Tool Kit for CSP 6.3 Receptacle Terminal
Doc No: ATS-6382557HM Release Date: 07-31-12
UNCONTROLLED COPY
Page 4 of 8
Revision: A
Revision Date: 07-31-12
Figure 6
WIRE IN TERMINAL
JAWS
PARTIALLY
CLOSED
WIRE AGAINST
WIRE STOP
HANDLE
OPEN
LOCATOR
CLOSED
Figure 5
TERMINAL
PUSH HERE TO
OPEN WIRE STOP
Crimping Terminals
1.
Select the desired terminal listed in the preceding charts.
2.
Turn the Locator Lock Latch down to unlock. See Figure 3.
3.
Swing the terminal locator away from the crimp tool shown in Figure 4. Some terminals with large insulation
grips may interfere with the crimp tooling when swinging the locator into position. The terminal must then be
loaded into the locator in the closed/crimp
position. See Figure 5.
4.
Press down on the wire stop on the locator as
shown in Figure1. Insert the proper terminal
into the proper nest opening. Make sure when
choosing the nest opening, it will correspond
with the A, B or C profile on the hand tool.
5.
Return the locator to its original position.
6.
Turn the Locator Lock Latch up to lock. Make
sure that the terminal is visually centered over
the punch.
7.
Insert the proper wire over the terminal.
8.
Gently touch the wire stop with the end of the
wire. See Figure 6 and 7.
9.
Compress the terminal by squeezing the tool
handles until the ratchet mechanism cycle has
been completed. Release handles to open the
jaws.
10.
Remove the crimped terminal from the terminal locator by pressing down on the wire stop and gently pulling on
the wire. The terminal locator can be in either position.
11.
Visually inspect the crimped terminal for proper crimp location.
Note
: The tamper proof ratchet action will not release the tool until it has been fully closed.
For the Battery Power Tool:
1.
Cycle the Battery Power Tool to crimp the terminal to the wire.
2.
Remove the crimped terminal from the terminal locator by pressing down on the wire stop and gently pulling on
the wire. The terminal locator can be in either position.
3.
Visually inspect the crimped terminal for proper crimp location.
Figure 7
WIRE
INSULATION
PUNCH
CONDUCTOR ANVIL
LOCATOR
INSULATION
ANVIL
WIRES AGAINST
LOCATOR STOP
CONDUCTOR
PUNCH
TERMINAL