the sliding switch (2) must be set to MAG. PHONO or AUX. For cas-
setteV/audio tape operation use the AUX input, cinch jack PB (14).

Operation

1) At first set the controls (1+ 4) to “0” position.

2) Connect the mains plug to the mains supply (230 V~/50 Hz). After

switching on the operating LED ON (8) is lighting.

3) Set the input controls (1) as well as the tone controls (3) to the desired

values.
Adjust the overall volume with the MASTER control (4). The VU meter
(5) displays the output level.

Microphone Priority Circuit

With the microphone channel 1 an actual music programme (in the AUX/
PHONO channel 4) can be talked over for announcements etc. while the
music is automatically attenuated down to 20 dB. There is a soft fading in
and out.

With counterclockwise position of the FADER control (16) at the rear this

function does not work. With turning this control clockwise to the end stop
the max. music attenuation is adjusted.

Battery Operation

The 24 V battery connections (11) are at the amplifier rear. If the 24 V volt-
age is connected, the amplifier is in operation immediately. The LED ON
(8) is lighting. The power switch (7) is out of function.

If 230 V alternating voltage and 24 V direct voltage are connected at the

same time, then the amplifier operates with mains. In case of mains failure
it automatically switches over to battery operation.

Circuit breaker

In case of short-circuit or overload a circuit breaker (9) automatically opens
the circuit, the LED PROTECT (6) is lighting. After removal of the error this
switch (9) can be closed again.

Specifications

Output power: . . . . . . . . . . . . . 100 W max.
THD:  . . . . . . . . . . . . . . . . . . . 2 %/60 W
Outputs

Speakers:  . . . . . . . . . . . . . . 4/8/16

, 70/100 V

Preamplifier (jack REC):  . . . 200 mV (20-20 000 Hz, ±1 dB)
Line Out  . . . . . . . . . . . . . . . 1 V/600

Inputs

MIC/LINE 1-3: . . . . . . . . . . MIC 0.5 mV/3 k

(for low imped. mikes)

switchable to line level 120 mV/220 k

MIC 4/AUX/PHONO:  . . . . . MIC 0.5 mV/3 k

(for low impedance

microphone) switchable to
MAG. PHONO 3 mV/47 k

(RIAA) or

AUX 200 mV/250 k

Frequency Range:  . . . . . . . . . 50-15 000 Hz, ±3 dB
Tone controls

Bass:  . . . . . . . . . . . . . . . . . ±10 dB/100 Hz
Treble:  . . . . . . . . . . . . . . . . ±10 dB/10 kHz

S/N ratio:  . . . . . . . . . . . . . . . . > 60 dB
VU meter: . . . . . . . . . . . . . . . . 0 dB at 60 W
Power supply: . . . . . . . . . . . . . 230 V~/50 Hz, 24 V

ext., approx. 6 A

Dimensions (W x H x D):  . . . . . 385 x 125 x 280 mm
Weight: . . . . . . . . . . . . . . . . . . 10.8 kg
According to the manufacturer. Subject to technical change.

Subject to technical change.  Copyright © by INTER-MERCADOR GMBH & CO. KG, Bremen, Germany.  All rights reserved. 09.95.02

PA-802

Best.-Nr. 17.0120

0

2

4

6

8

10

0

2

4

6

8

10

0

2

4

6

8

10

MIC 1/LINE 1

MIC 2/LINE 2

MIC 4

AUX/PHONO

BASS

MASTER

PROTECT

POWER

ON

+6 dB

+3 dB

+0 dB

-3 dB

-6 dB

-10 dB

-20 dB

+8

6

4

2

0

2

4

6

-8

MIC 4

AUX

MAG PHONO

PA-802

8

6

4

2

0

TREBLE

0

2

4

6

8

10

MIC 3/LINE 3

OUTPUT

LEVEL

PA AMPLIFIER

®

1

2

3

4

5

6 7

8

GB Operating Instructions

PA Amplifier PA-802

A very efficient mono PA amplifier in professional quality for 230 V~/50 Hz and
24 V DC operation. Due to the silicon technique the complete amplifier is
insensitive to temperature changes. Extensive protection circuits are installed.

Safety Notes

This unit uses lethally high voltage (230 V~). To prevent a shock hazard
do not open the cabinet. Leave servicing to authorized skilled personnel
only. Besides any guarantee claim expires if the unit has been opened.

For the operation also watch in any case the following items:

The unit is only suitable for indoor use.

Avoid excessively warm locations for the unit or high humidity.

Do not set the unit into operation and immediately take the mains plug
out of the mains socket if:
1. damage at the unit or mains cable can be seen.
2. a defect might have occurred after a drop or similar accident.
3. there are malfunctions.
The unit must in any case be repaired by authorized skilled personnel.

Never pull the mains plug out of the mains socket by means of the mains
cable.

If the unit is used for purposes other than originally intended, if it is oper-
ated in the wrong way or not repaired by authorized skilled personnel,
there is no liability for possible damage.

For the cleaning only use a dry cloth for dust removing, by no means
chemicals or water.

Important for U. K. Customers!
The wires in this mains lead are coloured in accordance with the follow-
ing code:
green/yellow = earth
blue = neutral
brown = live
As the colours of the wires in the mains lead of this appliance may not
correspond with the coloured markings identifying the terminals in your
plug, proceed as follows:
1. The wire which is coloured green and yellow must be connected to
the terminal in the plug which is marked with the letter or by the earth
symbol 

, or coloured green or green and yellow.

2. The wire which is coloured blue  must be connected to the terminal
which is marked with the letter or coloured black.
3. The wire which is coloured brown must be connected to the terminal
which is marked with the letter or coloured red.

Warning - This appliance must be earthed.

Output Connections

There are terminals (10) for 4,8,and 16

impedance.

On a separate terminal strip (12) there are connections for 70 V and

100 V with the facility to use them without ground or chassis connection.

Pramplifier and Line Outputs

These outputs are provided as cinch jacks REC (15) and 

1

/

4

” jack LINE

OUT (17) at the amplifier rear.

Input Connections

The input jacks (13, 18, 19, 21) are connected as desired. Set the selec-
tor switches MIC/LINE (20) for the inputs MIC/LINE 1-3 (21) to the cor-
responding positions. If a turntable with magnetic system is connected to
the 

1

/

4

” jack MAG. PHONO (19) or a source to the auxiliary input AUX (13),

230V~  50 Hz

0,8 A T

CIRCUIT BREAKER

5 A

GND

COM

16 

24 V DC

COM

70 V

100 V

MIC
LINE

1

MIC
LINE

2

MIC
LINE

3

MIC 4

AUX

MAG.

PHONO

LINE
OUT

REC

PB

FADER

MIN

MAX

9

10

11

12

13 14 15 16 17 18 19 20

21

Отзывы: