6
70D0004
PRODUCT FEATURES
AND
SPECIFICATIONS
NATURAL GAS
NOTE: An external regulator is required to reduce supply pressure to a maximum of 10
1
/
2
" W.C. on
natural gas systems operating at higher pressure.
MILLI-VOLT
Regulator Pressure Setting: 3.5" w.c.
Pilot Regulator:
3.5" w.c.
Gas Inlet Pressure:
Max 10
1
/
2
" w.c.
Min. 5" w.c.
PROPANE/LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
MILLI-VOLT
Regulator Pressure Setting: 10" w.c
Gas Inlet Pressure:
Max. 13" w.c.
Min. 11" w.c.
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Milli-Volt control has four (4) positions:
OFF
- All gas to the gas logs is shut off at the valve.
IGN
- Valve position to light/maintain a standing pilot.
ON
- Valve position to turn ON/OFF log set with remote switch/thermostat.
LOW/HI
- Variable position to control flame height (heat output).
PILOT/ODS
The gas log heater is fitted with a specially designed safety pilot (ODS assembly) which senses the amount of oxygen avail-
able in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot can
only be relit when adequate fresh air is available.
THERMAL GENERATOR
The millivolt gas log pilot is fitted with a milli-volt (thermopile) generator to provide power for remote activation.
Model Number
Control
Gas Rate
Max BTU/Hr
Min BTU/Hr
TPB18NV
Milli-Volt
28,000
19,000
TPB24NV
Milli-Volt
38,000
26,000
TPB30NV
Milli-Volt
38,000
26,000
Model Number
Control
Gas Rate
Max BTU/Hr
Min BTU/Hr
TPB18PV
Milli-Volt
28,000
23,000
TPB24PV
Milli-Volt
34,000
26,000
TPB30PV
Milli-Volt
34,000
26,000
Содержание TPB18