Main Connection Points
PLEASE READ THROUGH THIS GUIDE BEFORE COMMENCEMENT OF INSTALLATION. THIS UNIT HAS BEEN WET TESTED PRIOR TO
DESPATCH AND SEALED. SEALS TO BE REMOVED AS PER DISCONNECTION OF A NORMAL SPEEDFIT CONNECTION.
No 4
(DRAIN) – Waste water to go to drain clamp connection via black ¼” tubing – supplied
No 3
(PERMEATE) – Pure water supply to appliance via grey 3/8” tubing – supplied
No 1
(INLET)
– Inlet mains water supply via grey 3/8” tubing – supplied
It is recommended to have a soft water supply whenever possible to ensure maximum membrane life and performance.
Optional Connections:
Speedfit elbows are supplied to convert to connections as per the photograph. Simply remove same if straight connections
required.
On every speedfit connection used, chamfer edge of tubing to ensure internal ‘o’ ring in speedfit is not damaged.
Mains Water Connection – isolating valve
Procedure:
1 – Remove the 2 screws holding the bracket together.
2 – Turn the black knob till it's fully opened, you should be able to see a pointed pin retract.
3 – Put the flat piece of the bracket behind the pipe where you want to locate this tap.
4 – Bring the top half of the bracket over the piece that is behind the pipe now.
5 – Replace the screws and tighten.
6 – Now turn the black knob fully down (to close) and this should pierce the pipe.
7 – Fix speedfit adaptor to female thread and tighten to seal.
8 – Chamfer edge of 3/8” grey tubing and push into speedfit connection until tubing stops – approx. 1.5cm
9 – When you next open the valve (the black handle) water will be available to the unit.
Note: the isolating valve has an approved check valve for compliance with local water regulations.