Mollet MOLOS membran MFA Series Скачать руководство пользователя страница 1

Operating instructions

1. Description

1.1 Intended use

The level indicator observes the filling level as a limit switch in silos
and vessels. It can be used as full, demand and empty indicator for
dusty and powdery, granulated and grainy bulk goods with a max.
grain size up to 30 mm and with a bulk density of 0.3 t/m³ ... 1.0 t/m³.

1.2 Function

The bulk goods presses with its weight against the membrane.
A tappet directly transfers the pressure from the membrane to the
micro switch. When the bulk goods are decreasing, pressure is taken
off the membrane and the switch will be interconnected.

1.3 Dimensions

M   LLET

Füllstandtechnik

GmbH

Hole-  in the vessel max. 80mm

Ø

04/13

MFA-BA 

  ©

 by MOLLET

        

      

01

Safety instructions

1.

The installation, 

2.

Comply with the local and statutory rules and regulations and/or the VDE 0100.

3.

Take notice of the temperature specifications at the data plate.

4.

A fuse (with max. 4A) has to be connected in series to the voltage supply.

5.

Protect the signal contact from voltage peaks when inductive loads are connected.

6.

The device may put into operation if it is closed, only.

7.

Switch off the power supply, before opening the device. (touchdangerous voltage)

initial operation and maintenance may be done by a qualified expert with electrical know-how only.

Read and follow these safety instructions first and take notice of the operating instructions.

MOLLET   D-74706 Osterburken  Tel.  +49  6291 6440-0  Fax  +49  6291 9846         Operating instructions

002-0200

*

1.4 Tchnical data

Manufacturer

Füllstandtechnik GmbH

Adress

Industriepark RIO 103
74706 Osterburken

Name

Membrane level indicator

Type

MFA

Temperature range

-10 °C ... +60 °C

Signal contact

change-over contact, potentialfree

Capacity of the contact

2 A  / 250 V AC

Switching voltage

24 V ... 250 V AC

or

12 V ... 65 V DC

Response delay

none

Sensitivity

20 g … 60 g adjustable

Cable connection

Flat connection 4.8x0.8

Cable entry

Cable gland M12x1.5

Type of protection

IP44

   

acc. to DIN EN 60529

Overpressure safety

up to 0.5 bar

Weight

200 g

Maintenance

none

Mounting position

any position

1.5 Materials

Housing

ABS

Membrane

Nitrile caoutchouk

MOLLET

5.2

*

LK 90

103

50

6

M12x1.5

Ø 83

T

a

Contact

IP

Membrane level indicator

MFA

Отзывы: