Robin L sealer RevA19 17-01-19
5.0 INSTALLATION
•
The sealer will be supplied completely assembled and ready for use, including a fitted
power supply plug.
•
The sealer's electrical supply must be 230/250V a.c., Single Phase, 50Hz, capable of
carrying 13 amps.
•
If a sensitive magnetic trip is used in the supply line, this must be rated at 20 amps. to
allow for the peak impulse current.
•
The sealer must be installed on a level surface.
•
Check the sealing arm is level and adjust if necessary.
•
Ventilation should be adequote to allow the small amount of fumes to be removed from
the working area.
•
The sealer should be installed away from areas where the atmospheric conditions are
such as to present a fire or explosion hazard. (dust ,flour etc.)
The supply to this machine must be protected by a
30mA RCD