3.2 Performing Sensitivity Test
1
The test person breathes through the mouth, with
tongue slightly forwarded.
2
Ask the test person to indicate as soon as they taste
the Bitrex
®
.
3
Inject up to 10 full squeezes until the person being
tested indicates they can taste the Bitrex
®
.
4
If nothing is detected, repeat the procedure up to a
further 2 times.
5
If nothing is detected after 30 squeezes, the test person cannot be tested with this test
method. Please contact Moldex for information on alternative methods.
6
Note the number of squeezes required. This will determine the amount of Bitrex
®
Test
Solution used during the Fit Test.
3. Sensitivity Test
Squeeze
10x
Squeeze
10x
Squeeze
10x
Nothing
detected?
Nothing
detected?
Nothing
detected?
Test is not
applicable.
Detected?
Note 10
Detected?
Note 20
Detected?
Note 30
|
10