PRODUCT SPECIFICATIONS
NATURAL GAS
NOTE:
An external regulator is required to reduce supply pressure to a maximum of 10
1
/
2
" w.c. on Natural Gas
systems operating at higher pressure.
MILLIVOLT PRESSURE
Regulator Pressure Setting: 3.5" w.c.
Pilot Regulator: 3.5" w.c.
Gas Inlet Pressure: Max. 10 1/2" w. c. Min. 5" w.c.
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches.
Milli-Volt control has four (4) positions:
OFF
-
All gas to the burner is shut off at the valve.
IGN
-
Valve position to light/maintain a standing pilot.
ON
-
Valve position to turn burners ON/OFF with remote switch/thermostat.
LOW/HI
-
Variable position to control flame height (heat output). Both front and rear burners are in operation to
provide realistic glow and yellow flame.
PILOT/ODS
The gas log heater is fitted with a specially designed safety pilot (ODS assembly) light which senses the amount of oxygen
available in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot
can only be relit when adequate fresh air is available.
THERMAL GENERATOR
The millivolt gas log pilot is fitted with a millivolt thermopile generator to provide power for remote activation.
Gas Rate
Model Number
Type
Max. BTU/Hr Min. BTU/Hr
C2801/02/03/04VFN Milli-Volt
28,000
18,000
Gas Rate
Model Number
Type
Max. BTU/Hr Min. BTU/Hr
C2801/02/03/04VFP Milli-Volt
28,000
20,000
PROPANE / LPG
Note:
An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
MILLIVOLT PRESSURE
Regulator Pressure Setting: 10" w.c.
Gas Inlet Pressure: Maximum 13" w.c.
Minimum 11" w.c.