2. Installation
2.1 Preparation
- Check the membrane of visual transport damage.
- Read and follow the safety instructions and the operating
instructions, before handling with the device !
2.2 Mounting in the vessel
Position the level indicator at the flange and fix it with 4 washers and
screws M5.
2.3 Electrical connection
Circuit diagram
2.4 Cable gland
Screw on the cap nut until the cable gland is closed tightly.
-
3. Commissioning
Put the level indicator into operation only, if the installation and the
electrical connection have been done correctly.
-
4. Setting of the sensitivity
- The level indicator is preset at sensitive.
- With the adjusting screw the device can be set less sensitive.
- Remove the safety screw from the housing cover.
- Pull off the cover from the lower part of housing.
- Set the sensitivity of the switch according to your needs with the
adjusting screw. Clockwise insensitive.
- Put on the housing cover and fasten it with the screw.
M LLET
Füllstandtechnik
GmbH
02
MFA-BA 04/13
©
by MOLLET
Operating instructions MOLLET D-74706 Osterburken Tel. +49 6291 6440-0 Fax +49 6291 9846
5.
5.1
- Use the level indicator in its intended application only.
- The level indicator is provided for use in silos or vessels with
pressureless operation.
- Comply with the
on the data plate. Check the
membrane of the level indicator, when the permissible temperature
of bulk goods was exceeded or was fallen short off.
- Damaged devices have to put out of operation immediately.
5.2 Inexpert handling
-
of the safety instructions and the operating instructions.
- Not intended use.
- Violation against applicable law and standards.
-
6. Maintenance
- Do maintenance work only, if the silo or the vessel is empty and
if there is no overpressure or vacuum.
- Inspect in regular intervals if there is any wear or abrasion at the
membrane. Define the control intervals, depending on the
characteristics of the bulk goods.
- Replace the device in case of damage or abrasion of the
membrane.
-
7. Storage
- Store the level indicator dry and dust-free.
- Protect the membrane against pointed objects and ultraviolet
radiation.
-
8. Disposal
- The level indicator can be recycled.
- The disposal applies to the valid environmental guidelines
according to the location of the carrier and the local manufacturing
conditions.
Utilization
Normal operation
Ignoring
specifications
NC NO
C
P
2 3/4 1
1
adjusting screw with locking nut
2
3/4
002-AP00
Membrane level indicator
MFA