 • Make sure the unit to be installed suits the
   intended use and application.
 • Do not use any gas other than specified on the
   sticker.
 • Do not operate with any power source
   (voltage/frequency) other than specified on the
   sticker.

Verification of  the unit.

Before installation.

Ventilation
 • Install the unit where there is enough space for ventilation.
 • Do not install the unit where flammables such as gasoline, benzene, and adhesive are
   handled.
 • This unit does not allow the use of  extended exhaust pipes.
 • Install the unit as far as possible, away from anything in front or above even if  it is non-
   combustible in order to prevent exhaust gas recirculation, and staining of  surfaces.
 • Take preventive measures against snow drifts for air inlet and exhaust outlet to stay
   unaffected in case there is a possibility that they may be blocked by snow fall.

Location of  the unit.
Decide where to install the unit by considering customer’s request and clearances.

Warning

Warning

DIRECT VENT AUTOMATIC INSTANTANEOUS GAS WATER 
HEATER FOR INDOOR INSTALLATION
NATURAL GAS / PROPANE GAS

CHAUFFE-EAU INSTANTAN  AUTOMATIQUE ¸  VENT DIRECT 
POUR INSTALLATION INT RIEUR.
NAT / GPL

 

ANSI Z21.10.3-2004

CSA 4.3-2004

   

Wiring Diagram inside Front Cover
Sch ma du c blage derri re le couvercle avant.

Minimum clearances from combustible of non-combustible construction
D gagements minimaux   assurer entre les parois de l«appareil et les constuctions combustibles ou 
incombustibles

Back:  0 inch                            0 po arri re
Front:24 inches                      24 po devant d«appareil
Top:  12 inches                      12 po dessus
Side:    6 inches                        6 po c t s

FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 
appliance.
This water heater is required to have with a pressure relief valve. For safe operation of the water 
heater the relief valve must not be removed from its designated point of installation or plugged.

POUR VOTRE SÉCURITÉ
Ne pas entreposer ne utiliser d«essence ne d«autres vapeurs ou liquides inflammables   proximit  
de cet appareil ou de tout autre appareil.
Ce chauffe-eau d it  tre installer avec un soupape de d charge. Pour assurer le fonctionnement 
s curitaire du chauffe-eau, ne pas retirer ni obturer cette soupape de d charge.

PROPANE GAS  (GPL)

NATURAL GAS  (Gaz Naturel)

MODEL : MWH180EX 

180,000 Btu/h

180,000 Btu/h

MAX. INPUT
Debit calorifique max.

20,000 Btu/h

20,000 Btu/h

MIN. INPUT
Debit calorifique min.

14.0 inches W.C.

14.0 pounces W.C.

10.5 inches W.C.

10.5 pounces W.C.

GAS PRESSURE INLET MAX.
Pression de gaz entr e max. 

8.0 inches W.C.

8.0 pounces W.C.

4.0 inches W.C.

4.0 pounces W.C.

GAS PRESSURE INLET MIN. 
Pression de gaz entr e min.

3.10 inches W.C. (2.75)

3.10 pounces W.C. (2.75)

2.75 inches W.C. (2.55)

2.75 pounces W.C. (2.55)

GAS PRESSURE MANIFOLD MAX.
Pression d«admission max.

0.4 inches W.C.

0.4 pounces W.C.

0.4 inches W.C.

0.4 pounces W.C.

GAS PRESSURE MANIFOLD MIN.
Pression d«admission min.

AC 120V — 60Hz

ELECTRICAL RATING
Regime nominal  lectrique

150 PSI

MAX. WATER PRESSURE
Pression d eau max.

20511090

For the safety and the proper usage.
Read and understand "IMPORTANT ISSUES TO 
BE NOTED IN PARTICULAR" before the use.
The cases shown below are classified by the 
degree of risk and damage.
Be sure to follow the instruction for your safety.

L instruction securit  pour l usage de MWH180.
Lisez et comprendrez  Instructions de securit  
avant utilisation  avant usage.
Les situations suivant sont cat goris  par le degr  
de risque et danger.
Suivez les instructions exactement pour votre 
securit .

    Danger
 ¥ Attention au fuite de gaz. (Peut r sulter en feu)
 ¥ Ne jamais installer le chauffe-eau a l interieure 
   car il est exclusivement pour usage a l ext rieur.
 ¥ Ne pas installer dans la sale de bain. (choc 
    lectrique ou une fuite de l eau peut resulter)

    Danger
 ¥ Watch for gas leak (May cause fire.)
 ¥ Never install the unit indoors as it is exclusively
   for the outdoor use.
 ¥ Do not install it in the bathroom. Electric shock  
   or leakage may result.

    Avertissement
 ¥ Attention a pr venier des br lures.
 ¥ Confirmez le type de gaz et la puissance 
    lectrique.
 ¥ Payez attention aux enfants. (pr venir des 
   br lures)
 ¥ Pas de  d montage, r paration ou modification. 
   ( tre cause du feu, choc  lectrique ou d outre  
   accidents)
 ¥ Ne pas place des mat riaux  combustible pr s 
   du chauffe-eau.
 ¥ Ne touchez pas le chauffe-eau pendant
   op ration ou juste apr s terminer l op ration.
 ¥ N employez aucun gaz autre que sp cifique 

    

sur l tiquette.

    Warning
 ¥ Caution to prevent scalding.
 ¥ Confirm type of gas and power supply.
 ¥ Pay attention to children. (Cause of accident.)
 ¥ No disassembly, repair or modification. (May 
   cause fire, electric shock or other accidents.)
 ¥ Caution for flammable items.
 ¥ Do not touch water heater during or immediately
   after operation.
 ¥ Do not use any gas other than specified on the 
   sticker.

MWH180EX

 ONLY FOR USE WITH

 REFER TO THE LOCAL GAS AUTHORITY FOR CONFIRMATION ON THE GAS TYPE, IF IN DOUBT.
 DO NOT REMOVE THIS LABEL UNTIL THE APPLIANCE HAS BEEN INSTALLED AND TESTED
 

Si vous ne savez pas le type de gaz, contactez le fournisseur de gaz ou les autorit  locaux.

 Enlevez pas cette etiquette jusqu«  l«appareil a  t   installer et verifie.

NATURAL GAS

SERIAL NUMBER

Manufactured for: MONITOR PRODUCTS INC.    Ref.: New Jersey

20511040

DIRECT VENT AUTOMATIC INSTANTANEOUS GAS WATER 
HEATER FOR INDOOR INSTALLATION
NATURAL GAS / PROPANE GAS

CHAUFFE-EAU INSTANTAN  AUTOMATIQUE ¸  VENT DIRECT 
POUR INSTALLATION INT RIEUR.
NAT / GPL

 

ANSI Z21.10.3-2004

CSA 4.3-2004

   

Wiring Diagram inside Front Cover
Sch ma du c blage derri re le couvercle avant.

Minimum clearances from combustible of non-combustible construction
D gagements minimaux   assurer entre les parois de l«appareil et les constuctions combustibles ou 
incombustibles

Back:  0 inch                            0 po arri re
Front:24 inches                      24 po devant d«appareil
Top:  12 inches                      12 po dessus
Side:    6 inches                        6 po c t s

FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 
appliance.
This water heater is required to have with a pressure relief valve. For safe operation of the water 
heater the relief valve must not be removed from its designated point of installation or plugged.

POUR VOTRE SÉCURITÉ
Ne pas entreposer ne utiliser d«essence ne d«autres vapeurs ou liquides inflammables   proximit  
de cet appareil ou de tout autre appareil.
Ce chauffe-eau d it  tre installer avec un soupape de d charge. Pour assurer le fonctionnement 
s curitaire du chauffe-eau, ne pas retirer ni obturer cette soupape de d charge.

PROPANE GAS  (GPL)

NATURAL GAS  (Gaz Naturel)

MODEL : MWH180EX 

180,000 Btu/h

180,000 Btu/h

MAX. INPUT
Debit calorifique max.

20,000 Btu/h

20,000 Btu/h

MIN. INPUT
Debit calorifique min.

14.0 inches W.C.

14.0 pounces W.C.

10.5 inches W.C.

10.5 pounces W.C.

GAS PRESSURE INLET MAX.
Pression de gaz entr e max. 

8.0 inches W.C.

8.0 pounces W.C.

4.0 inches W.C.

4.0 pounces W.C.

GAS PRESSURE INLET MIN. 
Pression de gaz entr e min.

3.10 inches W.C. (2.75)

3.10 pounces W.C. (2.75)

2.75 inches W.C. (2.55)

2.75 pounces W.C. (2.55)

GAS PRESSURE MANIFOLD MAX.
Pression d«admission max.

0.4 inches W.C.

0.4 pounces W.C.

0.4 inches W.C.

0.4 pounces W.C.

GAS PRESSURE MANIFOLD MIN.
Pression d«admission min.

AC 120V — 60Hz

ELECTRICAL RATING
Regime nominal  lectrique

150 PSI

MAX. WATER PRESSURE
Pression d eau max.

20524910

For the safety and the proper usage.
Read and understand "IMPORTANT ISSUES TO 
BE NOTED IN PARTICULAR" before the use.
The cases shown below are classified by the 
degree of risk and damage.
Be sure to follow the instruction for your safety.

L instruction securit  pour l usage de MWH180.
Lisez et comprendrez  Instructions de securit  
avant utilisation  avant usage.
Les situations suivant sont cat goris  par le degr  
de risque et danger.
Suivez les instructions exactement pour votre 
securit .

    Danger
 ¥ Attention au fuite de gaz. (Peut r sulter en feu)
 ¥ Ne jamais installer le chauffe-eau a l interieure 
   car il est exclusivement pour usage a l ext rieur.
 ¥ Ne pas installer dans la sale de bain. (choc 
    lectrique ou une fuite de l eau peut resulter)

    Danger
 ¥ Watch for gas leak (May cause fire.)
 ¥ Never install the unit indoors as it is exclusively
   for the outdoor use.
 ¥ Do not install it in the bathroom. Electric shock  
   or leakage may result.

    Avertissement
 ¥ Attention a pr venier des br lures.
 ¥ Confirmez le type de gaz et la puissance 
    lectrique.
 ¥ Payez attention aux enfants. (pr venir des 
   br lures)
 ¥ Pas de  d montage, r paration ou modification. 
   ( tre cause du feu, choc  lectrique ou d outre  
   accidents)
 ¥ Ne pas place des mat riaux  combustible pr s 
   du chauffe-eau.
 ¥ Ne touchez pas le chauffe-eau pendant
   op ration ou juste apr s terminer l op ration.
 ¥ N employez aucun gaz autre que sp cifique 

    

sur l tiquette.

    Warning
 ¥ Caution to prevent scalding.
 ¥ Confirm type of gas and power supply.
 ¥ Pay attention to children. (Cause of accident.)
 ¥ No disassembly, repair or modification. (May 
   cause fire, electric shock or other accidents.)
 ¥ Caution for flammable items.
 ¥ Do not touch water heater during or immediately
   after operation.
 ¥ Do not use any gas other than specified on the 
   sticker.

MWH180EX

 ONLY FOR USE WITH

 REFER TO THE LOCAL GAS AUTHORITY FOR CONFIRMATION ON THE GAS TYPE, IF IN DOUBT.
 DO NOT REMOVE THIS LABEL UNTIL THE APPLIANCE HAS BEEN INSTALLED AND TESTED
 

Si vous ne savez pas le type de gaz, contactez le fournisseur de gaz ou les autorit  locaux.

 Enlevez pas cette etiquette jusqu«  l«appareil a  t   installer et verifie.

PROPANE GAS

SERIAL NUMBER

Manufactured for: MONITOR PRODUCTS INC.    Ref.: New Jersey

20511040

                                                                                                                 or

Содержание MWH180EX

Страница 1: ...MWH180EX Service Manual Instantaneous Gas Water Heater Residential Outdoor Unit...

Страница 2: ...PIPING 21 2 9 PRESSURE RELIEF VALVE 22 2 10 ELECTRICAL CONNECTION 22 2 11 WIRING DIAGRAM 24 2 12 DIAGNOSTIC POINTS 26 2 13 SCHEMATIC DIAGRAM 27 2 14 WIRING REMOTE CONTROLLER 28 2 15 MAIN REMOTE CONTR...

Страница 3: ...design of the combustion burners allows the value of NOx to be lower than 55 ppm 3 Self diagnostic function Detects the scale clogging of the heat exchanger assembly warning Detects the blocked exhau...

Страница 4: ...F Noise level 49dB NOx 55ppm Max Safety devices Flame failure Flame rod Over heat switch 210 F Over heat limit 203 F Thermal fuse for heat exchanger 363 F Over current fuse 5A Automatic frost protect...

Страница 5: ...0 6 0 7 0 8 0 100 95 110 120 130 140 150 160 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 100 95 110 120 130 140 150 160 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 100 95 110 120 130 140 150 160 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8...

Страница 6: ...Heat Exchanger Thermistor Manifold Assembly Flame Rod Electrode 6 Modulation Valve Unit Gas Control Assembly Over Heat Switch bi metal switch 16 26 Frost Sencing Switch bi metal switch 7 8 9 10 Combu...

Страница 7: ...ce The plunger stops moving and stays at a certain position when the Upward and Down ward force are balanced As the plunger remains at the position the valve position of the Modulating Solenoid Valve...

Страница 8: ...6 Diaphragm Plunger Plunger spring Coil LP 13A 21 21 10 20 96 5 82 OUT 2 OUT1 127 7 UP34 33C 13A Modulating Solenoid Valve Solenoid Valve Filter IN Pressure check hole...

Страница 9: ...such temperature drops If the water flow is greater than the heater capacity a signal from the PCB activates the water flow control device s motor stepping motor In response to this operation the valv...

Страница 10: ...ximately 95 000 BTU is re quired both Gas Solenoid Valve 1 and Gas Solenoid Valve 2 are opened to burn with rich and lean burners while the gas supply is controlled by the Gas Solenoid Valve When the...

Страница 11: ...The system is activated to blow the fuse at 363 F 184 C 4 Over heat switch residual Even if the heat exchanger assembly is over heated by no water combustion every gas path is closed to avoid risks A...

Страница 12: ...residual hot water is detected by the thermistor of the can body when hot water flow is stopped The criterion for judging scale build up varies depending on combustion capacity 4 LC alarm and set tem...

Страница 13: ...understand the installation manual to carry out the installation as specified for proper and safe usage A competent dealer or plumber should perform the complete installation including placement plum...

Страница 14: ...aution for flammable items Do not touch water heater during or immediately after operation Do not use any gas other than specified on the sticker MWH180EX ONLY FOR USE WITH REFER TO THE LOCAL GAS AUTH...

Страница 15: ...leaving about 1 8inches 4mm length to hook on 2 Hook the center hole of the wall hanging bracket onto the screw and securely fix the unit with 4 screws Screw for wall hanging Wall hanging bracket Scre...

Страница 16: ...one easily Secure space not only in front but also under the unit Do not install the unit over other combustion appliances such as gas cooking stove or a range Oil residue and dust in the air can adhe...

Страница 17: ...sliding window Do not install the unit so that the exhaust gas directly hits against any reinforced glass plate The glass may crack or break due to the exhaust heat Do not install the unit near plants...

Страница 18: ...16 23 1 32 585mm 22 5 8 575mm 13 25 32 350mm 3 15 16 100mm 2 3 8 60mm 1 5 16 33 5mm 4 15 32 113 5mm 3 13 16 97mm 2 25 32 71mm 3 9 16 97mm 1 31 32 50mm 6 1 2 165mm 19 32 15mm 15 32 12mm 2 2 DIMENSIONS...

Страница 19: ...ve Valve 3 Valve 4 Pressure relief valve Drain Union Union Union This drawing is intended only as a guide It does not imply compliance with local building codes Installation must be done in accordance...

Страница 20: ...supply Union Shut off valve Union This drawing is intended only as a guide It does not imply compliance with local building codes Installation must be done in accordance with local building codes and...

Страница 21: ...ches 15cm for appliances 10 000 Btuh 3kW 9 inches 23cm for appliances 10 000 Btuh 3kW and 50 000 Btuh 15kW 12 inches 30cm for appliances 50 000 Btuh 15kW 6 inches 15cm for appliances 10 000 Btuh 3kW 9...

Страница 22: ...7 5 2 6 9 5 5 9 0 5 1 7 4 0 4 4 5 1 4 3 9 3 0 2 3 7 7 2 2 4 3 9 2 8 7 0 2 8 9 6 1 2 7 4 1 7 1 3 1 3 0 2 1 4 1 1 1 2 4 0 1 3 8 9 3 3 9 2 6 7 1 6 6 e z i S e p i P t e e F n i h t g n e L 0 1 0 2 0 3 0...

Страница 23: ...sten tightly Make sure to conduct gas leakage test before operating MWH 180EX 2 7 GAS PIPING 2 8 WATER PIPING Install a manual water control valve in the water inlet connection of MWH 180EX A union sh...

Страница 24: ...nstall any depressurizer or restriction device in the relief line Manually operate the pressure relief valve at least once a year to check if it functions properly 2 10 ELECTRICAL CONNECTION MWH 180EX...

Страница 25: ...tivate resulting in possible freezing damage Do not let the power cord contact the gas piping The grounding screw is located in the junction box attached to the outside of bottom plate To prevent elec...

Страница 26: ...24 2 11 WIRING DIAGRAM...

Страница 27: ...25...

Страница 28: ...g n i v l o v e R e u l B e g n a r O V 6 2 C D n o i t i d n o C g n i v l o v e R e u l B e t i h W V 2 1 8 C D n o i t i d n o C g n i v l o v e R d o R e m a l F 3 n e e r G e t i h W V 0 5 1 0 5...

Страница 29: ...lve Solenoid Valve SV1 Burner Water Filter Water Flow Control Device Igniter Thermal Fuse Over Heat Switch Outgoing Thermistor Surge Protector PCB Fan Motor Flame Rod Remote Controller Heat Exchanger...

Страница 30: ...l only depending on the distance from MWH 180EX to the remote controllers Remote controller connection terminals Remote controller cable Cable clamp The appliance should always be disconnected from th...

Страница 31: ...ve a combustion appliance like hot plate or a kitchen range The heat will cause electrical component problems or deform the exterior Install Main remote controller out of the reach of steam water drop...

Страница 32: ...covers with catching the bottom corner s slot with nail Do not tighten the screws excessively as the screw hole may be damaged In case of mounting the remote controller on tile cement or mortar use a...

Страница 33: ...tion or the unit will not be used for an extended time the residual water in the unit and the pipe may freeze and damage the unit or the residual water in the heat exchanger may deteriorate Be sure to...

Отзывы: