4. Testing the Compact Hopper
Ensure the power supply is OFF and the “HOPPER / ON” switch is set to “HOPPER”.
Once all connections have been made, set the “ CONT / PULSE” and the “FREE / COUNT”
switches to the desired test positions:-
4.1
CONT / FREE
Switch on the power supply.
The display will show the following:-
The left hand side of the display (COUNTER) shows how many coins have been paid out
while the right hand side (CURRENT) shows the current being drawn by the hopper.
Switch “HOPPER / ON” to “ON” to start the hopper paying out.
The display will show the following:-
As each coin is paid out, the counter will increment by 1 and the “OPTO” LED will flash.
The hopper will continue to run even when all the coins are paid out.
To stop the hopper, switch “HOPPER / ON” to “HOPPER”.
The display will show:-