20

53D9051. Rev 1 03/03

C

HIMNEY

 C

AP

 I

NSTALLATION

M

ODEL

 SC C

HIMNEY

 C

AP

S

PECIAL

 N

OTE

The proper height as previously explained is important to assure proper draft and safety.  The

chimney cap extends the flue outlet four inches above the top of the last section of chimney.  This should be
kept in mind when determining the proper height for the chimney.  The chimney should not be extended more
than 90 inches above the supporting roof structure without additional support.  In the case of an “A” frame type
construction or other steep pitch roofs that require more than 90 inches of chimney above the roof, a support
should be attached to the chimney at the 90 inch level that is strong enough to support a wind load of 3-1/8
pounds for each inch the chimney extends above 90 inches.  The flue outlet must be a minimum of three feet
above the point where it penetrates the roof.   See Figure 12.

C

AUTION

:

  Be careful to avoid electrical shock hazard when contacting wires to the metal chimney components.

1. Extend the regular chimney sections until the top of the chimney is 4 inches below the total flue height

desired.  Do not snap the last section of inlet air duct or largest diameter pipe in place until Step 3 is
completed.

2. Remove the shingles from around the chimney so that the flashing may be installed, with the upper part of

the flashing under the shingles.

3. Set the flashing on the roof and scribe a line around the flashing, then cut the top off the flashing by cutting

1/4 inch below the scribed line.  This should increase the diameter of the flashing outlet sufficiently to allow
the flashing to be placed over the chimney.   See Figure 18.

4. Snap the last section of inlet air duct in place and slide the flashing over the chimney.  Adjust the chimney

to assure that the proper minimum clearances are maintained.

5. Nail the flashing securely in place with eight nails.
6. Seal the crack between the top of the flashing and the chimney with mastic.  Leave some excess mastic at

this area to be used in step eight.  NOTE:  Use pliers and wear gloves when performing step seven to
minimize the danger of cutting your hands on the edge of the storm collar.

7. Place the storm collar around the chimney and put the collar together like a belt in belt loops.  Slide the end

of collar under the two loops on the other end with the loops facing up.  Overlap the ends of the collar until
it is tight against the chimney.  Bend the free end of the collar back over the loops to hold the storm collar
securely together.  The excess end of the storm collar may be trimmed off.

8. Slide the storm collar down snugly against the flashing until the excess mastic left in step six is forced up

into the crack between the storm collar and the chimney.  This should make the joint between the flashing
and the chimney watertight.

9. Install the chimney cap by placing the cap into matching parts of the last chimney section.  Push down until

the brackets on the bottom of the chimney cap sits on the chimney pipe.  Then punch or drill 1/8 inch
diameter holes in the inlet air duct (chimney pipe) where specified on the brackets and fasten it down with
the No. 8 screws provided.  Do not penetrate the inner stainless steel pipe while installing the screws.

10. Check all the parts of the fireplace, chimney and chimney termination cap to assure that no parts have

been damaged or bent during installation and that all parts have been installed properly.

N

OTE

 The metal used for the chimney cap has a rust protective coating but the cut edges of the parts are not

protected.  To prevent rusting and rust staining of nearby structures, exposed parts of the chimney and chimney
cap should be detergent washed and painted with a galvanized primer paint.

f i r e - p a r t s . c o m

Содержание Corner Fireplace 624WBCL

Страница 1: ...NTIAL INSTALLATION 53D9051 Rev 1 03 03 36 INCH BUILT IN WOOD BURNING CORNER FIREPLACE WITH OPTIONAL OUTSIDE AIR AND GLASS DOORS WARNING THIS FIREPLACE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET TO REDUCE RISK OF FIRE OR INJURY DO NOT INSTALL AN UNVENTED GAS LOG SET INTO FIREPLACE fire parts com ...

Страница 2: ...ry built fireplace properly can result in a house fire or other occurences that could cause deaths injuries and property damages It is very important that the persons installing and or supervising the installation of this fireplace have appropriate skills in using the tools and techniques required and reading and comprehension skills sufficient to read and follow these instructions These instructi...

Страница 3: ...d to sit directly on a combustible floor The fireplace can be installed with zero clearances to combustible building materials at the side back and top spacers Only parts manufactured by Monessen Hearth Systems and labeled for use with this fireplace should be used in the installation of the fireplace except for special roof flashings that may be fabricated locally The use of improper parts in the...

Страница 4: ...of this manual pertaining to outside combustion air assembly The fireplace also is equipped with a flue damper which must be open when the fireplace is in use The flue damper control lever is located inside the fireplace The counterweighted damper is operated by simply pushing up to open or pulling down to close the damper When the fireplace is not in use the damper should be closed to prevent col...

Страница 5: ...5 6 CLEARANCES 53D9051 Rev 1 03 03 fire parts com ...

Страница 6: ...chimney cap for contemporary installations Includes storm collar SCL Round telescoping chimney cap SQL8 Square telescoping chimney cap 612 0 6 12 pitch flashing for contemporary installation One required with SC round chimney cap on 0 6 12 pitch roof 1212 6 12 12 12 pitch flashing for contemporary installation One required with SC round chimney cap on 6 12 12 12 pitch roof SF 14 1 2 inch firestop ...

Страница 7: ...7 53D9051 Rev 1 03 03 FIREPLACE INSTALLATION fire parts com ...

Страница 8: ...S Chimney support required when chimney height exceeds 30 feet LFCC 1 Round termination cap for contemporary installation includes storm collar LFCCL 1 Round Termination cap for chase installation includes inlet air telescope 612 0 6 12 pitch flashing for contemporary installation One required with SC round chimney cap on 0 6 12 pitch roof 1212 6 12 12 12 pitch flashing for contemporary installati...

Страница 9: ...roof influences the opening size required at the roof level table 1 should be used as a guide for sizing the roof opening Proper selection of a chimney outlet location is also important Objects such as overhanging or nearby trees adjacent building or embarkments or unusual roof designs can all create air turbulance and interfere with chimney performance and cause the fireplace to spill smoke into ...

Страница 10: ...ent the crack from developing the hearth extension materials must be firmly fastened in place Wall ties should be screwed to the face of the fireplace and imbedded in the mortar joints of brick stone or other non combustible materials The metal safety strip packed with the fireplace must be placed beneath the fireplace and extended under the hearth extension or into a mortar joint of the hearth ex...

Страница 11: ...11 53D9051 Rev 1 03 03 CLEARANCES fire parts com ...

Страница 12: ...12 53D9051 Rev 1 03 03 FIREPLACE INSTALLATION fire parts com ...

Страница 13: ...13 53D9051 Rev 1 03 03 FIREPLACE INSTALLATION fire parts com ...

Страница 14: ...Check the face of the fireplace with a carpenter s level to make sure the fireplace is plumb If it is not plumb plumb it by placing shims under the edges of the fireplace 4 Block in the fireplace to prevent any shifting of the firebox Secure the fireplace with nails or screws through the flanges located on each side of the fireplace Install chimney and other fireplace components as needed NOTE Som...

Страница 15: ...tisfied with the chimney location relative to ceiling and roof joists and or any other obstructions The roof opening center line should be marked by driving a nail through the roof from underneath that will penetrate the roof and can be located from the rooftop If the chimney is to penetrate a pitched roof the hole in the roof must be rectangular instead of square and should be sized according to ...

Страница 16: ...16 CHIMNEY INSTALLATION 53D9051 Rev 1 03 03 fire parts com ...

Страница 17: ...low the inclined portions of the chimney OFFSET INSTALLATION SEQUENCE 1 Determine the location and amount of offset required then select the combinations of chimney sections and elbows required from the offset chart Refer to Table 2 2 Install the first elbow by placing the crimped end into the mating part of the fireplace or chimney section Push down until the outside or inlet air duct of the elbo...

Страница 18: ...18 CHIMNEY OFFSET AND CAP INSTALLATION 53D9051 Rev 1 03 03 fire parts com ...

Страница 19: ...19 53D9051 Rev 1 03 03 CHIMNEY OFFSET AND CAP INSTALLATION fire parts com ...

Страница 20: ...re that the proper minimum clearances are maintained 5 Nail the flashing securely in place with eight nails 6 Seal the crack between the top of the flashing and the chimney with mastic Leave some excess mastic at this area to be used in step eight NOTE Use pliers and wear gloves when performing step seven to minimize the danger of cutting your hands on the edge of the storm collar 7 Place the stor...

Страница 21: ...ough the duct See Figure 22 for methods of installing the outside air for combustion assemblies 2 The combustion air assembly should be located at an exterior location which is not likely to be accidentally blocked in any manner The assembly should be located above the snow line to prevent blockage by snow accumulation 3 The combustion air inlet assembly should never be mounted in a garage or stor...

Страница 22: ...ency and safety Do not use a combustible duct Always use UL listed Class 0 or 1 duct material 5 If the duct is the insulated type push the insulation back from one end of the duct approximately two inches See figure 25 6 Slip the exposed end of the duct over the flange tube of the fireplace 7 Place the duct clamp around the exposed end of the aluminum duct 8 Slip the band through the housing then ...

Страница 23: ...gas piping should only be installed by a licensed gas appliance installer See Figure 11 for the gas line opening dimensions on the fireplace 6 The installer should advise the persons who will use the appliance to set the fireplace damper in the full open position when the appliance is in use The following instructions only apply to passing the gas line through the fireplace wall Follow the instruc...

Страница 24: ...ld be fastened to the face of the fireplace with sheet metal screws and placed in the mortar joints of masonry trim Combustible material must not be installed below the top spacers of the fireplace or overlap the sides of the fireplace face Seal the face of the fireplace to the surrounding wall with non combustible caulk or trim materials to prevent cold air leakage around the fireplace CAUTION No...

Страница 25: ...4WBCL OR 624WBCR MODELS NON COMBUSTIBLE MAY BE INSTALLED TO THE TOP OF THE FIREPLACE OPENING THIS FACING MATERIAL MUST BE SECURED AND SEALED TO THE FACE OF THE FIREPLACE FAILURE TO PROPERLY SECURE AND SEAL NON COMBUSTIBLE FACING MATERIALS TO THE FIREPLACE CAN CAUSE A POSSIBLE FIRE HAZARD AND WILL VOID THE WARRANTY 53D9051 Rev 1 03 03 fire parts com ...

Страница 26: ...The first three fires should be of moderate size to allow the fireplace to adjust and the bricks to cure before being subjected to larger fires First make sure your room is well ventilated your damper open and the flue is unobstructed Then make sure your wood is dry and seasoned Unseasoned wood burns poorly and coupled with poor ventilation or an obstructed chimney leads to smoking problems If you...

Страница 27: ...r some individuals Use hemlock spruce juniper and other resinous woods with caution They contain moisture pockets which upon heating pop with considerable vigor Always use a fire screen And always bank a fire or at least push all unburned fuel to the rear of the grate before leaving a fire unattended Do not use this fireplace as an incinerator Because the termination of the chimney above the roof ...

Страница 28: ...ldup has occurred If creosote has accumulated it should be removed to reduce the risk of a chimney fire The chimney cap can be removed for inspection maintenance and cleaning by removing three screws from the support legs and lifting upward When the fireplace is first in use inspect the chimney frequently and clean the chimney any time an accumulation is observed on the flue walls The frequency of...

Страница 29: ... the fireplace to prevent excessive heat loss from the fireplace 5 Do trim the face of the fireplace only with noncombustible materials 6 Do attach the noncombustible face trim material firmly to the face of the fireplace 7 Do block in or fasten the fireplace to prevent the possibility of the fireplace shifting out of position 8 Do connect the air circulation blower to a properly grounded and fuse...

Страница 30: ... or place flammable liquids gases or pressurized containers near the fireplace 17 Don t neglect to instruct all responsible persons in the proper and safe operation of the fireplace 18 Don t fail to instruct all persons especially children and elderly persons concerning the hazards of improper operation and unauthorized tampering with the fireplace 19 Don t use this fireplace to burn paper cardboa...

Страница 31: ...2 Retainer 2 Z19901 3 Firebrick Side Assy Right 1 014012 4 Rod Outside Air 1 020293 5 Firebrick Back Assy 1 014048 6 Hearth Refractory 1 029986 7 Screen Panel 2 026400 8 Screen Pull 2 026391 9 Rod Screen Weld Assy 1 021673 10 Panel Upper Ptnd 1 021541 11 Rod Damper 1 037390 12 Damper Weldment 1 037393 KEY MPL MPL NO PART NAME QTY PART NO 1 Retainer Side Brick 1 020270 2 Retainer 2 Z19901 3 Firebri...

Страница 32: ...53D9051 Rev 1 03 03 ATTENTION APPLIANCE INSTALLER PLEASE RETURN THIS INSTRUCTION MANUAL TO THE CONSUMER fire parts com ...

Отзывы: