line and water connection location long enough to extend to the front of the unit Installatio...

Страница 41: ...power supply is recommended for each product Clearances for Multiple Single Door Installations In a side by side installation of a left and right door swing product a 1 clearance between the units is...

Страница 42: ...pliances These models are shipped ready for installation Optional Accessory Kits ZUGSS2 For side by side installation of two stainless steel wrapped models This kit provides a unified stainless steel...

Страница 43: ...p View 130 DOOR SWING Scale 1 1 Frameless Cabinets The case trim overlaps cabinets at the top and sides Therefore frameless cabinets may require filler strips to prevent interference with cabinet door...

Страница 44: ...h a standard 3 prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance Have the wall outlet and circuit checked by a qualified electrician to make sure...

Страница 45: ...iances approved plastic tubing is supplied in the SmartConnect Refrigerator Tubing kits Do not use any other plastic water supply line because the line is under pressure at all times Other types of pl...

Страница 46: ...on Instructions Stainless Steel Installation 46 Mark an additional hole at each end of the bracket If one of the studs is closer to the end of the bracket mark an additional hole towards the center of...

Страница 47: ...and into the stud Tighten with a wrench Insert the bolts into the toggle by hand until snug Tighten with a wrench Anti Tip Wall Bracket Bolt Wall Toggle Drywall or Steel Stud Installation Instructions...

Страница 48: ...wrench Adjust height of unit to match installation cutout opening 84 1 2 The unit should be level and plumb with cabinetry CAUTION The rear leveling wheels and front leveling legs are limited to a ma...

Страница 49: ...ll fit tightly into the hole Align the straight section of the pin with the hole from the underside of the rod Push the pin up until it snaps into position Pliers may be used NOTE The hair pin cotter...

Страница 50: ...er connection Tighten the compression nut until it is just hand tight Tighten one additional turn with a wrench Overtightening can cause leaks Turn on the water to check for leaks NOTE Make sure exces...

Страница 51: ...51 Notes...

Страница 52: ...afety glasses or goggles should be worn For Monogram local service in your area call 1 800 432 2737 NOTE Product improvement is a continuing endeavor at General Electric Therefore materials appearance...