background image

ELECTRONICS FOR SPECIALISTS    ELECTRONICS FOR SPECIALISTS    ELECTRONICS FOR SPECIALISTS    ELECTRONICS FOR SPECIALISTS

MONACOR INTERNATIONAL GmbH & Co. KG  •  Zum Falsch 36  •  28307 Bremen  •  Germany 

Copyright 

©

 by MONACOR INTERNATIONAL.  All rights reserved. 

A-2098.99.01.04.2021

EDL- 6

Order No. 1000263

4  Electrical Connection

WARNING

During operation, there is a hazard 
of contact with a dangerous voltage 
of up to 100 V at the speaker cable. 
Installation must always be carried 
out by skilled personnel.

Observe the load of the speakers on the PA am-
plifier. Overload may damage the amplifier! The 
total power of all speakers connected must not 
exceed the amplifier power.

1)  If the PA system is switched on, switch it off 

completely before connecting it!

2)  Connect the speaker via the screw terminals 

(black core = negative pole).

3)  When connecting several speakers, make sure 

that all speakers have the same polarity and 
that the PA amplifier is not overloaded.

5  Specifications

Power rating: . . . . . . . .  8 W
Frequency range:  . . . . .  90 – 18 000 Hz
Sensitivity: . . . . . . . . . . .  90 dB  (1 W/1 m)
Max. rated SPL: . . . . . . .  99 dB
Radiation angle: . . . . . .  90°
Voice coil: . . . . . . . . . . . 

 20 mm

Ambient temperature:  .  0 – 40 °C
Outside diameter: . . . . .  193 mm
Mounting cutout: . . . . . 

 170 mm

Mounting depth:  . . . . .  65 mm
Total depth:  . . . . . . . . .  72 mm
Weight:  . . . . . . . . . . . .  492 g

Subject to technical modification.

PA Ceiling Speaker

These instructions are intended for installers 
with sufficient knowledge of 100 V technol-
ogy for PA applications. Please read the in-
structions carefully prior to installation and 
keep them for later reference.

1  Applications

This speaker is specially designed for applications 
in PA systems. It is equipped with a transformer for 
operation in 100 V systems.

2  Safety Notes

The speaker corresponds to all relevant directives 
of the EU and is therefore marked with  .

• 

The speaker is suitable for indoor use only. Pro-
tect it against dripping water, splash water and 
high air  humidity. The admissible ambient tem-
perature  range  is  0 – 40 °C.

• 

For cleaning only use a dry, soft cloth; never use 
water or chemicals.

• 

No guarantee claims for the speaker and no lia-
bility for any resulting personal damage or ma-
terial damage will be accepted if the speaker is 
used for other purposes than originally intended, 
if it is not correctly installed or connected, or if 
it is overloaded.

If the speaker is to be put out of opera-
tion definitively, dispose of the speaker in 
accordance with local regulations.

3  Mounting

1)  Saw a hole of the corresponding size into the 

ceiling (

 170 mm).

2)  Make the electrical connection (chapter 4).
3)  Fold the two clamps upwards.
4)  Insert the speaker into the ceiling cutout until 

the clamps are folded down and the speaker is 
clamped on the ceiling.

English

Отзывы: