Monitor Sensors Power + SWR Скачать руководство пользователя страница 1

 

 

 

 

Connecting the Power + SWR Meter 

 

DC Power connection 
 
The power lead supplied with the meter mates with the black DC jack on the rear panel of the meter. The 
other  end  of  the  cable  ends  in  tinned  wires  marked  red  and  black.  These  need  to  be  connected  to  the 
station 12 Volt supply, or indeed any DC power supply in the range 6 to 16 Volts. Some transceivers have a 
switched 12 Volt outlet for accessories. This would also be a good place to connect the meter supply. The 
red wire must go to the positive and the black to negative. If a mistake is made, an internal series diode will 
prevent damage to the meter. Note the negative supply is grounded in the meter. 

RF connections 

 

The SO239 co-ax socket marked “RF IN” should be connected to your transceiver or linear amplifier. This is 
the input to the meter. The other SO239 socket marked “RF OUT” is the output of the meter and should be 
connected  to  your  antenna  matching  unit,  which  in  turn  is  connected  to  the  antenna.  If  there  is  no 
matching unit, connect the antenna directly to the “RF OUT” SO239 socket. 

Содержание Power + SWR

Страница 1: ...a good place to connect the meter supply The red wire must go to the positive and the black to negative If a mistake is made an internal series diode will prevent damage to the meter Note the negative supply is grounded in the meter RF connections The SO239 co ax socket marked RF IN should be connected to your transceiver or linear amplifier This is the input to the meter The other SO239 socket ma...

Страница 2: ...otally reflected back to the transmitter where it may be doing harm The second line of the display indicates the standing wave ratio This value is also dependent on the forward and reverse power flows through the meter When the numbers are replaced with dashes it means there is insufficient power to calculate the SWR A perfect match would produce a value of 1 00 1 which would be seldom seen in pra...

Страница 3: ...suspended while the tuning screen is in use Operating using CW AM Data and SSB The meter will automatically recognise CW AM Data and SSB signals It will read the carrier level of a tune signal data signal or CW signal It will read the PEP power of an SSB signal It will read the carrier power of an AM signal when unmodulated and the PEP power of a modulated AM signal When a PEP measurement is being...

Страница 4: ...ter the menu hold the button until the menu screen appears and then release immediately Holding the button for longer causes the meter to turn off This is followed by the help screen It reminds you how the menu works A quick press will move to the next item A long press will change the displayed item Note that the help screen is only shown once in each session The first menu item allows you to adj...

Страница 5: ... manually reset or auto reset In manual reset when the SWR alarm threshold is exceeded the relay changes state This will normally cause the transmitter to be cut off depending on the external wiring to the alarm contact The relay will remain in this condition until the button is pressed If auto reset is selected the meter resets the alarm after 3 minutes and again after 6 minutes If the fault has ...

Страница 6: ...ggered and the transmitter turned off The meter will try again in a further 3 minutes If both retries are failures the alarm is locked on until manually reset by pressing the button If the fault condition has cleared the transmitter will continue normal operation and the screen color will revert to normal Additional notes If the screen becomes blue it means the power rating of the meter is being e...

Страница 7: ...nstrument is individually calibrated at the factory Expect Power measurements to be better than 5 over most of the power and frequency range SWR readings are calculations based on the same input data and have similar accuracy Modulation modes CW SSB AM FM RTTY Data modes WSPR FST4 JT9 etc SSB is auto detected and PEP measurements are applied where necessary Max Power handling 2000 Watts for the HF...

Страница 8: ...the works providing there is no evidence of abnormal use The obligation under the warranty is limited to replacing or repairing at our option any of the items so determined to be defective The warranty shall not apply to any item that has been repaired or altered by others or which has been subjected to misuse Customers should contact our service department before returning goods service monitorse...

Отзывы: