background image

September 2004  

P/N 61D0087 • Rev. 1

LIMITED WARRANTY 

FACTORY-BUILT FIREPLACE AND COMPONENTS

(EXCEPT BLOWERS)

WHAT IS COVERED AND FOR HOW LONG

• 

Five-Year Coverage:

 For five years from the date this fireplace and components are first purchased for use, Monessen Hearth 

Systems will, at its option, repair or replace any defective part of this fireplace or components, or refund to you a sum not to exceed 

the factory retail price in effect at the time of purchase.

•  

Ten-Year Coverage:

 From the sixth through the tenth year following the date this fireplace or accessory is first purchased for use, 

Monessen Hearth Systems will make available to you, at our factory, a free replacement for any defective part in this fireplace or 

accessory. 

•  

Twenty-Five-Year Availability of Replacement Parts: 

From the eleventh through the twenty-fifty year following the date this 

fireplace or accessory is first purchased for use, Monessen Hearth Systems will make available at our factory replacement parts for 

this fireplace or accessory, which you may purchase for the list price current at the time your purchase order is received. 

WHAT IS NOT COVERED

This limited warranty does not cover:
•  Transportation or shipping cost.
•  The cost of a service call to diagnose trouble.
•   Painted surfaces.
•   Damage or defect caused by improper installation, accident, misuse, abuse or alteration.
•   Poor ventilation of smoke or gases caused by air-conditioning and heating systems, exhaust fans, or pressure differentials produced 

by wind.

•   Broken glass components
•   Cracks in ceramic and castable parts that do not affect safe operation.
•   We do not warrant this fireplace to be in compliance with your local building code. Building codes vary greatly throughout the coun-

try, and you should determine whether your local building code contains restrictions on the use of this fireplace before you purchase 

it. 

•   Blowers or fans, which are warranted separately.
•   Heat loss due to the passage of heat or air through or around the fireplace.
Also, under our five year coverage, we do not pay the cost of removal and replacement of any portion of the structure in which the fire-

place is situated, made necessary by the repair, removal or re-installation of the fireplace.
And under our twenty-five year warranty of availability of replacement parts, we only promise to maintain a supply of replacement parts 

at our factory for you to purchase.

LIMITATIONS AND EXCLUSIONS

1.  No one has authority to add to or vary this limited warranty, or to create for Monessen Hearth Systems any other obligation of liability 

in connection with this fireplace and accessory. 

2.   Monessen Hearth Systems shall not be liable for incidental, consequential, special or contingent damages you might suffer as a result 

of its breach of this written warranty or any implied warranty. Some states do not allow the exclusion of limitation of incidental or 

consequential damages, so the above limitations may not apply to you.

3.  This warranty applies only to the original purchaser of the fireplace or to the original owner of the dwelling when the fireplace is 

installed in a new dwelling and may not be transferred.

5.   This warranty applies only to a fireplace sold and used in the United States.
For information about this warranty, contact:

 

Technical Services

 

Monessen Hearth Systems

 

149 Cleveland Drive

 

Paris, Kentucky 40361

Содержание BWBC400MHB

Страница 1: ...LACES U L FILE NO MH7603 These replaces have been tested to U L Safety Standard 127 and listed by Underwriters Laboratories Inc Look for the UL listing mark on your replace CONGRATULATIONS You have ch...

Страница 2: ...ace is listed by Underwriters Laboratories Inc to U L 127 Safety Standard For Factory Built Fireplaces The design of this replace and these instructions complied with the applicable U L 127 safety sta...

Страница 3: ...e these instructions for any future repairs Use these instructions as a guide during the installation of the replace Install all the parts used with this replace system in accordance with these instal...

Страница 4: ...connection The provision for a gas line is intended only for connecting one of the gas appliances gas log sets described by the following paragraph NOTICE Install only gas log sets which have been tes...

Страница 5: ...he individuals who will be operating them Instruction manuals must be left with operator of the system CAUTION While a gas log appliance is installed in one of these replaces solid fuels must not be b...

Страница 6: ...or restrict air circulation in any manner Blocking or restricting the air ow will cause the reboxtoreachhazardous temperatures WARNING Figure 2 Location of Cool Air Inlet and Warm Air Outlet Warm Air...

Страница 7: ...brick panel on the left side of the rebox as shown by Figure 5 NOTE Outside combustion air damper is open when its control lever is up The damper is closed when its control lever is down The replace m...

Страница 8: ...room that is centrally located in the house This will optimize heat circulation and comfort Locate replace away from frequently opened doors central heat outlets or returns or other places where air m...

Страница 9: ...n Securely support and level replace Check face of the replace with a carpenter s level If replace is not plumb correct it by placing shims under the edges of replace 2 Block in the replace to prevent...

Страница 10: ...sdiction The hearth extension must cover an area 16 400 unit or 20 500 unit in front of and 8 either side of the replace opening See Figures 8 and 9 If a raised hearth extension is desired the replace...

Страница 11: ...hat is 1 2 thick with a K value thermoconductivity of 0 43 or lower For example an insulating material 1 2 thick with a K value of 0 35 would be acceptable A hearth extension made from materials 1 2 t...

Страница 12: ...Models BWBC400MHB and BWBC500MHB replaces CLEARANCES Provide required clearances shown in Figures 10 through 12 Provide 2 minimum chimney air space clearance to combus tibles Figure 10 Minimum Cleara...

Страница 13: ...Extension Firestop Thimble Model SVTR Requires 141 2 x141 2 Opening Zero Clearance to Combustibles FIREPLACE INSTALLATION CLEARANCES CONTINUED Figure 12 Proper Clearances and Chimney Height You must...

Страница 14: ...minimum of 2 above all portions of the building within ten feet If the chimney is to include elbows to offset the chimney see Chimney Offset and Cap Installation Section There must be at least 2 air s...

Страница 15: ...he hole in the roof must be rectangular instead of square A 7 pitch requires 14 x14 framing A 15 pitch requires a 14 x15 framed opening 2 Install the SVTR restop thimble as shown in Figure 13 Nail it...

Страница 16: ...n of chimney and chimney cap or chimney housing to be removed for moving the manufactured home on the highway Note If additional strength of the outer pipe joints is desired place 2 or three 3 sheet m...

Страница 17: ...Installation Storm Collar 612 Flashing Roof Support Straps 4 Inclined portions of chimney are often used as stor age Enclose the inclined portions of chimney that pass through living spaces to avoid...

Страница 18: ...2 151 2 22 36 411 4 471 4 1 1 1 2 0 20 1 0 1 0 0 1 0 1 0 24 28 301 2 503 4 573 4 62 1 1 1 1 0 0 0 1 0 0 0 2 1 1 0 331 2 361 2 391 2 673 4 721 2 771 2 1 1 1 1 0 0 1 0 1 0 1 2 1 1 0 42 451 2 48 82 88 92...

Страница 19: ...un of the chimney to vertical 6 Nail the support straps of the second elbow to a building frame member 7 Continue installing the vertical portion of the chimney CHIMNEY CAP INSTALLATION MODEL SC CHIMN...

Страница 20: ...of the chimney cap sits on the chimney pipe Punch or drill 1 8 diameter holes in the inlet air duct chimney pipe where speci ed on the brackets Fasten chimney pipe down with the No 8 screws provided S...

Страница 21: ...in the structural integrity of the home Maintain the structural integrity of the manufactured home oor wall and ceiling roof CAUTION Figure 21 Attaching Outside Air Starting Collar and Insulation Ring...

Страница 22: ...way the ow of air through the air inlet and air outlet louvers in the face of the replace Seal any space between face of replace and non combustible facing material Failure to seal this crack is a po...

Страница 23: ...ith local codes or in the absence of local codes with the latest edition of National Electrical Code ANSI NFPA 70 See Figure 26 Always check and make sure power is off before attempting to install or...

Страница 24: ...ing is installed in the center of the top track This closure clip provides friction to the door guide pins which help hold the doors together properly 1 To remove a left or right glass door assem bly...

Страница 25: ...orner of the glass panel See Figure 28 5 Gently compress seat the glass spring retainers between the trim channels and glass Use chan nellock pliers to easily seat the glass spring retain ers Be caref...

Страница 26: ...pacer washers on the pivot pin as shown Note Normally washers will only be needed when a misalignment condition exists as a result of a combination of tolerances ranging from glass size variations rep...

Страница 27: ...ur yard Fireplace damper must be fully opened when using a gas appliance WARNING Do not burn plastics poison ivy twigs and stems and chemi cally treated woods such as discarded poles and railroad ties...

Страница 28: ...re your room is well ventilated your damper open and the ue is unobstructed Then make sure your wood is dry and seasoned Unseasoned wood burns poorly If you use unseasoned wood with poor ventilation o...

Страница 29: ...at produced by the replace Use the ON OFF rocker switch installed in the lower grille on the front of the replace to turn the fan on and off Prepare your re by placing two logs on the iron grate or re...

Страница 30: ...built to require very little maintenance The surfaces of the brass frames are coated with a clear baked on enamel to prevent tarnishing of the brass The brass nish is treated to withstand temperatures...

Страница 31: ...ainer Remove Hearth 4 Lift back edge of hearth upward using the two grate retainers Pull hearth toward you Remove hearth See Figure 33 Remove Side Brick Panels 5 Pull back edges of side brick panels t...

Страница 32: ...nmental conditions such as temperature and humidity or changes in the operation of the replace can lead to rapid buildup of soot and or creosote Have a a quali ed and reputable chimney sweep clean the...

Страница 33: ...ctions and proper chimney height when selecting the location and installing the chimney Don t store or place ammable liquids gases or pressur ized containers near the replace Don t put combustibles wi...

Страница 34: ...22 REPLACEMENT PARTS Failure to position the parts in accordance with these diagrams or failure to use only parts speci cally approved with this appliance may result in property damage or personal in...

Страница 35: ...D0619 9 Motor Assembly 2 077996 077996 10 Fan Base Bracket 2 029935 029935 11 Adjustable Spring Clip 2 037088 037088 12 Spring Door Closure 1 037416 037416 13 Glass Panel 4 61D0002 61D0004 14 Right Do...

Страница 36: ...tecting oor against sparks and radiant heat 5 FP6U 6 diameter x 8 long exible uninsulated combustion air duct Use with AK6 kit 6 603 6 duct connector for splicing FP6U ducts includes one connector and...

Страница 37: ...61D0087 37 NOTES...

Страница 38: ...38 61D0087 NOTES...

Страница 39: ...61D0087 39 ATTENTION APPLIANCE INSTALLER PLEASE RETURN THESE OPERATING AND INSTALLATION INSTRUCTIONS TO THE CONSUMER NOTES...

Страница 40: ...ect safe operation We do not warrant this replace to be in compliance with your local building code Building codes vary greatly throughout the coun try and you should determine whether your local buil...

Отзывы: