Momento UCG Скачать руководство пользователя страница 3

© 2011 OJ Electronics A/S

3

© 2011 OJ Electronics A/S

Type UCG/UDG  

 English

10

  Press the 

Up

 or 

Down

 buttons to set the required temperature.

11

  Press the 

OK

 button. The symbol for the next event (e.g. at 

work) will now flash, allowing you to set the time and tempera-
ture for this period of the day by repeating steps 6-12.

12

  Once time and temperature have been set for the four events 

applicable for the 5-day period Monday to Friday, 

Exit

 will flash.

13

  Press the 

OK

 button. The next 2 days, 

Sat Sun

, will then flash. 

Please note that now only two events (Day and Night) are dis-
played. 

14

  Press the 

OK

 button. The symbol for the first event will flash.

15

  Set the time and temperature for this event, and for the following 

event, by repeating steps 6-12.

16

  Finally, select 

Exit

 to exit the 

Program

 for a 5:2 schedule.

PROGRAM

SAT SUN

EXIT

SET TEMP

Quick Set Temperature 

I want to permanently change the temperature for 

the event currently active in the automatic program.

To do so, you must:

1

  Press the 

Up

 or 

Down

 buttons to set the required temperature 

for the event currently active.

2  

Press the 

OK

 button.

The new temperature setting will then be saved and used for this 
event in the future. 

Example: If you change the temperature on a Tuesday morning 
while the thermostat is running a 5:2 program, the new tempera-
ture will apply to all mornings from Monday to Friday.

Adaptive Function

I want to ensure that the required temperature has 

already been reached when I get up in the morning 

or come home from work.

To do so, you must activate the adaptive function: 

1

  Press the 

OK

 button to activate the menu.

2

  Press the 

Up

 or 

Down

 buttons until the 

Settings

 option flashes.

3

  Press the 

OK

 button.

4

  Press the 

Up

 or 

Down

 buttons until the 

Adaptive

 option flashes.

5

  Press the 

OK

 button. On or Off will now flash in the upper part 

of the display.

6

  Press the 

Up

 or 

Down

 buttons until 

On

 flashes.

7

  Press the 

OK

 button.

8

  Select 

Exit

 to exit the option.

Please note:

 The adaptive function is only related to the 4-event 

program and only works in connection with going from one event to 
another where the temperature is going to be raised. 

The adaptive function calculates when the thermostat must start 
the heating system to ensure that the required temperature is 
reached at the set time. Three days after the adaptive function has 

been activated, it has learned when the heating must be switched 
on to attain the required temperature.

Factory setting: ON

SETTINGS

TIME
DAY
CHILDLOCK
C°/F°
APPLICATION
OFFSET TEMP
READOUT
ADAPTIVE
DISPLAY
FACTORY RESET
EXIT

Manual Mode

I want to temporarily cancel the automatic 4-event 

program and manually select temperature.

To do so, you must use manual mode:

1

 Press the 

OK

 button to activate the menu.

Press the 

Up

 or 

Down

 buttons until the 

Mode

 option flashes.

3

 Press the 

OK

 button.

4

  Press the 

Up

 or 

Down

 buttons until 

Man. mode

 flashes in the 

upper part of the display. The temperature will begin to flash. 

5

  Press the 

Up

 or 

Down

 buttons until the required temperature 

flashes.

6

  Press the 

OK

 button.

Please note: 

This feature can be useful for instance if you are go-

ing on holiday and want to maintain a frost protection temperature 
(e.g. 41°F) while you are away.

To return to the automatic 4-event program, you must select Auto. 
Please refer to page 2 for instructions.

MAN. MODE

MODE

Temporary Override

I want to temporarily set a comfort temperature for 

a single event, e.g. because I am not at work one 

day and want to maintain a higher temperature or 

because I am having a party.

To do so, must use override mode:

1

  Press the 

OK

 button twice to activate the menu.

2

  Press the 

Up

 or 

Down

 buttons until the 

Mode

 option flashes.

3

  Press the 

OK

 button.

4

  Press the 

Up

 or 

Down

 buttons until 

Override

 flashes in the up-

per part of the display. The temperature will begin to flash. 

5  

Press the 

Up

 or 

Down

 buttons until the required temperature 

flashes.

6  

Press the 

OK

 button.

Please note: 

Override mode is a temporary temperature setting 

that is cancelled automatically by the next event in the scheduled 
4-event program.

Содержание UCG

Страница 1: ... the required time After three days the adaptive function has learned when the heating must be switched on First Time Settings The first time you turn on the thermostat time and day must be set The time flashes Set the current time using the Up or Down buttons Then press the OK button to confirm the time The day of the week will then flash Select the current day using the Up and Down buttons Press...

Страница 2: ...rt of the display 5 Press the OK button Factory setting Auto mode AUTO OVERRIDE MAN MODE MODE SCHEDULE PROGRAM SETTINGS EXIT Step 2 Choosing the weekly schedule for your program You have the following options 5 2 will give you 5 days Monday to Friday with the same four events Morning Out Home Night and 2 days Saturday and Sunday with the same two events Morning and Night 6 1 will give you 6 days M...

Страница 3: ... option Please note The adaptive function is only related to the 4 event program and only works in connection with going from one event to another where the temperature is going to be raised The adaptive function calculates when the thermostat must start the heating system to ensure that the required temperature is reached at the set time Three days after the adaptive function has been activated i...

Страница 4: ...shes 6 Press the OK button 7 Select Exit to exit the option Please note Temperatures are displayed in Celsius with a resolu tion of 0 5 degree and in Fahrenheit with a resolution of 1 degree Factory setting Celsius SETTINGS C F Setting Time I want to change the time To do so you must 1 Press the OK button twice to activate the menu 2 Press the Up or Down buttons until the Settings option flashes 3...

Страница 5: ...at and a room thermometer It is possible to adjust the offset by up to 10 C or 18 F Once the offset has been set correctly the thermostat will display the same temperature as the thermometer If for example the thermostat shows 1 too much the offset should be set to 1 The temperature will then be set 1 lower SETTINGS OFFSET TEMP Application I want to select the type of temperature control To do so ...

Страница 6: ... option flashes 7 Press the OK button 8 Select Exit to exit the option SETTINGS TIME DAY CHILDLOCK C F APPLICATION OFFSET TEMP READOUT ADAPTIVE DISPLAY FACTORY RESET EXIT RESET EXIT Exit Menu I want to exit a menu To do so you must use the Exit option The various menus and submenus contain an Exit option 1 Press the Up or Down buttons until Exit flashes 2 Press the OK button You may have to repeat...

Отзывы: