background image

Installation Instructions - Stainless Steel Installation

44

HARDWARE SUPPLIED

• Water filter bypass plug
• Anti-Tip brackets
• 3 lag screws
• 2 Hair Pin Cotters
• 4 washers
• 5 toggles with bolts
• Toekick

TOOLS AND MATERIALS 
REQUIRED

• Tin snips to cut banding

• #2 Phillips screwdriver

• Stepladder 

• Drill and 1/2”, 3/16” bits

• Bucket

• 1/4”, 1/2”, 5/16”, 7/16” socket 

• Level

• Safety glasses

• Appliance hand truck

• Pliers

• Tubing cutter

• Stud finder

•  7/16” and 1-1/4” open-end wrench

• 1/4” copper water line tubing or SmartConnect

 

Refrigerator Tubing kits

• Water shut-off valve (optional but recommended)

• Screws to secure unit to cabinetry

• Stick-on hook and loop fastener strips for 1/4” side 

panels

FLOORING

For proper installation, this product must be placed  
on a level surface of hard material that is at the same 
height as the rest of the flooring. This surface should 
be strong enough to support a fully loaded refrigerator 
or freezer, or approximately 1,200 lbs. per unit.

NOTE: 

Protect the finish of the flooring. Cut a large 

section of the cardboard carton and place under the 
product where you are working.

NOTE: 

Not recommended for installation on carpeted 

flooring.

GROUNDING THE UNIT

WARNING

  Electrical Shock Hazard.  

Failure to follow these instructions can result in death, 
fire, or electrical shock.

The power cord of this appliance is equipped with a 
3-prong (grounding) plug which mates with a standard 
3-prong (grounding) wall receptacle to minimize the 
possibility of electric shock hazard from this appliance.

Have the wall outlet and circuit checked by a qualified 
electrician to make sure the outlet is properly grounded.

Where a standard 2-prong wall outlet is encountered, it 
is your personal responsibility and obligation to have it 
replaced with a properly grounded 3-prong wall outlet.

DO NOT, UNDER ANY 
CIRCUMSTANCES, CUT OR 
REMOVE THE THIRD (GROUND) 
PRONG FROM THE POWER CORD.

DO NOT USE AN ADAPTER 
PLUG TO CONNECT THE 
REFRIGERATOR TO A 2-PRONG OUTLET.

DO NOT USE AN EXTENSION CORD WITH THIS 
APPLIANCE.

LA TERRE DE L’UNITÉ 

AVERTISSEMENT

  Risque de choc 

électrique.

Le non-respect de ces instructions peut entraîner des 
risques d’incendies, des chocs électriques ou la mort.

Le cordon d’alimentation de cet appareil est équipé 
d’une fiche à trois broches (pour une mise à la terre) 
qui s’adapte à la prise de courant standard à 3 broches 
(pour une mise à la terre) pour minimiser les risques de 
chocs électriques par cet appareil.

Faites vérifier la prise murale et le circuit électrique par 
un électricien qualifié pour s’assurer que le système est 
correctement mis à la terre.

Dans le cas d’une prise biphasée, l’installateur a la 
responsabilité et l’obligation de la remplacer par une 
prise triphasée correctement mise à la terre.

NE COUPEZ PAS OU N’ENLEVEZ PAS, SOUS 
AUCUN PRÉTEXTE, LA TROISIÈME 
BROCHE DE MISE À LA TERRE DU 
CORDON D’ALIMENTATION.

N’UTILISEZ PAS D’ADAPTATEUR 
POUR BRANCHER LE 
RÉFRIGÉRATEUR À UNE PRISE BIPHASÉE.

N’UTILISEZ PAS DE RALLONGE AVEC CET 
APPAREIL.

Содержание ZIFS360NHH

Страница 1: ...36 Built In All Refrigerators and All Freezers Design Guide With Installation Instructions Installation Instructions monogram com...

Страница 2: ...l Shock Hazard Plug into a grounded 3 prong outlet Do not remove the ground prong Do not use an adapter Immediately replace electric cords that become frayed or damaged Do not use an extension cord wi...

Страница 3: ...etites pi ces la port e des enfants g s de moins de 3 ans ATTENTION Risque associ la manutention d une charge lourde Ce r frig rateur est tr s lourd Pour r duire le risque de blessure lors de la manut...

Страница 4: ...r Panel Routing 27 3 4 Raised Grille Panel Routing 28 3 4 Raised Door Panel Routing for Unified Installation 29 Side Panels 30 Side Cleats 30 ZUG2 Grille Panel Dimensions 30 Unified Door Panel Dimensi...

Страница 5: ...Instructions for Standard Installation 5...

Страница 6: ...ne should be 1 4 O D copper tubing or QuickConnect kit between the cold water line and water connection location long enough to extend to the front of the unit Installation of an easily accessible shu...

Страница 7: ...power supply is recommended for each product Clearances for Multiple Single Door Installations In a side by side installation of a left and right door swing product a 1 clearance between the units is...

Страница 8: ...erlay panels ZUG2 For side by side installation of two trimmed models This kit provides for the installation of a unified custom grille panel to span the width of two units using a framed or overlay p...

Страница 9: ...0 10 thick must be placed between the overlay and backer panel IMPORTANT NOTE Maximum total weight for assembled door panel is 67 pounds Maximum total weight for assembled grille panel is 11 pounds As...

Страница 10: ...de trim ZUG2 GRILLE PANEL DIMENSIONS The ZUG2 unified grille panel kit provides for the installation of a framed or overlay grille panel Depending on installation height Assemble the overlay panels in...

Страница 11: ...op View 130 DOOR SWING Scale 1 1 Frameless Cabinets The case trim overlaps cabinets at the top and sides Therefore frameless cabinets may require filler strips to prevent interference with cabinet doo...

Страница 12: ...plug which mates with a standard 3 prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance Have the wall outlet and circuit checked by a qualified ele...

Страница 13: ...ack or rupture with age and cause water damage to your home SmartConnect Refrigerator Tubing Kits are available in the following lengths 2 6 m WX08X10002 8 2 4 m WX08X10006 15 4 6 m WX08X10015 25 7 6...

Страница 14: ...vy and must be secured to prevent the possibility of tipping forward AVERTISSEMENT Risque de basculement L appareil m nager est beaucoup plus lourd en haut et il faut le maintenir en place pour viter...

Страница 15: ...nd metal studs for stability Install the wall tog gles as follows Drill 1 2 holes at the wall markings made in the holes at the ends of the wall bracket Hold the metal channel flat against the plastic...

Страница 16: ...ocate the power cord inside the left cavity If it has not been adjusted so the plug is easily accessible do so now Move Unit into Final Position Move appliance toward its final installed location Alig...

Страница 17: ...r away for a snug fit against the unit add the washers one at a time until the pin will fit tightly into the hole Align the straight section of the pin with the hole from the underside of the rod Push...

Страница 18: ...is factory installed in the 115 position Close the door Use pliers to unscrew the door stop and reinstall in the 90 degree or 130 degree position Pin Location for 90 Door Swing Pin Location for 130 D...

Страница 19: ...Secure Handle Use Front Holes to Secure Trim Right hand models shown Use the same instruc tions for left hand models IF YOU ARE INSTALLING OVERLAY PANELS GO TO STEP 10A Install Door Panel Open the do...

Страница 20: ...et manufacturer will supply the custom han dle and hardware Secure the door trim using new handle side trim Discard the supplied handle Right hand models shown Use the same instruc tions for left hand...

Страница 21: ...and tight Tighten one additional turn with a wrench Overtightening can cause leaks Turn on the water to check for leaks NOTE Make sure excess tubing length does not interfere with the toekick installa...

Страница 22: ...Instructions for Flush Installation 22...

Страница 23: ...back wall The water line should be 1 4 O D copper tubing or QuickConnect kit between the cold water line and water connection location long enough to extend to the front of the unit Installation of a...

Страница 24: ...r and electrical locations for each product must be located as shown A separate 115V 60Hz 15 or 20 amp power supply is recommended for each product Note When implementing a dual installation the facto...

Страница 25: ...cker panel to the overlay panel Secure the overlay panel to the backer panel with glue and screws Screws must be countersunk into the backer panel Fresh Food Door Grille 1 4 Backer Panel 69 5 16 x 33...

Страница 26: ...d by cabinet maker to avoid sharp edges on the panels Edges to be treated should include the top bottom and hinge side edges IMPORTANT NOTE Maximum total weight for the assembled panels Door panel 67...

Страница 27: ...ched door trim 1 4 11 32 1 4 3 4 PANEL SIDE VIEW AFTER ROUTING Front TOP DETAIL TOP CORNER VIEW SHOWING PICTURE FRAME ROUTING DETAIL BOTTOM BOTTOM Back Front Back 7 16 3 4 1 4 NOTE Routed areas should...

Страница 28: ...ched grille trim 3 4 PANEL SIDE VIEW AFTER ROUTING 3 4 PANEL BOTTOM VIEW AFTER ROUTING Front TOP DETAIL TOP CORNER VIEW SHOWING PICTURE FRAME ROUTING DETAIL BOTTOM BOTTOM LEFT SIDE RIGHT SIDE DETAIL L...

Страница 29: ...ROUTING 3 4 PANEL BOTTOM VIEW AFTER ROUTING Front TOP DETAIL TOP CORNER VIEW SHOWING PICTURE FRAME ROUTING DETAIL BOTTOM BOTTOM HINGE SIDE HANDLE SIDE DETAIL HINGE SIDE DETAIL HANDLE SIDE Back Front B...

Страница 30: ...erlay Panel Dimensions A Width B Height 1 4 Backer Panel 69 7 8 8 7 8 0 10 Spacer Panel 68 1 2 7 5 8 1 2 Smooth Panel 74 10 7 16 IMPORTANT NOTE The maximum weight for the unified grill is 25 pounds De...

Страница 31: ...unding plug which mates with a standard 3 prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance Have the wall outlet and circuit checked by a qualifi...

Страница 32: ...s approved plastic tubing is supplied in the SmartConnect Refrigerator Tubing kits Do not use any other plastic water supply line because the line is under pressure at all times Other types of plastic...

Страница 33: ...ints on the horizontal line Place the bottom of the wall bracket with tabs on the horizontal line Align the center notch on the bracket with the center line on the wall The anti tip wall bracket has a...

Страница 34: ...Tighten with a wrench Insert the bolts into the toggle by hand until snug Tighten with a wrench Install Wall Toggles The wall toggles and bolts can be ordered as Service Kit WR49X10193 Wall toggles ar...

Страница 35: ...ed above the front wheels Turn clockwise to raise or counterclockwise to lower the unit For front leveling use a 1 1 4 open end wrench Adjust height of unit to match installation cutout opening 84 1 2...

Страница 36: ...36 Pin Location for 90 Door Swing Pin Location as Shipped for 115 Door Swing STEP 8 INSTALL GRILLE PANEL Raise the access panel to the stop position Loosen the screws on the side trim behind the fram...

Страница 37: ...our refrigerator in place of the trim piece you just removed Place trim against the side of the refrigerator door aligned top to bottom The holes in the trim should align to the holes in the door Disc...

Страница 38: ...freezer connection Tighten the compression nut until it is just hand tight Tighten one additional turn with a wrench Overtightening can cause leaks Turn on the water to check for leaks NOTE Make sure...

Страница 39: ...Instructions for Stainless Steel Installation 39...

Страница 40: ...ater line should be 1 4 O D copper tubing or QuickConnect kit between the cold water line and water connection location long enough to extend to the front of the unit Installation of an easily accessi...

Страница 41: ...power supply is recommended for each product Clearances for Multiple Single Door Installations In a side by side installation of a left and right door swing product a 1 clearance between the units is...

Страница 42: ...pliances These models are shipped ready for installation Optional Accessory Kits ZUGSS2 For side by side installation of two stainless steel wrapped models This kit provides a unified stainless steel...

Страница 43: ...p View 130 DOOR SWING Scale 1 1 Frameless Cabinets The case trim overlaps cabinets at the top and sides Therefore frameless cabinets may require filler strips to prevent interference with cabinet door...

Страница 44: ...h a standard 3 prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance Have the wall outlet and circuit checked by a qualified electrician to make sure...

Страница 45: ...iances approved plastic tubing is supplied in the SmartConnect Refrigerator Tubing kits Do not use any other plastic water supply line because the line is under pressure at all times Other types of pl...

Страница 46: ...on Instructions Stainless Steel Installation 46 Mark an additional hole at each end of the bracket If one of the studs is closer to the end of the bracket mark an additional hole towards the center of...

Страница 47: ...and into the stud Tighten with a wrench Insert the bolts into the toggle by hand until snug Tighten with a wrench Anti Tip Wall Bracket Bolt Wall Toggle Drywall or Steel Stud Installation Instructions...

Страница 48: ...wrench Adjust height of unit to match installation cutout opening 84 1 2 The unit should be level and plumb with cabinetry CAUTION The rear leveling wheels and front leveling legs are limited to a ma...

Страница 49: ...ll fit tightly into the hole Align the straight section of the pin with the hole from the underside of the rod Push the pin up until it snaps into position Pliers may be used NOTE The hair pin cotter...

Страница 50: ...nce or freezer connection Tighten the compression nut until it is just hand tight Tighten one additional turn with a wrench Overtightening can cause leaks Turn on the water to check for leaks NOTE Mak...

Страница 51: ...51 Notes...

Страница 52: ...book safety glasses or goggles should be worn For Monogram local service in your area call 1 800 432 2737 NOTE Product improvement is a continuing endeavor at General Electric Therefore materials app...

Отзывы: