5.18 Support Bushing Installation for Systems
with MasterSHIELD
WARNING
Make sure the lifting eyebolt, chain and crane can support the weight of the
manifold. Failure to do so may cause serious injury.
For systems with MasterSHIELD, support bushings are used for non-valved
systems. See Figure 5-34.
Figure 5-34 Support bushing for systems with MasterSHIELD
IMPORTANT
Support bushings are supplied to final dimensions. No final grinding is
required. Refer to the General Assembly drawing for more information.
1. Install the manifold into the plate and ensure that it sits on the nozzles.
2. Use the General Assembly drawings to locate the positions for the
support bushings.
3. Use a dowel pin to install all of the support bushings into the manifold.
Nozzle
Manifold
plate
Support
bushing
Figure 5-35 Support bushing in MasterSHIELD systems
5-42
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
ASSEMBLY
Hot Runner User Manual