– 28 –
Regulator
Solid Piping
or Flexible
Connector
Shut-Off
Valve
Pipe Stub
To Cooktop
GAS SUPPLY
1
Measure the incoming gas pressure to the regulator.
With the installation of this conversion kit, the cooktop
should operate on LP gas at 10” of water column pressure
and on natural gas at 5” of water column pressure.
• The pressure regulator must be connected in series
with the manifold of the cooktop and must remain in
series with the supply line.
• When checking the regulator, the inlet pressure must be
at least 1” greater than the regulator output setting.
– If the regulator is set for 10” of water column
pressure, the inlet pressure must be at least 11”.
– If the regulator is set for 5” of water column pressure,
the inlet pressure must be at least 6”.
For proper operation, the maximum inlet pressure to the
regulator must be no more than 14” of water column pressure.
Connection: 1/2” N.P.T.—minimum 5/8” dia. metal flex line.
IMPORTANT:
Disconnect the cooktop and the
individual shut-off valve from the gas supply piping system
during any pressure testing of that system at test pressures
greater than 1/2 psig. Isolate the cooktop from the gas supply
piping system by closing the individual manual shutoff valve
to the cooktop during any pressure testing of the gas supply
piping system at test pressures equal to or less than 1/2 psig.
To Cooktop
Regulator
Pipe Stub
Shut-Off
Valve
Solid Piping
or Flexible
Connector
Remove the burner caps and main burner head (brass).
NOTE: Do not remove the burner base.
• Remove the orifice using a 7 mm nut driver.
There are 2 orifices on each burner.
• Use a piece of sticky tape in the socket to prevent
the loose orifice from falling out.
• Verify that the orifices in the kit match the chart
sizes below and replace the orifices. See chart below
for correct orifice sizes.
REPLACE ALL BURNER ORIFICES
2
A. TO REMOVE THE BURNER PARTS:
B. TO REPLACE BURNER ORIFICES:
• Align the hole in the burner head with the electrode on
the burner base. Seat in place.
• Replace the burner caps.
C. TO REPLACE BURNER PARTS:
ORIFICE SIZES (see orifice locations in Section 4)
Burner Cap
Burner Head
Burner Base
Electrode
Main
Orifice
Simmer
Orifice
NATURAL—Above 5,000 Feet:
(MM) NATURAL—5,000 FEET
BTU RATES
MAIN
1.26
1.38
1.78
1.78
SIM
0.43
0.43
0.47
0.47
HI
10K
12K
18K
18K
LO
2400
2400
2400
2400
SIM
1100
1100
1200
1200
BURNER
Rear
Front
Large Ctr.
Large Front
LP—Above 5,000 Feet:
(MM) LP—5,000 FEET
BTU RATES
MAIN
0.77
0.77
0.99
0.99
SIM
0.31*
0.31*
0.31
0.31
HI
9.1K
9.1K
15K
15K
LO
2400
2400
2400
2400
SIM
1100
1100
1200
1200
BURNER
Rear
Front
Large Ctr.
Large Front
* No orifice change required.
High Altitude Conversion