Warranty and Service

Molecular Devices is committed to ensuring the highest quality of our 

products and customer service.
If you have any problems with your GenePix

®

 4100A Microarray 

Scanner, contact our Technical Support group. In the U.S., contact us 

at 1-800-635-5577. For locations outside the United States, please 

contact your local sales representative. 

Standard Warranty 

Molecular Devices warrants its non-consumable hardware products to 

be free from defects in materials and workmanship for 12 months from 

date of invoice or date of purchased installation visit, whichever is later. 

The warranty covers the cost of parts and labor to repair the product. 
Please keep the shipping container for future use. If you require an 

additional container, one can be provided for an additional charge. 

Products returned to Molecular Devices for repair should be properly 

packaged with transportation charges prepaid. Molecular Devices will 

pay for the return shipping of the product to the customer. If the 

shipment is to a location outside the United States, the customer is 

responsible for all duties, taxes and freight clearance charges.
The warranty is valid when the product is used for its intended purpose 

and does not cover products which have been modified without 

approval from Molecular Devices, or which have been damaged by 

abuse, accident or connection to incompatible equipment.
This warranty is in lieu of all other warranties, expressed or implied.

Out-of-Warranty Repair Service

Out-of-warranty repair service is available. Contact Molecular Devices 

Technical Support for more information.

Optional Service Agreement

Purchasing an optional Service Agreement extends the coverage of the 

Standard Warranty. Contact the supplier for current rates.

GenePix_4100A.book  Page 33  Friday, October 22, 2010  3:21 PM

Содержание GenePix 4100A

Страница 1: ...GenePix 4100A Microarray Scanner User Guide 5000449 D October 2010 GenePix_4100A book Page 1 Friday October 22 2010 3 21 PM...

Страница 2: ...sage is intended only to designate those manufacturers products as supplied by Molecular Devices for incorporation into its equipment and does not imply any right and or license to use or permit other...

Страница 3: ...HAT HAVE INTELLECTUAL PROPERTY RIGHTS IN THE POTENTIAL FIELD OF APPLICATION OF THIS INSTRUMENT INCLUDE WITHOUT LIMITATION AFFYMETRIX INC AFFYMETRIX AGILENT AND OXFORD GENE TECHNOLOGY THIS INSTRUMENT H...

Страница 4: ...4 5000499 D GenePix_4100A book Page 4 Friday October 22 2010 3 21 PM...

Страница 5: ...stalling the Software 16 Turning on the Scanner 17 Inserting a Slide 17 Shutting Down the Scanner 19 Chapter 3 Maintenance and Troubleshooting 21 Moving the Scanner 22 Interlock Failure Symptoms 23 Fu...

Страница 6: ...6 5000499 D Appendix C Warranty and Service 33 Standard Warranty 33 Out of Warranty Repair Service 33 Optional Service Agreement 33 Technical Support 34 GenePix_4100A book Page 6 Friday October 22 201...

Страница 7: ...peration that can cause damage to the instrument device or data if precautions are not followed Related Documentation The customer documentation for the 4100A Microarray Scanner includes the GenePix P...

Страница 8: ...Foreword 8 5000499 D GenePix_4100A book Page 8 Friday October 22 2010 3 21 PM...

Страница 9: ...total time Scanner Features Can be configured with one or two internally installed laser excitation sources Sequential scanning of up to two wavelengths Precisely controlled automatic laser power mon...

Страница 10: ...r are Protective enclosure Optics Lasers Optical path Emission filters PMT photo multiplier tube Status lights Figure1 1 GenePix 4100A Microarray Scanner For detailed information about each component...

Страница 11: ...PMT Signal digital output 16 bit Image format Single or multi image TIFF Computer interface USB 2 0 Scan time 6 5 minutes per channel for full size scan area at 10 m resolution Dynamic range Four orde...

Страница 12: ...to 60 Hz 100 to 240 VAC 2A max Space 25 6 inches deep by 16 9 inches wide by 13 4 inches high 65 cm by 43 cm by 34 cm An additional 6 inches 15 2 cm for clearance Bench support Sufficient to support 4...

Страница 13: ...nner requires repair you must return it in the original packaging If the crate has been damaged in transit you must retain it for inspection by the carrier WARNING Shock Hazard In an emergency users m...

Страница 14: ...can cause misalignment and voids the scanner warranty 2 Lift and then place the scanner on a flat level surface away from direct sunlight dust drafts vibration and moisture Carefully move the scanner...

Страница 15: ...er 4 Plug the main power cable into the port on the back of the scanner and the lab s power outlet We recommend you use a surge protector between the main power cable and the power outlet Figure2 1 Co...

Страница 16: ...stall the GenePix Pro Software CAUTION Do not to insert the security key into the control computer until after the GenePix Pro Software has been installed 4 Install the security key For more informati...

Страница 17: ...ardware performance events into the Hardware Diagnostics Report every two hours during operation Inserting a Slide The slide holder is a precision component designed to ensure proper focusing and fiel...

Страница 18: ...g the front of the scanner Figure2 2 Slider holder Ite m Name Description 1 Slide door In raised position 2 Slide holder In load position 3 Slide Place feature side down 4 Barcode Barcode is facing th...

Страница 19: ...or 5 Close the slide door The slide holder moves into the scan position Shutting Down the Scanner Proper shutdown of the 4100A Microarray Scanner ensures the scanner or software are not damaged To shu...

Страница 20: ...Installation and Operation 20 5000499 D GenePix_4100A book Page 20 Friday October 22 2010 3 21 PM...

Страница 21: ...before returning the scanner or any components WARNING Biohazardous Material Never perform any maintenance procedures on the scanner in an environment where potentially damaging gases or liquids are p...

Страница 22: ...ties window appears 4 Click Park Scanner for Shipping A message box appears informing you that the scanner has been successfully parked CAUTION Always turn off power to the scanner using the power swi...

Страница 23: ...g below the slide after the door is opened The blue Scanning LED on the front of the scanner does not extinguish when the slide door is open The GenePix Pro Software does not recognize the scanner or...

Страница 24: ...Maintenance and Troubleshooting 24 5000499 D GenePix_4100A book Page 24 Friday October 22 2010 3 21 PM...

Страница 25: ...formance of such lasers is often sensitive to external temperature fluctuations the scanner uses an active temperature stabilization design to minimize temperature based laser fluctuations The GenePix...

Страница 26: ...ation on custom filters and their applications refer to the filter manufacturer s website Semrock Inc www semrock com Chroma Technology Corp www chroma com Custom Filters The GenePix 4100A Microarray...

Страница 27: ...e of incident light intensities However there is a very non linear relationship between the voltage of the PMT and the PMT output Therefore a slide scanned at a PMT voltage of 800 V will not be twice...

Страница 28: ...canning Eject FigureA 1 Status lights GenePix 4100A Microarray Scanner Item Name Description 1 Device standby The scanner is powered up and ready to scan a slide 2 Scanning The slide is in the load po...

Страница 29: ...sing each Y direction step from 5 m to 10 m Consequently a 10 m scan is twice as fast as a scan at 5 m and outputs the average of each adjacent pair of 5 m spots in the X direction as the value of a s...

Страница 30: ...sentation of how the 4100A Microarray Scanner samples 5 m spots and averages them to calculate the values of the image pixels for the various scan modes and pixel sizes On the left side of each image...

Страница 31: ...ain is set below this range the probability that each impinging photon will be converted to an electron is diminished and the dynamic range will be limited on the low end Above this range noise begins...

Страница 32: ...Instrument Performance Factors 32 5000499 D GenePix_4100A book Page 32 Friday October 22 2010 3 21 PM...

Страница 33: ...oducts returned to Molecular Devices for repair should be properly packaged with transportation charges prepaid Molecular Devices will pay for the return shipping of the product to the customer If the...

Страница 34: ...ur name you can then register your instrument If you require advice on the use of your GenePix 4100A Microarray Scanner do not hesitate to contact Molecular Devices Technical Support Visit the website...

Отзывы: