Turning the meter off and on 

 

If the meter is powered by your transceiver power supply, it will simply go off when the transceiver goes 
off  and  come  on  again  when  the  transceiver  comes  on.  No  power  switching  of  the  meter  is  needed.  If 
however you are powering the meter from a source that is always on, you may wish to switch the meter 
off and on independently. The meter allows you to do this. To switch off, hold the button until the menu 
screen appears, then keep the button pressed until the “goodbye” screen appears, then release. To restart 
the meter, momentarily press the button. Interrupting the power supply will also restart the meter. 

 
 

Using the Menu 

 

The menu enables the operator to adjust the brightness of the display and to set-up the alarm parameters. 
To enter the menu, hold the button until the menu screen appears and then release immediately. Holding 
the button for longer causes the meter to turn off. 

 

This is followed by the help screen. It reminds you how the menu works. A quick press will move to the 
next  item.  A  long  press  will  change  the  displayed  item.  Note  that  the  help  screen  is  only  shown  once  in 
each session. 

 

The first menu item allows you to adjust the screen brightness in four stages to suit the ambient lighting in 
your shack. Brightness 1 is quite dim, rising to brightness 4, the brightest. 

 

 The high SWR warning and alarm screens are at full brightness and independent of the brightness setting. 
When the brightness number is at the desired level, a short press will skip to the next item. 

The second menu item turns on or off the high SWR alarm. When the meter leaves the factory, the alarm is 
turned off. If the alarm is not to be used, there are no further menu items and a short press will leave the 
menu. 

 

Содержание Power + SWR

Страница 1: ...a good place to connect the meter supply The red wire must go to the positive and the black to negative If a mistake is made an internal series diode will prevent damage to the meter Note the negative supply is grounded in the meter RF connections The SO239 co ax socket marked RF IN should be connected to your transceiver or linear amplifier This is the input to the meter The other SO239 socket ma...

Страница 2: ...otally reflected back to the transmitter where it may be doing harm The second line of the display indicates the standing wave ratio This value is also dependent on the forward and reverse power flows through the meter When the numbers are replaced with dashes it means there is insufficient power to calculate the SWR A perfect match would produce a value of 1 00 1 which would be seldom seen in pra...

Страница 3: ...suspended while the tuning screen is in use Operating using CW AM Data and SSB The meter will automatically recognise CW AM Data and SSB signals It will read the carrier level of a tune signal data signal or CW signal It will read the PEP power of an SSB signal It will read the carrier power of an AM signal when unmodulated and the PEP power of a modulated AM signal When a PEP measurement is being...

Страница 4: ...ter the menu hold the button until the menu screen appears and then release immediately Holding the button for longer causes the meter to turn off This is followed by the help screen It reminds you how the menu works A quick press will move to the next item A long press will change the displayed item Note that the help screen is only shown once in each session The first menu item allows you to adj...

Страница 5: ... manually reset or auto reset In manual reset when the SWR alarm threshold is exceeded the relay changes state This will normally cause the transmitter to be cut off depending on the external wiring to the alarm contact The relay will remain in this condition until the button is pressed If auto reset is selected the meter resets the alarm after 3 minutes and again after 6 minutes If the fault has ...

Страница 6: ...ggered and the transmitter turned off The meter will try again in a further 3 minutes If both retries are failures the alarm is locked on until manually reset by pressing the button If the fault condition has cleared the transmitter will continue normal operation and the screen color will revert to normal Additional notes If the screen becomes blue it means the power rating of the meter is being e...

Страница 7: ...nstrument is individually calibrated at the factory Expect Power measurements to be better than 5 over most of the power and frequency range SWR readings are calculations based on the same input data and have similar accuracy Modulation modes CW SSB AM FM RTTY Data modes WSPR FST4 JT9 etc SSB is auto detected and PEP measurements are applied where necessary Max Power handling 2000 Watts for the HF...

Страница 8: ...the works providing there is no evidence of abnormal use The obligation under the warranty is limited to replacing or repairing at our option any of the items so determined to be defective The warranty shall not apply to any item that has been repaired or altered by others or which has been subjected to misuse Customers should contact our service department before returning goods service monitorse...

Отзывы: