Содержание Nova-Pro UV365

Страница 1: ...nd UV385 LED Stroboscopes Laser Tachometers 15 Columbia Drive Amherst NH 03031 USA Phone 603 883 3390 Fax 603 886 3300 E mail support monarchinstrument com Website www monarchinstrument com Instructio...

Страница 2: ...s environments and serious personal injury or death could occur as a result of improper use Please refer to your facility s safety program for proper precau ons 8 Do not clean this instrument with alc...

Страница 3: ...This is not a toy Always supervise children Monarch Instrument s Limited Warranty applies See www monarchinstrument com for details Warranty Registration and Extended Warranty coverage available onli...

Страница 4: ...e 12 5 MENU SETTINGS 13 14 5 1 Menu Overview 15 5 2 MODE Menu 15 5 3 Brightness BRITE Menu 16 5 3 1 Degrees 16 5 3 2 Time 17 5 4 Miscellaneous MISC Menu 17 5 4 1 DECPT Decimal Point Menu 17 5 4 2 UNIT...

Страница 5: ...Delay 26 7 2 External Laser Delay 27 7 2 1 Phase Delay 27 7 2 2 Time Delay 28 7 2 3 AUTO Virtual RPM 28 8 BATTERY PACK 29 8 1 Low Ba ery Func onality 30 8 2 Charging the Ba ery Pack 30 9 AC POWER OPT...

Страница 6: ...ome standard as ba ery powered and have delay func ons which enable the user to delay the ash by degrees or me and do virtual slow mo on inspec on of rota ng and reciproca ng objects Both models have...

Страница 7: ...te the unit when power is on 5 Tripod Mount 1 4 20 tripod mount for hands free opera on 6 Power Source Ba ery Pack Removable ba ery pack Recharged in the external ba ery Charger Base OR AC Power Plug...

Страница 8: ...e consists of a large backlit display with touch keypad dedicated keys on the user interface panel and a trigger to ac vate the unit when the power is on The user interface is described in Figure 2 an...

Страница 9: ...elected 9 x2 2 and arrows Used to double or halve the ash rate 10 POWER button Turns the unit on and off Also used as escape back button in menus and locks the strobe on when pushed with the trigger e...

Страница 10: ...opera on in most countries See sec on 10 With the power source battery or AC inserted into the Nova Pro turn the unit on by pressing and holding the POWER button until the display illuminates then re...

Страница 11: ...power an external sensor and will accept a signal from 3 to 12 volts The output is TTL compa ble 3V and provides a pulse synchronized to the internal generator ash rate or external input signal Conne...

Страница 12: ...he user The strobe will not ash un l the trigger is depressed The strobe will output a pulse from the output jack at the rate of the internal se ng whether the trigger is pressed or not The user can s...

Страница 13: ...nd show the units you are entering Note that this is a capaci ve touch sensi ve keypad and will not respond if the user is wearing gloves 4 1 3 Doubling or Halving the Flash Rate Press the MENU bu on...

Страница 14: ...ource becomes the source of trigger for the ash The user cannot make any ash rate adjustments and the display will show the rate of the external input External icon will show in display when there is...

Страница 15: ...t source the Nova Pro UV365 UV385 has a Lamp Mode that creates a bright constant light for inspec on Be aware that this mode uses considerably more ba ery power and that you should never look directly...

Страница 16: ...he laser at a re ec ve target on the rota ng or reciproca ng machine the strobe will ash each me a re ec on is received allowing the user to virtually stop mo on On Target icon will show in display wh...

Страница 17: ...de is enabled and be on solid when trigger is pulled and laser is on External icon will show in display when there is an external sensor plugged into the Nova Pro Pull the trigger and aim the laser or...

Страница 18: ...the Laser Module is installed TACHometer MODE SEtUP MODE MISC RPM to SET Power button 2X to TACH RPM BKLIT ON OFF OUTP to SET to SET POS nEG SEr UNITS RPM DECPT to SET none 1 2 3 RPS FPM FPS Nova Pro...

Страница 19: ...LAMP RPM NONE PHASE TIME MEMRY Recall M1 2 3 10 to SET to SET to SET to SET MISC DECPT none 1 2 3 Power button 2X to STROBE RPM BRITE input number input number input number input number DEGS TIME Sav...

Страница 20: ...bu on to enter menu op ons and make selec ons Press the POWER bu on to escape or back out of the menus On Target icon will show which menu op on is selected The following sec ons describe the individu...

Страница 21: ...f you adjusted degrees the strobe will have a ash dura on in degrees propor onal to the ash rate If the adjustment was in me the strobe will have a xed dura on irrespec ve of the ash rate This is a li...

Страница 22: ...MENU button to enter the MISC menu Use the and arrows on the joys ck to scroll through the miscellaneous op ons Press the MENU bu on to select the desired op on Press the POWER bu on to exit escape 5...

Страница 23: ...ts the Engineering Units used to display the ash rate or speed The choices are FPM Flashes per Minute Not available in TACH Mode FPS Flashes per Second same as Hz not available in TACH Mode RPM Revolu...

Страница 24: ...r bu on to save the value To exit without changing the polarity press the Power bu on 5 4 4 OUTP OUTPUT Menu This menu sets the pulse polarity of the output signal that will trigger a device connected...

Страница 25: ...The se ngs that are saved and recalled are the ash rate and the brightness All other se ngs on the unit remain the same Press the MENU button to enter the MEMRY menu Use the right arrow on the joys c...

Страница 26: ...recall the se ng from the selected loca on To exit without recalling a memory loca on press the Power bu on 5 6 JOG Menu This menu op on is only valid in the STROBE Mode with NO External Input Refer t...

Страница 27: ...ess the MENU bu on when TIME is displayed The me value will be shown in milliseconds Use the joys ck to set the desired value refer to sec on 5 1 1 Time can be set from 50 000 mSec to 50 000 mSec Pres...

Страница 28: ...To Delay by PHASE press the MENU bu on when PHASE is displayed This method of delay is set the same as PHASE in JOG NOTE The adjustments happen in real me so if the strobe is ashing the user can view...

Страница 29: ...rsistence of the human eye the ability to remember and image and its response to bright light to give an apparent stop motion image Imagine a shaft rotating at 6000 RPM or one rotation every 1 100 of...

Страница 30: ...ence between a 1 and 5 of rota on ash dura on There are two methods of adjus ng the ash pulse width and hence the brightness and consequently the blur For se ng Brightness see Brightness BRITE Menu 6...

Страница 31: ...idth of 3 8 msec The strobe will limit this value to 2 0 msec or 7 3 of rota on blur 7 STROBE DELAY The Nova Pro UV has mul ple special e ects that can be used to inspect moving machinery in di erent...

Страница 32: ...Figure 8 Phase Shi1ing by 30 60 90 7 2 External Laser Delay There are three External Delay Modes Phase Delay Time Delay and Auto Virtual RPM These modes are only ac ve if an external trigger source i...

Страница 33: ...nu 50 000 to 50 000 msec The TIME Delay is absolute and remains constant irrespec ve of the speed of the target The display will show the TIME icon to indicate the Delay Mode The e ect is similar to F...

Страница 34: ...When ordered as such the Nova Pro UV comes with one or two rechargeable Lithium Ion ba ery pack s external charger and power supply The Ba ery Pack is shipped in a mostly discharged state and has tap...

Страница 35: ...ery Pack must be removed from the Nova Pro to be charged using the Nova Pro Charging Sta on and power supply provided CAUTION Never a empt to charge the Ba ery Pack with anything other than the Chargi...

Страница 36: ...ALL POWER SUPPLIES The wall power supplies provided with the Nova Pro UV have interchangeable plugs allowing them to be used with AC outlets in di erent countries To change the plugs depress the bu on...

Страница 37: ...vides 3 3 Vdc TTL output Tachometer Mode 0 999 999 RPM with integral laser or external input Programmable Memory Yes 10 set points Internal Phase Shi Yes Phase Delay degrees 360 0 to 345 0 degrees Tim...

Страница 38: ...s of UN DOT 38 3 Tested by Shenzhen SEM Test Technology Co Ltd Reports STR16079052S 54S 11 2 2 EU Declara on of Conformity Please visit our website www monarchinstrument com to download our EU Declara...

Страница 39: ...tereo phone plugs to provide TTL signal and sensor power CA 4044 6 6 foot 1 8 m Input Output cable 1 8 inch 3 5 mm male phone plug to male BNC connector CA 4045 6 6 foot 1 8 m Input Output cable 1 8 i...

Страница 40: ...Machine Vision Stroboscopes Check out our other product lines Speed Sensors Temperature Humidity Sensors Vibra on Meters Paperless Recorders Track It Data Loggers Printed in the U S A Copyright 2017 2...

Отзывы: