background image

Below is a list of the menu items:

D E C P T

D E C P T

D E C P T

D E C P T

D E C P T

- Decimal Point (none, 1 or 2)

B L I T E

B L I T E

B L I T E

B L I T E

B L I T E

- Backlight (Yes=On or No=Off)

I N P U T

I N P U T

I N P U T

I N P U T

I N P U T

- Positive (pos) or Negative (neg) Edge for Input Signal

O U T P T

O U T P T

O U T P T

O U T P T

O U T P T

- Positive (pos) or Negative (neg) Edge for Output Signal

B L A N K

B L A N K

B L A N K

B L A N K

B L A N K

- Input Blanking (Yes=On or No=Off)

4.0 OPERATION

To turn on the stroboscope, depress and hold the trigger. The trigger may be
locked in position using the side locking button. To lock the stroboscope
on, depress the trigger as far as it will go and then press the locking button.
Once the locking button is set you may release the trigger and the trigger will
be held in place. To unlock the stroboscope, simply depress the trigger and
then release.

There are five operating modes for the 

Phaser-Strobe pbx

.  These are Internal,

External Input, External Phase Delay, External Time Delay, and Auto (Virtual
RPM).  All but the Internal Mode require an 

external input signal

.

In the 

Internal Mode

 the knob adjusts the flash rate.  In the 

External

Input Mode

 an external signal is used to trigger the flash and the knob has

no effect.  The 

External Delay Modes (Phase, Time and Auto)

 enable the

user to vary the stopped motion image at any point in the cycle without
having to move the trigger source location.

4.1

Internal Mode - Standard Strobe Operation

In the 

Internal Mode

 the stroboscope generates it’s own signals and

functions like a tunable stroboscope.  The strobe is in the Internal
Mode when nothing is plugged into the input jack or when manually
set using the 

INPUT

 button.

6

15

The stroboscope is designed to discharge the internal high voltages
within 30 seconds. However, caution should be exercised when replacing
the lamp.

The lamp can be replaced by using just a pocket screwdriver.  

It is not

necessary to remove any screws to replace the lamp.

To change the lamp:

1.

Push apart the two tabs on the side of the reflector housing and
remove the lens using a small screwdriver to help pry one tab and
lift the lens. Take care not to pry the tab any more than is necessary
to free the lens. The reflector is held in place by the front lens and
will come loose, but it is not necessary to remove the reflector.

2.

Hold the lamp with a cloth between your forefinger and thumb
and rock it back and forth gently while pulling out. Do not attempt
to rotate the lamp. The lamp is socketed and will come out easily
when pulled straight out.

WARNING:

Do NOT touch the new lamp with bare fingers.

3.

The lamps are polarized and must be put into the socket matching
polarity. 

Using a lint free cloth, match up the red dot on the

plug with the red dot on the socket

 and gently rock the lamp

while pushing it into place (see Figure 4). Make sure the lamp is
in straight and centered in the reflector hole.

CAUTION:

Do NOT allow the reflector to contact the lamp.

Содержание Phaser Strobe PBX

Страница 1: ...Strobe pbx Portable Phase Shifting Stroboscope MONARCH INSTRUMENT Instruction Manual Printed in the U S A Copyright 2008 Monarch Instrument all rights reserved 1071 4210 112R 1009 www 64817 com www 64...

Страница 2: ...serious damage to the equipment or severe personal injury or death may occur as a result 8 This instrument may not be safe for use in certain hazardous environments and serious personal injury or deat...

Страница 3: ...or details Monarch Instrument s Limited Warranty applies See www monarchinstrument com for details Warranty Registration and Extended Warranty coverage available online at www monarchinstrument com 10...

Страница 4: ...power down is remembered and restored on next power up 9 user settable flash rates Output Pulse 40 sec positive negative pulse menu selectable 3 3 Vdc typical Input Power Internal Rechargeable Batteri...

Страница 5: ...NS Internal Mode Flash Range 30 50 000 FPM Flashes Per Minute Flash Rate Accuracy 0 004 of setting or last digit Flash Rate Resolution 0 01 to 1 FPM menu selectable 0 1 FPM max resolution above 9 999...

Страница 6: ...hase Time and Auto VRPM 19 8 3 External Power Supply Charger The external power supply charger PSC pbxU can also be used to run the stroboscope continuously from the AC mains 115 230 Vac To power the...

Страница 7: ...ccept 1 8 3 5mm phone plugs input stereo output mono The input and output are TTL compatible See Figures 2 and 3 for connector connection detail 18 by no flash and the display shows LO BAT At this tim...

Страница 8: ...se batteries contain fewer toxic metals than NiCd Nickel Cadmium and are currently classified environmentally friendly They also have 30 more capacity than NiCd batteries of the same size Like NiCds N...

Страница 9: ...then the MENU button 2 SETUP and the menu option will be displayed 3 Turn the tuning knob to cycle through the main menu options 4 Once the desired menu option is displayed press the MENU button to s...

Страница 10: ...ource location 4 1 Internal Mode Standard Strobe Operation In the Internal Mode the stroboscope generates it s own signals and functions like a tunable stroboscope The strobe is in the Internal Mode w...

Страница 11: ...up to the maximum flash rate This is very helpful on fan blades Using this feature one can superimpose the blades on top of each other and check for blade tracking bent blades lead and lag tests etc 1...

Страница 12: ...played 13 Example Object Rotating at 5000 RPM If the speed is outside the full scale range of the stroboscope 50 000 FPM it can be measured using the method of harmonics and multipoint calculation Sta...

Страница 13: ...ed to be considered First the object being measured should be visible for all 360 of rotation e g The end of a shaft Second the object should have some unique part on it like a bolt key way or imperfe...

Страница 14: ...y Modes Phase Delay Time Delay and Auto Virtual RPM In the External Phase Delay Mode the flash is triggered 0 1 to 359 9 degrees after each external signal pulse The knob sets the amount of delay in d...