Monogram Monogram ZISB360DR Скачать руководство пользователя страница 29

29

Manufactured for: General Electric Company, Louisville, KY 40225
EPA EST. No. 070595-MN-001

Performance Data Sheet

SmartWater Filtration System

MWF Cartridge

This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration 
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.*

(100% safety factors built in for unmetered usage)

Standard No. 42: Aesthetic Effects

USEPA

Influent

Influent

Effluent

% Reduction

Min. Required

Parameter

MCL

Challenge Concentration

Average

Average

Maximum

Average

Minimum

Reduction

Chlorine

2.0 mg/L + 10%

1.96 mg/L

0.06 mg/L

0.11 mg/L

96.77%

94.74%

> 50%

T & O

Particulate**

≥ 10,000 particles/mL

6,400,000 #/mL

58,833 #/mL

150,000 #/mL

99.14%

97.97%

≥ 85%

Standard No. 53: Health Effects

USEPA

Influent

Influent

Effluent

% Reduction

Min. Required

Parameter

MCL

Challenge Concentration

Average

Average

Maximum

Average

Minimum

Reduction

Turbidity

0.5 NTU

11 + 1 NTU***

10.5 NTU

0.14 NTU

0.28 NTU

98.54%

97.20%

0.5 NTU

Cysts

≥ 99.95% Reduction

Minimum 50,000 L

118,750 #/L

< 1 #/L

4 #/L

> 99.99%

> 99.99%

≥ 99.95%

Asbestos

≥ 99% Reduction

10

7

to 10

8

fibers/L; > 10μm

57 MF/L

0.996 MF/L

< 1 MF/L

99.60%

99.39%

≥ 99%

Lead at pH 6.5

0.015 mg/L

0.15 mg/L + 10%

0.1567 mg/L

< 0.001 mg/L

< 0.001 mg/L

99.36%

99.29%

0.010 mg/L

Lead at pH 8.5

0.015 mg/L

0.15 mg/L + 10%

0.1433 mg/L

< 0.001 mg/L

< 0.001 mg/L

99.30%

99.29%

0.010 mg/L

Mercury at pH 6.5

0.002 mg/L

0.006 mg/L + 10%

0.0059 mg/L

0.000350 mg/L

0.0007 mg/L

94.70%

87.50%

0.002 mg/L

Mercury at pH 8.5

0.002 mg/L

0.006 mg/L + 10%

0.0057 mg/L

0.000325 mg/L

0.0006 mg/L

93.20%

89.29%

0.002 mg/L

Alachlor

0.002 mg/L

0.04 mg/L + 10%

0.0367 mg/L

0.00023 mg/L

0.0004 mg/L

99.34%

98.67%

0.002 mg/L

Lindane

0.0002 mg/L

0.002 mg/L + 10%

0.0020 mg/L

< 0.00002 mg/L < 0.00002 mg/L

99.00%

98.95%

0.0002 mg/L

2,4-D

0.070 mg/L

0.210 mg/L + 10%

0.2033 mg/L

0.00337 mg/L

0.011000 mg/L

98.32%

94.50%

0.070 mg/L

Toxaphene

0.003 mg/L

0.015 mg/L + 10%

0.0160 mg/L

0.00100 mg/L

0.001000 mg/L

93.44%

91.67%

0.003 mg/L

Benzene

0.005 mg/L

0.015 mg/L + 10%

0.0145 mg/L

0.000500 mg/L 0.000500 mg/L

96.51%

95.83%

0.005 mg/L

Carbofuran

0.040 mg/L

0.080 mg/L + 10%

0.0830 mg/L

0.001000 mg/L 0.001000 mg/L

98.78%

98.65%

0.04 mg/L

1,4 dichlorobenzene

0.075 mg/L

0.225 mg/L + 10%

0.2283 mg/L

0.000500 mg/L 0.000500 mg/L

99.78%

99.77%

0.075 mg/L

Atrazine

0.003 mg/L

0.009 mg/L + 10%

0.0087 mg/L

< 0.0005 mg/L

< 0.0005 mg/L

94.22%

93.33%

0.003 mg/L

* Tested using a flow rate of 0.50 gpm; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 3°C)
** Measurement in Particles/ml. Particles used were 0.5-1 microns
*** NTU=Nephelometric Turbidity units

Operating Specifications

Capacity: certified for up to 300 gallons (1135 l); up to six months for models without a replacement filter indicator light; 
up to one year for models with a replacement filter indicator light

Pressure requirement: 40–120 psi (2.8–8.2 bar), non-shock

Temperature: 33–100ºF (0.6–38ºC)

Flow rate: 0.5 gpm (1.9 lpm)

General Installation/Operation/Maintenance Requirements

Flush new cartridge at full flow for 3 minutes to purge out trapped air.

Replace cartridge when the indicator light flashes or water flow rate is reduced on non-indicator units.

Special Notices

Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.

This drinking water system must be maintained according to manufacturer’s instructions, including replacement of filter cartridges.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or 
after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.

The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.

Check for compliance with the state and local laws and regulations.

Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Systems must be
installed and operated in accordance with manufacturer’s recommended procedures and guidelines.

NSF

®

System Tested and Certified by NSF International against ANSI/NSF Standard 42 & 53 for the reduction of:

Standard No. 42: Aesthetic Effects

Chemical Unit

Chlorine Taste and Odor

Mechanical Filtration Unit

Particulate Reduction, Class I

Standard No. 53: Health Effects

Chemical Reduction Unit

Alachlor and Atrazine Reduction
Benzene and Carbofuran Reduction
1,4 dichlorobenzene and 2,4-D Reduction
Lead and Lindane Reduction
Mercury and Toxaphene Reduction

Mechanical Filtration Unit

Turbidity Reduction
Cyst and Asbestos Reduction

Содержание Monogram ZISB360DR

Страница 1: ...Owner s Manual Side by Side 36 42 48 Built In Refrigerators 49 60467 1 12 08 JR monogram com...

Страница 2: ...to be a built in product custom panels are required on the front of the Monogram refrigerator Consult your kitchen designer or cabinetmaker for your customized look The information on the following pa...

Страница 3: ...t the people who serviced your appliance Explain why you are not pleased In most cases this will solve the problem NEXT if you are still not pleased write all the details including your phone number t...

Страница 4: ...could damage the refrigerator and seriously injure themselves After your refrigerator is in operation do not touch the cold surfaces in the freezer compartment particularly when hands are damp or wet...

Страница 5: ...frig rateur et se blesser gravement Une fois le r frig rateur en marche ne touchez pas les surfaces froides du cong lateur surtout si vous avez les mains humides ou mouill es la peau risque d adh rer...

Страница 6: ...nded 3 prong wall outlet Use of a GFI Ground Fault Interruptor is not recommended for the refrigerator outlet The appliance should always be plugged into its own individual electrical outlet which has...

Страница 7: ...t Interruptor n st pas recommand pour la prise de courant du r frig rateur La machine gla ons doit toujours tre branch dans sa propre prise de courant dont la tension nominale est identique celle indi...

Страница 8: ...7 F will appear in the display To check the current temperature setting for the fresh food or freezer compartment press the or pad once After 5 seconds the display will return to the actual temperatur...

Страница 9: ...TEN To Reset the Filter Status Light Press and hold the RESET pad for 3 seconds Filter Bypass Plug You must use the filter bypass plug a if you have a household reverse osmosis water system and or ano...

Страница 10: ...en the refrigerator is first installed there may be air in the water line system Press the dispenser cradle for at least two minutes to remove trapped air from the water line and to fill the water sys...

Страница 11: ...quick chilled in the ice storage bin Cans bottles or food packages in the storage bin may cause the icemaker or auger to jam To keep dispensed ice from missing the glass put the glass close to but no...

Страница 12: ...en light will come on Throw away the first full bucket of ice Be sure nothing interferes with the sweep of the feeler arm When the bin fills to the level of the feeler arm the icemaker will stop produ...

Страница 13: ...is complete the pan will automatically adjust to a temperature of 27 37 F to store the food at its optimum temperature Climate Control Tray Besides using the specially designed Climate Control tray w...

Страница 14: ...20 oz Bottles of Beverage 4 to 6 Small Juice Boxes 6 8 oz each 3 Foil Juice Packets 45 Minutes 2 Liter of Beverage 1 2 Gallon of Juice Gelatin 1 package 0 5 Lbs 4 hours Individually Wrapped Filet Mign...

Страница 15: ...vel NOTE The Climate Control drawer can be used as another sealed produce pan by turning the controls on the Climate Control drawer off The temperature inside the drawer will be the same as the fresh...

Страница 16: ...ift the back of the pan up and out To replace a pan 1 Place the back of the pan in the wire holder making sure the wire holder fits into the grooves on the back of the pan 2 Lower the front of the pan...

Страница 17: ...height With shelf front raised slightly engage top lugs in tracks at rear of cabinet Then lower front of shelf until it locks into position Shelves and Bins Built In Refrigerators Door bins All door...

Страница 18: ...the top grille panel and set the Sabbath Mode switch to the ON position A green LED light will be visible below the Sabbath Mode Kit switch The light will be visible when the grille is closed between...

Страница 19: ...r such as Stainless Steel Magic to preserve and protect the fine finish Stainless Steel Magic and the Monogram polishing cloth are available through GE Parts and Accessories 800 626 2002 or monogram c...

Страница 20: ...ition OFF arr t The refrigerator uses two types of halogen bulbs Type 1 The columns along the back wall of the fresh food and freezer compartments are lit up by lamps located behind the top pan in the...

Страница 21: ...compartment remove the bottom freezer basket See Freezer Baskets section 3 On the back wall there is a curved light shield Grasp each end of the light shield Pull the shield toward you and the tabs o...

Страница 22: ...E Always follow bulb manufacturer s directions for handling and replacing bulbs 7 Remove the bulb by holding the base and pulling straight out Replace with a new bulb and replace the lamp protector WA...

Страница 23: ...until the arrow points toward the back of the refrigerator then lift up 4 Turn the lamp protector to access the bulb NOTE Always follow bulb manufacturer s directions for handling and replacing bulbs...

Страница 24: ...eaker Clean the interior see Cleaning Inside Leave doors open For shorter vacations remove perishable foods and leave controls at regular settings However if the room temperature is expected to drop b...

Страница 25: ...t most of the time you will hear low or no SOUNDS operating noise Normal fan air flow one fan blows cold air through the fresh food and freezer compartments another fan cools the compressor motor The...

Страница 26: ...ge may be holding door open FROST OR ICE Door left open or package holding door open CRYSTALS ON Too frequent or too long door openings FROZEN FOOD Frost within package is normal SLOW ICE CUBE Door ma...

Страница 27: ...eck for a connection to a Reverse Osmosis water system If an RO is connected remove the water filter and install the original bypass plug that came with the unit WATER ON If you use an extra tall glas...

Страница 28: ...URTING Newly installed filter cartridge Run water from the dispenser for FROM DISPENSER 3 minutes about one and a half gallons NO WATER OR ICE Water supply line turned off restricted or not connected...

Страница 29: ...8 78 98 65 0 04 mg L 1 4dichlorobenzene 0 075 mg L 0 225 mg L 10 0 2283 mg L 0 000500 mg L 0 000500 mg L 99 78 99 77 0 075 mg L Atrazine 0 003 mg L 0 009 mg L 10 0 0087 mg L 0 0005 mg L 0 0005 mg L 94...

Страница 30: ...y Code for the following health related contaminants Cysts Turbidity Asbestos Lead Mercury Alachlor Atrazine Benzene Carbofuran Lindane Mercury Toxaphene 1 4 dichlorobenzene 2 4 D Microbiological Cont...

Страница 31: ...ntracts In the USA 800 626 2224 In Canada 1 800 561 3344 You can have the secure feeling that GE Consumer Service will still be there after your warranty expires Purchase a GE contract while your warr...

Страница 32: ...l costs to your home All warranty service will be provided by our Factory Service Centers or by our authorized Customer Care servicers during normal working hours Should your appliance need service du...

Отзывы: