Monarch ROF700 Скачать руководство пользователя страница 4

Main Connection Points 

 

 

 
 

PLEASE READ THROUGH THIS GUIDE BEFORE COMMENCEMENT OF INSTALLATION. THIS UNIT HAS BEEN WET TESTED PRIOR TO 
DESPATCH AND SEALED. SEALS TO BE REMOVED AS PER DISCONNECTION OF A NORMAL SPEEDFIT CONNECTION. 

 
No 4

 (DRAIN) – Waste water to go to drain clamp connection via black ¼” tubing – supplied 

 
 

No 3

 (PERMEATE) – Pure water supply to appliance via grey 3/8” tubing – supplied 

 
 

No 1

(INLET)

 

 – Inlet mains water supply via grey 3/8” tubing – supplied  

It is recommended to have a soft water supply whenever possible to ensure maximum membrane life and performance. 
 

Optional Connections: 

Speedfit elbows are supplied to convert to connections as per the photograph. Simply remove same if straight connections 
required. 
On every speedfit connection used, chamfer edge of tubing to ensure internal ‘o’ ring in speedfit is not damaged. 
 

 

 
 
Mains Water Connection – isolating valve 

 

 

 

 
 
 
Procedure: 
1 – Remove the 2 screws holding the bracket together. 
2 – Turn the black knob till it's fully opened, you should be able to see a pointed pin retract. 
3 – Put the flat piece of the bracket behind the pipe where you want to locate this tap. 
4 – Bring the top half of the bracket over the piece that is behind the pipe now. 
5 – Replace the screws and tighten. 
6 – Now turn the black knob fully down (to close) and this should pierce the pipe. 
7 – Fix speedfit adaptor to female thread and tighten to seal. 
8 – Chamfer edge of 3/8” grey tubing and push into speedfit connection until tubing stops – approx. 1.5cm 
9 – When you next open the valve (the black handle) water will be available to the unit. 
 
Note: the isolating valve has an approved check valve for compliance with local water regulations. 
 
 
 
 
 
 

Содержание ROF700

Страница 1: ...High flow reverse osmosis water purifier with additional faucet Monarch ROF700 Installation Manual Effective June 2014...

Страница 2: ......

Страница 3: ......

Страница 4: ...speedfit connection used chamfer edge of tubing to ensure internal o ring in speedfit is not damaged Mains Water Connection isolating valve Procedure 1 Remove the 2 screws holding the bracket togethe...

Страница 5: ...ed Accompanying the unit will be a selection of speedfit connections suitable for and male threads for POU All of them terminate at 3 8 speedfit to suit the grey flexible tubing with the unit Simply m...

Страница 6: ...over off The rear section can then be removed by undoing the 4no recessed and 1no surface mounted brass screw behind left hand membrane in the dark grey plastic main body Remove the membrane from its...

Страница 7: ...this will give salty water to service E After 30 minutes turn off power Connect 3 8 grey tube currently over sink to appliance F Turn power back on and wait until pump turns off The pump turning off...

Страница 8: ...nufacturer of your unit includes 50 years of manufacturing experience to give you a water purifier that is arguably the most reliable on the market today One of the aspects incorporated into the manuf...

Страница 9: ...service 1 Ensure power supply is on 2 Ensure water supply is on 3 Ensure there is no water leakage 1 Leakage on booster pump Water running inside unit 1 Call Monarch Water 2 Booster pump runs normally...

Страница 10: ...te work carried out Date work carried out Date work carried out Date work carried out Date work carried out Date work carried out Date work carried out Date work carried out Date work carried out Date...

Отзывы: