
8
61D1013
9"
Minimum
42"
Minimum
9"
Minimum
Ensure that minimum clearances shown in Figures 4 through 7 are maintained. Left and right clearances are determined
when facing the front of the firebox.
Follow these instructions carefully to ensure safe installation. Failure to follow these requirements may create a
fire hazard.
1.
Sidewall clearances:
The clearance from the inside of the appliance to any combustible wall should not be
less than 9".
See Figure 4.
2.
Ceiling clearance:
The ceiling must be at least 42” from the top of the firebox opening.
See Figure 4.
3.
Back wall clearnace:
The appliance may be placed against a combustible back wall.
Figure 4 - Clearance and Height Requirements
Continued on page 10
CLEARANCES
AND
HEIGHT REQUIREMENTS