faults (“Emergency Stop”, “Safety Guard Open”, or
“Air Pressure Low”) will take precedence on the
display.
Screen 22
Termination Tooling not Down Fault Screen
This screen is displayed when the Termination
Tooling Cylinder fails to activate sensor B1.03 .
Check to see if the tooling jammed or if something is
stopping the cylinder from completing its stroke.
Clear the fault and press
CLEAR
button.
Air may have to be removed from the machine to
clear the fault either by pressing Emergency Stop,
opening the guard door or disconnecting the air
supply. If any of these are done their respective
faults (“Emergency Stop”, “Safety Guard Open”, or
“Air Pressure Low”) will take precedence on the
display.
Screen 23
Air Pressure Low Fault Screen
This screen is displayed when the Air Pressure
coming to the Machine is Low. Check the folowing:
1.
Factory Air Pressure is OK.
2.
Air is connected to the machine.
3.
Air Isolating Valve is turned on.
4.
Air Pressure is set to 6.0 bar (85 psi)
5.
Air Safety valve is on.
6.
Air Leaks.
Screen 30
Manual Screen #1
This screen is displayed when Manual has been
selected from the Ready to Run Screen or PREV
has been selected from the Manual #2 Screen.
Hsg Stick Feed Button:
This button allows
manual operation of the Housing Stick Feed
Cylinder. Pressing the button once will allow the
cylinder to move forward, pressing it again will
return the cylinder to the back position. The text on
the button will change between
FORWARD
and
BACK
as the button is pressed. The cylinder can
only move Forward if the Housing Cut Support is
out and can only move Back if the Housing Feed
Gripper is open.
Hsg Feed Grip Button
: This button allows manual
operation of the Housing Feed Gripper Cylinder.
Pressing the button once will allow the cylinder to
move open, pressing it again will return the cylinder
to the closed position. The text on the button will
change between
OPEN
and
CLOSE
as the button is
pressed.
NEXT
: Changes the screen to the Manual #2
Screen
SET UP
: Selects Set Up mode and changes the
screen to the Set Up #1 [Screen 40].
MAIN:
Select Automatic mode and changes the
screen to Ready to Run [Screen 2].
CLEAR
: Clears any faults.
Screen 31
Manual Screen #2