14. Alarms
When enabled, an alarm condition will activate all the outputs (A1 to A6) for 100ms, except for
condition iii.
Conditions which will indicate an alarm condition include:
i.
An event which occurs out of sequence.
ii.
A sequence of events occur which indicate a ‘Coin-on-string’ fraud is being attempted.
There are a number of events that might lead to this condition.
iii. If the credit / reject sensor is blocked for more than 1.5 seconds, the alarm signal will
remain active, for the duration of the blockage.
iv.
During power-up diagnostics – if enabled.
14.1 Enable
To enable an alarm the following steps should be followed:
Switch off the power to the SR3.
SW1
SW2
SW3
SW4
SW5
SW6
ON
OFF
OFF
ON
OFF
OFF
Switch on the power to the SR3.
Press the reject lever within 20 seconds.
The LED will flash GREEN.
Switch off the power to the SR3.
Set all switches OFF.
Switch on the power to the SR3.
The alarm is now ON.
14.2 Disable
To disable an alarm the following steps should be followed:
Switch off the power to the SR3.
SW1
SW2
SW3
SW4
SW5
SW6
OFF
OFF
OFF
ON
OFF
OFF
Switch on the power to the SR3.
Press the reject lever within 20 seconds.
The LED will flash GREEN.
Switch off the power to the SR3.
Set all switches OFF.
Switch on the power to the SR3.
The alarm is now OFF.