background image

WARRANT Y

SPECIFICATIONS

B U L L E T I N

434

Monitor Technologies LLC

44W320 Keslinger Rd.  

t  

Elburn, IL 60119  

t

630-365-9403   

t

800-766-6486  

t

Fax: 630-365-5646   

t

www.monitortech.com

SAFET Y

        General Safety  

CAUTION:  It is essential that all instructions in this manual be followed to

ensure proper operation of the equipment and safety of operating person-

nel.  Use of equipment not specified herein, may impair protection provid-

ed by equipment.  The use of this symbol is used throughout manual to

highlight important safety issues.  Please pay particular attention to these

items.

        Electrical Shock Caution

Certain MK-2 models are powered with HIGH VOLTAGE.  No operator

serviceable parts are inside.  All servicing is to be performed by qualified

personnel.  Each MK-2 is provided with a "protective conductor terminal"

which  shall  be  terminated  to  earth  ground  potential  (See  Electrical

Installation).  This product's design complies with EN61010-1 installation

category II and pollution degree 2.

        hazardous Location Caution

Certain  MK-2  models  can  be  used  in  Hazardous  Locations  (See

Specifications).  These models shall only be used in applications covered

by stated ratings or those considered non-hazardous.  Failure to comply

could result in damage to personnel and property.  The following must be

maintained to assume safe operation:

1)

  Enclosure integrity - The dimensions of the housing, cover or probe 

     shall not be altered.

2)

  Electrical integrity - Substitution of electrical components may impair 

     intrinsic safety and therefore is prohibited.

3)

  Maintenance - Power to all circuits must be disconnected before con-

     ducting any investigation or maintenance.

Electromagnetic Compatibility (EMC)

The MK-2 was tested and found to comply with the standards listed below.

The MK-2 should not be used in residential or commercial environments.

Compliance  to  EMC  standards  was  demonstrated  by  means  of  a  test

setup using the following installation methods.

1)  

MK-2 enclosure was connected to earth ground (protective earth).

2)

  No specific wiring convention was used to supply power or 

to retrieve output signal from the MK-2.

EMC Emissions:

Meets   EN 61326-1      Electrical Equipment for Control Use, EMC 

             EN 55011         Radiated and conducted emissions 

                                      (Class A- industrial)

             EN 61000-3      Fluctuations/Flicker

Meets   FCC Part 15B:     RF Devices, Unintentional Radiators

             CISPR 11             Radiated and conducted emissions 

                                          (Class A- industrial)

EMC Immunity:

Meets   EN 61326-1           Electrical Equipment for Control Use, 

                                           EMC 

             IEC 1000-4-2         Electrostatic discharge (industrial)

             IEC 1000-4-3         RF radiated EM fields (industrial)

             IEC 1000-4-4         Electrical fast transients (industrial)

             IEC 1000-4-5         Electrical surges (industrial)

             IEC 1000-4-6         RF conducted EM energy (industrial)

             IEC 1000-4-8         Power frequency magnetic fields 

                                           (industrial)

             IEC 1000-4-11       Source voltage deviation

Ryton

®

- Trademark of Phillips Chemical Co.    Teflon

®

- Trademark of DuPont Chemical Co.

Power:

                             48-240 VAC ±10%, 50/60Hz; 24-48VDC ±10%, 3W

Altitude:

                           6562 ft (2000 m) max

Installation Category:

    II

Pollution Degree:

           4 (reduced to 2 by enclosure) Suitable for indoor/outdoor use

Ambient Op Temp:

         -40˚ F (-40˚ C) to +150˚ F (+65˚ C)

*

Internal bin Temp:

        To +176˚ F (+80˚ C) w/alum. mount (<104˚ F (40˚ C) ambient)

                                          To +400˚ F (+204˚ C) w/SS mount (<122˚ F (50˚ C) ambient)

Output Relay:

                  DPDT, 5A @ 250VAC, 30VDC maximum

Indicators:

                       “DET” yellow LED illuminates when material is sensed

                                          “OPR” red LED illuminates to  indicate output switching

                                          “CAL” green LED illuminates to indicate proper calibration

                                          “SEN” bank of four LEDs indicate the sensitivity setting

External Indicators:

        Red and green LEDs indicating power and operating mode

                                          (Ordinary location units only)

Sensitivity

:                       Switch selectable 0.5pf, 2.6pf, 8.3pf, 18.0pf

Stability

:                           ±0.01pf per degree F (±0.018pf per degree C) @ 0.5pf setting

Time Delay

:                     0.25 to 15 sec single-turn adj. for delay to activate & delay to de-activate

Fail-Safe:

                        Switch selectable - HI/LO

build-up Immunity:

        Protected via driven shield to 150 ohm load

Enclosure:

                       Cast alum screw-on cover, polyester pwdr coat, 

                                          NEMA 4 / ENCLOSURE TYPE 4

Conduit Connection:

      Two (2) 3/4” NPT connections (M20 cable glands provided when 

                                          1-1/2” BSPT process connection is specified)

**Approvals:

                    CSA

US

CSA

C

Ordinary Locations, CE Mark(Ordinary location only)

                                          CSA

US

CSA

C

: Class I Groups C,D, Exp. Proof & Intrinsically Safe 

                                          CSA

US

CSA

C

: Class II Groups E, F & G, 

Dust Ignition Proof & Intrinsically Safe

                                   CHINA RoHS 2

Standard/Food Grade Probe

    Mounting:                   1-1/4” NPT alum, R 1-1/2 (BSPT 1-1/2), or combo 3/4” NPT 316SS and 

                                      1-1/4” NPT alum

    Probe Material:          3/8in(9.5mm) dia. 316SS probe & guard, Ryton

®

or equiv. & Nylon insulators

    Probe Length:            16in(406mm) from alum mounting

    Temp (Probe Only):   Ryton

® 

or equiv.: +450˚ F (+232˚ C) max; Nylon: +300˚ F (+148˚ C) max

    Pressure:                   50 psi(3.5 bar) max (alum connection);150 psi(10 bar) max (3/4” NPT SS)

Stub Probe

    Mounting:                   1-1/4” NPT alum, R 1-1/2 (BSPT 1-1/2), or combo 3/4” NPT 316SS and 

                                      1-1/4” NPT alum

    Probe Material:          3/8in(9.5mm) dia. 316SS probe & guard, Ryton

®

or equiv. & Nylon insulators

    Probe Length:            9in (229mm) from aluminum mounting

    Temp (Probe Only):   Ryton

®

or equiv.: +450˚ F (+232˚ C) max; Nylon: +300˚ F (+148˚ C) max

    Pressure:                   50 psi(3.5 bar) max (aluminum); 150 psi(10 bar) max (3/4 NPT SS)

Cable Extension Probe

    Mounting:                   1-1/4” NPT alum, R 1-1/2 (BSPT 1-1/2), or combo 3/4” NPT 316SS and 

                                      1-1/4” NPT alum

    Probe Material:          1/8in(3.2mm) diameter 316 SS Teflon

®

jkt’d cable, Nylon insulator

    Cable Length;            Customer specified from 17” (432 mm) up to 50 ft (15 m)

                                      overall insertion from alum mtg

    Temp (Probe Only):   +300˚ F (+148˚ C) max

    Pressure:                   50 psi(3.5 bar) max (1-1/4 NPT alum); 150 psi(10 bar) max (3/4 NPT SS)

Pipe Extension Probe

    Mounting:                   1-1/4” NPT alum 

    Lag Material:              Galvanized or 316SS 

    Pipe Ext Length:        Customer specified from 22” (559 mm) up to 144in (3.6m) overall insertion

    Interface To:              Standard or Food Grade (See applicable specs)

Lagged housing Version

    Mounting:                   3/4” NPT 316SS 

    Lag Material:              Galvanized or 316SS 

    Lag Length:               Customer specified from 7 to 24 in (178 to 610 mm)

    Interface To:              Standard Probe only (See applicable specs)

Split Architecture

    Elec. Enclosure:        Cast Aluminum, screw-on cover, polyester powder coat (HL)

                                      Fiberglass enclosure (OL)

    Cable:                        12 ft (3.6m), 22 awg co-ax / 18 awg wire

    Max Bin Temp:          Ryton

®

or equiv. probe: 450˚ F (+232˚ C); Nylon: 300˚ F (+148˚ C)

*Influenced by mounting, material thermal conductivity and ambient temperature.

**Hazardous location approvals on units with Pipe Extension or Lagged Probes with integral elec-

  tronics/probe are CSA

US/C

Class II Groups E, F & G (SS version ONLY.  Hazardous location 

  approvals are not available on the galvanized version).  Hazardous location approvals for Split 

  Architecture remote electronics are Class II, Groups E, F & G.  All probe versions, except the gal-

  vanized version of the pipe extension or lagged probe unit, are Class I Groups C &D, Class II 

  Groups E, F & G and Intrinsically Safe.

         

Monitor Technologies LLC warrants each 

True

Cap

®

RF capacitance sensor it manufactures

to be free from defects in material and workmanship under normal use and service for two

(2) years from the date of purchase.  The purchaser must notify Monitor of any defects within

the warranty period, return the product intact, and prepay transportation charges.  The oblig-

ation of Monitor Technologies LLC under this warranty is limited to repair or replacement at

its factory.  This warranty does not apply to any product which is repaired or altered outside

of Monitor Technologies’  factory, or which has been subject to misuse, negligence, accident,

incorrect wiring by others, or improper installation. 

JCS

JSC

OCT 26 2018

DOC-001-434A     16

Содержание TrueCap MK-2

Страница 1: ...o will ensure proper operation of the equipment and the safety of all personnel Before discarding shipping container please inspect it thoroughly and verify that all parts ordered are accounted for So...

Страница 2: ...low into and out of the ves sel Insure that the expected swing of the cable will not touch the vessel 3 Driven Shield Penetration Select a location which ensures that the driven shield section protrud...

Страница 3: ...ion in accordance with the Pre Installation Recommendations 2 If using a welded coupling cut a hole into the side top of the vessel corresponding to the mounting connection i e 1 1 2 BSPT 1 1 4 NPT or...

Страница 4: ...ion and the mains outputs Remove electronics 4 backpanel screws prior to drilling holes 3 The Remote Electronics for Hazardous Locations has three conduit entrances one of which is plugged at the fact...

Страница 5: ...DV B0051 3 50 x 3 00 A 09 13 16 ISOLATED LINES LOAD L L LOAD LINES ISOLATED L L DCV L1 N ACV RECOMMENDED NOT CRITICAL NO2 NC2 COM2 WIRING DIAGRAM ADV B0051 3 50 x 3 00 A 09 13 16 ISOLATED LINES LOAD L...

Страница 6: ...ON LEDS RED PUSHBUTTON CALIBRATION LED YELLOW DETECTION LED GREEN CALIBRATION LEDS RED SE PUSHBUTTON CALIBRATION LED YELLOW DETECTION LED GREEN CALIBRATION LEDS RED S PUSHBUTTON CALIBRATION LED YELLOW...

Страница 7: ...ion 2 Set the time delay desired from 25 to 15 seconds 3 Select sensitivity 1 2 3 or 4 Figure 10 provides a guide for initial setup This may have to bere selected depending upon the actual application...

Страница 8: ...should periodically be observed for any signs of contamination caused by improper enclosure protection i e insure cover is fully engaged and that wire entries are properly sealed Cleaning Requirements...

Страница 9: ...31 x 50 SLOT 7 9 x 12 7 31 x 50 SLOT 31 x 50 SLOT 7 31 x 50 SLOT 7 31 x 50 SLOT 7 9 31 x 50 SLOT 7 9 31 x 50 SLOT 7 9 x 31 x 50 SLOT 7 9 x 31 x 50 SLOT 7 9 x 1 31 x 50 SLOT 7 9 x 12 31 x 50 SLOT 7 9 x...

Страница 10: ...y Switch selectable 0 5pf 2 6pf 8 3pf 18 0pf Stability 0 01pf per degree F 0 018pf per degree C 0 5pf setting Time Delay 0 25 to 15 sec single turn adj for delay to activate delay to de activate Fail...

Отзывы: