Monessen Hearth MJ22NIF/PIF Скачать руководство пользователя страница 35

35

Monessen  • Mojo Installation/Owner’s Manual  •  4623-900  Rev. D  • 04/21

FIREPLACE STATUS

THERMOSTAT 

THERMOSTAT DESIRED 

TEMP SETTING

FLAME HEIGHT

TIMER DISPLAY/FUNCTION

ROOM TEMP 

DISPLAY

LOW BATTERY

INDICATOR

TRANSMISSION

INDICATOR

CHILD LOCK 

INDICATOR 

Function Buttons

Menu

Select

V

V

Use POWER button to turn the unit on and off.  

Use MENU button to display the menu functions.  

Only  functions  that  can    be  activated  will  be 

displayed.  

For example: Flame Height will not 

be displayed when the remote status is OFF.

   

Use  the  SELECT  button  to  select  the  current 

feature.

Use  the  UP  and  DOWN  arrows  to  toggle 

through  the  menu  functions  and  value  selec

-

tions in the submenus.  

Idle When Remote is in ON Mode

The  remote  control  will  go  into  an  idle  mode  if  no  but

-

tons are pressed within 5 seconds. Press any button to 

resume full functionality. In idle mode, only active func

-

tions will show on the screen.

Standby mode

The remote control will go into a standby mode if no but

-

tons  are  pressed  within  5  minutes.  Press  the  POWER 

button to reactivate the remote control to ON mode. Ac

-

tive functions will be displayed

Menu

Select

V

V

Menu

Select

V

V

Menu

Select

V

V

Menu

Select

V

V

Display Screen 

Figure 8.  RC300 Display Screen

Figure 9.  RC300 Idle Mode

Figure 10.  RC300 Standby Mode

Содержание MJ22NIF/PIF

Страница 1: ...PLOSION HAZARD If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life This is an unvented gas fired heater It...

Страница 2: ...ormation A General Information 17 B Wiring Requirements 18 C Detailed Component Operating Instructions IntelliFire Plus with ODS Battery Only 19 6 Gas Log Sets A Place Rock Wool 20 B Log Placement 21...

Страница 3: ...remain visible at all times on the appliance until the installation is complete This standard work checklist is to be used by the installer in conjunction with not instead of the instructions contain...

Страница 4: ...dels Maximum Input BTU h Minimum Input BTU h Orifice MJ22NIF 0 2000 FT 29 000 21 000 38 MJ22PIF 0 2000 FT 28 000 23 000 52 MJ27NIF 0 2000 FT 38 000 27 000 32 MJ27PIF 0 2000 FT 37 000 29 000 1 9 mm GAS...

Страница 5: ...ure Gloves Voltmeter Manometer Phillips screwdriver Safety glasses Flat blade screwdriver Soapy water solution for gas leak testing Electric drill and bits 1 4 in magnetic External regulator for propa...

Страница 6: ...een design certified for these installations Exception DO NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with u...

Страница 7: ...easing the ambient temperature inside the fireplace Placement of the receiver outside of the fireplace will extend the battery life Barriers such as the bottom of a glass door frame placed in front of...

Страница 8: ...water vapor retarder with a rating of 1 perm 6 x 1011 kg per pa sec m2 or less with openings gasketed or sealed and b Weather stripping has been added to windows and doors and c Caulking or sealants...

Страница 9: ...re This Distance Heater in Fireplace Firebox Figure 3 2 Measure Non Combustible Material Table A Non Combustible Material Requirements with No Mantel or Combustible Projection Non Combustible Material...

Страница 10: ...ombustible Projection MJ22 MJ27 12 or more Hood not required Observe profiles side elevations shown in Figure 3 6 Hood not required Observe profile side elevations shown in Figure 3 6 8 or less than 1...

Страница 11: ...21 2 at a minimum of 14 above the opening and a maximum of 6 at a minimum of 201 2 above the opening Figure 3 4 Minimum Mantel Clearance with No Hood MJ22 Non combustible Material Heater in Fireplace...

Страница 12: ...r if a minimum of 14 of noncombustible material such as slate or marble is installed between the base of the fireplace and the combustible flooring Figure 3 8 Figure 3 7 Minimum Clearance above Combus...

Страница 13: ...t resistant sealant Install and operate the appliance as directed in this manual Damper stop installation for vented application Adamper stop must be provided with the unit Contact your dealer to obta...

Страница 14: ...p Anchor the engine assembly using the two 2 supplied 1 4 hex head fasteners through the holes previously drilled You must secure the gas log heater to the fireplace floor If not the entire unit may m...

Страница 15: ...ter solution after completing connection DO NOT USE AN OPEN FLAME Check the gas pressure with the appliance burning and the control set to HIGH Use new black iron or steel pipe Internally tinned coppe...

Страница 16: ...WARNING Risk of Fire or Explosion High pressure will damage valve Low pressure could cause explosion Verify inlet pressures Verify minimum pressures when other household gas appliances are operating...

Страница 17: ...OT wire 110 120 VAC to the valve or to the appliance wall switch Incorrect wiring will damage controls NOTICE This appliance must be electrically wired and grounded in accordance with local codes or i...

Страница 18: ...Diagram This appliance is equipped with an IntelliFire Plus with ODS control valve which operates on a 6 volt 1 5 AMP system Install 4AA cell batteries into the battery pack before use See Figure 5 1...

Страница 19: ...e remote 5 Battery life will be shortened if the flame adjustment feature is used frequently on the RC300 remote control 6 Module Reset This module may lock out under certain conditions When this occu...

Страница 20: ...or embellishments such as pine cones vermiculite or rock wool to the heater Only use rock wool supplied with the unit Failure to position the parts in accordance with diagrams below or to use only pa...

Страница 21: ...the two pins located in the middle of the burner pan The log will set at a slight angle Figure 6 5 4 Place log 3 at an angle over log 2 toward the back by matching the rectangular notch on the bottom...

Страница 22: ...over the metal bracket located to the left side of the burner Figure 6 9 LG548 MLDV log 6 Log 6 8 Place log 7 between the second and third right tong on the grate as shown in Figure 6 10 LG549 MLDV l...

Страница 23: ...ms or bonding agents These chemicals are not harm ful but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance possibly causing headaches or eye o...

Страница 24: ...EXPLOSION HAZARD If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life This is an unvented gas fired heater I...

Страница 25: ...ed for future reference We suggest that you keep it with your other important documents and product manuals The information contained in this owner s manual unless noted otherwise applies to all model...

Страница 26: ...zed HHT dealer or distributor whichever occurs earlier However the Warranty coverage shall commence no later than 24 months following the date of Product shipment from HHT regardless of the installati...

Страница 27: ...or handling devices such as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components not sup...

Страница 28: ...stall an adjustable safety gate to keep toddlers young children pets and other at risk individuals out of the room and away from hot surfaces Install a switch lock or a wall remote control with child...

Страница 29: ...21 11 2 Unvented Heaters latest edition and ANSI Z21 60 2012 CSA2 26 2012 12 Do not install the heaters in a bathroom or bedroom 13 Correct installation of the logs proper location of the heater and a...

Страница 30: ...be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa 22 The appliance must be isolated from gas supply piping sy...

Страница 31: ...L MJ22NIF PIF MJ27NIF PIF LABORATORY Underwriters Laboratories Inc UL TYPE Unvented Room Heater STANDARD ANSI Z21 11 2 2016 Unvented Application ANSI Z21 60 2017 CSA 2 26 2017 Decorative Gas Appliance...

Страница 32: ...his label If you do not smell gas go to next step 3 To light the burner Equipped with wall switch Turn ON OFF switch to ON Equipped with remote or wall control Press ON or FLAME button Equipped with t...

Страница 33: ...te room The remote control must be placed within 30 feet 9 14 m of the heater but should not be exposed to extreme heat The RC300 is approved for interior installation and should not be used in exteri...

Страница 34: ...e Control Module CAUTION Risk of burns DO NOT program the remote control to the control module when heater is hot Verify the ON OFF REMOTE switch is in the REMOTE position Green LED light will blink t...

Страница 35: ...select the current feature Use the UP and DOWN arrows to toggle through the menu functions and value selec tions in the submenus Idle When Remote is in ON Mode The remote control will go into an idle...

Страница 36: ...ter will turn back on after the RT drops below the ST NOTICE The system requires a two degree Fahrenheit or higher temperature difference between RT and ST for the heater to turn on NOTICE The system...

Страница 37: ...ned your gas log set will give you many years of trouble free service Contact your dealer to answer questions regarding proper operation trouble shooting and service for your appliance Visit www mon e...

Страница 38: ...skin becomes irritated wash gently with soap and water Refer to manual for correct log placement Turn off heater and allow to cool before cleaning WARNING PERIODIC CLEANING Refer to parts diagram for...

Страница 39: ...e is no noise or spark A Depleted batteries or batteries installed incorrectly Battery power supply voltage must be at least 4 9 volts If less than 4 9 volts replace batteries B A shorted or loose con...

Страница 40: ...ut to metal chassis pilot burner pilot enclosure or screen if present or any other metal object B Poor flame rectification or contaminated flame sensing rod Verify correct pilot orifice is installed a...

Страница 41: ...ler or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 1 Log Support Assembly SRV4614 005 2 Burner Assembly SRV4614 001 Y 3 Grate Assembly SRV4614 004 4 Thermocouple Module SRV20303...

Страница 42: ...S PART NUMBER 8 Nut 3 8 24 UNF 3 16 Tube SRV00F0077 9 Ferrule 3 16 Tube SRV00F0078 10 Pilot ODS NG SRV14D0473 Y Propane SRV14D0477 Y Venturi Gasket SRV45D0032 Y 11 Injector NG 38 SRV33D5040 Propane 52...

Страница 43: ...or Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 1 Log Support Assembly SRV4614 006 2 Burner Assembly SRV4614 003 Y 3 Grate Assembly SRV4614 007 4 Thermocouple Module SRV20303179 Y 5 Control...

Страница 44: ...istributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 8 Nut 3 8 24 UNF 3 16 Tube SRV00F0077 9 Ferrule 3 16 Tube SRV00F0078 10 Pilot ODS NG SRV14D0473 Y Propane SRV14D0477 Y Venturi Gasket...

Страница 45: ...comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed MASSACHUSETTS RESIDENTS ONLY 2 Ap...

Страница 46: ...Monessen Mojo Installation Owner s Manual 4623 900 Rev D 04 21 46 This Page Intentionally Left Blank...

Страница 47: ...___________________________________ ________________________________________________________________________________ DO NOT DISCARD THIS MANUAL NOTICE Leave this manual with party responsible for use...

Отзывы: