5.17 Connect Solenoid Valve Bank
5.17.1 Hydraulic Valvebank Connection
1. If any of the provided hoses are longer than required then you must
cut them to length and crimp the end onto the port union. Attach an
appropriate label to show gate number (Gxx) and Open or Close function.
2. Prepare crimped hose with labeling and arrange the control layout to the
solenoid valve bank.
3.
Connect the hydraulic hose with the first white label “G1 CLOSE” to the
port on the top of the cylinder.
White “G1 Close” hoses go
to the upper ports
4. Route the hose on top of the wire channel and secure with high
temperature cable ties.
5. Connect the other end of the hose to the designated valve-unit port. On
the Bosch Rexroth solenoid valve bank:
“B” port = CLOSE,
“A” port = OPEN
6. Continue to attach all subsequent CLOSE hoses (G2, G3, etc.).
7. Similarly, connect the return hoses starting with white “G1 OPEN” label
from the lower port on cylinder body to the same solenoid valve unit.
White “G1 Open” hoses
go to the lower ports
5-50
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
ASSEMBLY
FSG2 User Manual