![MONDEX Klapi Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/mondex/klapi/klapi_installation-and-operating-instructions-manual_1826285007.webp)
7
Installation and Operating Instructions Klapi
type
on the sides
in the front
in the rear
upward
sauna size
Klapi 16
250
500
250
1250
8–16 m³
Table 4.3 Safety distances to inflammable material (mm) The safety distances are measured from the outer
surfaces of the product.
Safety distances
ceiling
(A)
The minimum safety distance from the top
surface of the heater to the ceiling is 1250 mm.
Masonry walls
(C)
Leave a 50 mm gap between the heater and the
wall. This requires that the front and one side of
the heater are unobstructed the air to circulate.
The space required for operation and main-
tenance (D). The user of the heater needs at least
1 m
2
of space in front of the heater.
Heater in a recessed wall
If the heater is installed in a recessed wall, leave
a 100 mm gap between the heater and the walls.
The space required for operation and
maintenance (D). The user of the heater needs at
least 1 m
2
of space in front of the heater.
Walls and benches made of inflammable
material
(B)
The minimum safety distances between the
heater and inflammable materials: 250 mm to
the sides and rear, 500 mm to the front.
The space required for operation and main-
tenance (D). The user of the heater needs at least
1 m
2
of space in front of the heater.
1250 mm
B
250
50
a
c
50
50
c
d
500
100
d
B
c
100
100
d
B
250
250
250
500
B