background image

Eco 1-60 Package – Page 3
Issued – March 2013
Reference – MPA552/5

Eco 1-60 Package

Protecting your Grinder Pump Unit

The grinder pump will handle any waste water (sewage) 
that is normally discharged from your toilets, bathroom, 
laundry or kitchen.

Do not put any of the following into toilets, sinks or drains 

as it may damage or affect the operation of the package.

•  Glass,  metal,  wood,  seafood  shells  or  other  hard 

objects.

•  Cloth or synthetic material.
•  Any chemical other than standard cleansing or laundry 

products including toxic, caustic, acidic or poisonous 
substances.

•  Degreasing solvents.
•  Explosive or flammable material including hydrocarbon 

fuels, paint thinner or anti-freeze.

•  Oils and grease.
•  Hair clippings.
•  Sanitary towels or condoms.

While the grinder/pump may handle some of these items, 
it is desirable to keep them out of the sewerage system.

What to do if high level alarm is on

Do not panic.

This alarm indicates that sewage has reached the high 
level point, but in the standard tank there is still 600 litres 
of emergency storage remaining.

Take the following steps.

•  In the controller, set the audible alarm to mute to stop 

the siren.

•  Discontinue water usage in your premises unless in an 

emergency.

•  Wait 15 minutes to ascertain if the pump reduces the 

level in the tank.

•  If warning light goes out - the situation has corrected 

and water usage can proceed as normal.

•  If warning light remains on – contact technician. See 

contact details on back page.  Do not open the tank lid 

or turn off the power.

In case of power outage (blackout)

Discontinue  water  usage,  except  in  an  emergency 

situation, until power is restored.

Emptying a pool or spa

 

(Greater than normal bath size)

If you have added a pool or spa to your system after 
installation of the Eco 1-60 PSS unit, you need to ensure 

that they are not emptied at a greater flow rate than the 
pump can handle.  This is ensured by either putting flow 

restrictions in the pool/spa discharge line to control the 

flow  rate  or  fitting  a  extra  storage  tank  before  the  PSS 

unit.  Please discuss this with your plumber or technician 
as per the contact details on back page.

If premises is being left unoccupied for a lengthy 
period

If the premises is being left unoccupied for a lengthy 

period, for example going on holidays for 5 days or more 

run a tap within your premises, stopping after the grinder 
pump turns on.  The Grifter unit will then pump down to 
the low level ensuring the tank holds a minimum quantity 
of clean water and cleansing the pump of sewage. 

 

This ensures that sewage is not left in the tank to emit 
stagnating odours.

Shut off the water supply at the mains to avoid leaking 

taps overflowing the tank in your absence.

Turn the controller power off with the isolator on the side.

Do not forget to turn the controller on after your return and 

before any water usage.

If these guidelines are followed your Mono Grifter Package 
will provide you with many years of unobtrusive, “hassle 
free” operation.

For further details please refer to the “Installation, 
Operation and Maintenance Instructions” supplied with 
this unit.

If you have further concerns or queries please do not 
attempt to service the unit, contact the technician/help 
desk as per the contact details on back page.