FLAME APPEARANCE
CHECKING BURNER FLAME
VFC24L/VFC32L MODELS
In normal operation at full rate after 15 minutes, the
following flame appearances should be observed:
Burner will have a random pattern of yellow flames. Figure
34 There should be glowing embers in front of burner.
NOTE: The front flames and embers will be an opaque
orange color during the burn off time.
VFC24C/VFC32C MODELS
In normal operation at full rate after 15 minutes, the
following flame appearances should be observed:
Burner will have a random pattern of yellow flames. Figure
35
Figure 34.
VFC Traditional Flame Appearance
Figure 35.
VFC Contemporary Flame Appearance
OPERATING INSTRUCTIONS
Avoid any drafts that alter burner flame patterns.
Do
not allow fans to blow directly into the fireplace. Do not
place a blower inside the burn area of the firebox. Ceiling
fans may create drafts that alter flame patterns. Sooting
and improper burning will result.
During manufacturing, fabricating and shipping, various
components of this appliance are treated with certain oils,
films or bonding agents. These chemicals are not harmful,
but may produce annoying smoke and smells as they are
burned off during the initial operation of the appliance,
possibly causing headaches or eye or lung irritation.
This
is a normal and temporary occurrence.
The initial break-in operation should last two to three hours
with the burner at the highest setting. Provide maximum
ventilation by opening windows or doors to allow odors to
dissipate. Any odors remaining after this initial break-in will
be slight and will disappear with continued use.
This appliance must not be used with glass doors in the
closed position. This can lead to pilot outages and severe
sooting outside the fireplace.